• 제목/요약/키워드: Series transformer

검색결과 349건 처리시간 0.031초

고효율 LLC 직렬공진 컨버터 (A High Efficiency LLC Series Resonant Converter)

  • 강성인;윤광호;김은수;박준호;임대호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.424-427
    • /
    • 2007
  • The LLC series resonant converter with a LLT (Inductor-Inductor-Transformer) transformer for PDP power supply is presented. LLT transformer used to combine the inductor and transformer into one unit has the increased leakage inductance in the primary and secondary due to the winding method and the use of the gaped core. The increased leakage inductance in the primary and secondary of LLT transformer can be impacted on the DC voltage gain characteristics of LLC series resonant converter. In this paper, DC gain characteristics and the experimental results of the LLC series resonant converter with a LLT transformer are verified on the Math-CAD simulation based on the theoretical analysis and the 600W experimental prototype.

  • PDF

Series Resonant ZCS- PFM DC-DC Converter using High Frequency Transformer Parasitic Inductive Components and Lossless Inductive Snubber for High Power Microwave Generator

  • Kwon, Soon-Kurl;Saha, Bishwajit;Mun, Sang-Pil;Nishimura, Kazunori;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.18-25
    • /
    • 2009
  • Conventional series-resonant pulse frequency modulation controlled DC-DC high power converters with a high-frequency transformer link which is designed for driving the high power microwave generator has the problem of hard switching commutation at turn-on and turn-off of active power switching devices. This problem is due to the influence of the magnetizing current of the high-frequency transformer. This paper presents a novel prototype for a high-frequency transformer using parasitic parameters with a lossless inductive snubber and a series resonant capacitor assisted series-resonant zero current switching pulse frequency modulated DC-DC power converter, which is designed using a high power magnetron for microwave ovens. In order to implement a complete and efficient soft switching commutation, the performance of the new converter topology is practically confirmed and evaluated in the prototype of a power microwave generator.

LLC 직렬공진 컨버터 동작특성 (Operating Characteristics of LLC Series Resonant Converter)

  • 강성인;윤광호;박준호;허동영;김은수
    • 전력전자학회논문지
    • /
    • 제12권6호
    • /
    • pp.472-482
    • /
    • 2007
  • 본 논문에서는 PDP TV 전원에 적용된 LLT 변압기를 사용한 LLC 직렬공진 컨버터의 설계과정과 실험결과에 대해 서술하였다. 인덕터와 변압기를 하나의 변압기로 사용한 LLT 변압기는 전선방법과 코어의 공극에 따라 1, 2 차측 누설인덕턴스가 함께 증가한다. 이러한 LLT 변압기의 증가된 1, 2차측 누설인덕턴스는 LLC 직렬공진컨버터의 DC 전압이득에 영향을 준다. 따라서 본 논문에서는 LLT 변압기 적용 LLC 직렬 공진 컨버터의 전압이득 특성과 실험 결과에 대해 Math-CAD 시뮬레이션을 기본으로 한 이론적인 해석 및 600W 시제품을 통해 증명하였다.

PDP의 유지 전원을 위한 고효율 LLC 직렬 공진컨버터 (A High Efficiency LLC Series Resonant Converter for PDP Sustaining Power Supply)

  • 이현관;이기식;강성인;공영수;김은수;임대호;허동영;장병철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.46-49
    • /
    • 2006
  • The LLC series resonant converter with a LLT(Inductor-Inductor-Transformer) transformer for PDP V sustaining power supply is presented. LLT transformer used to combine the inductor and transformer into one unit has the increased leakage inductance in the primary and secondary due to the winding method and the use of the gaped core. The increased leakage inductance in the primary and secondary of LLT transformer can be impacted on the DC voltage gain characteristics of LLC series resonant converter. In this paper, DC gain characteristics and the experimental results of the LLC series resonant converter with a LLT transformer are verified on the simulation based on the theoretical analysis and the 400W experimental prototype.

  • PDF

낮은 커플링 변압기를 갖는 비접촉 전원의 개선된 고효율 공진 컨버터 (An Improved High Efficiency Resonant Converter for the Contactless Power Supply with a Low Coupling Transformer)

  • 공영수;김은수;이현관
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권1호
    • /
    • pp.33-39
    • /
    • 2005
  • Comparing with the conventional transformer without the air gap, a contactless transformer with the large air gap between the long primary winding and the secondary winding has increased leakage inductance and reduced magnetizing inductance. For transferring the primary power to the secondary one, the high frequency series resonant converter has been widely used for the contactless power supply system with the large air gap and the increased leakage inductance of the contactless transformer However, the high frequency series resonant converter has the disadvantages of the low efficiency and high voltage gain characteristics in the overall load range due to the large air gap and the circulating magnetizing current. In this paper, the characteristics of the high efficiency and unit voltage gain are revealed in the proposed three-level series-parallel resonant converter. The results are verified on the simulation based on the theoretical analysis and the 5kW experimental prototype.

Grid-friendly Control Strategy with Dual Primary-Side Series-Connected Winding Transformers

  • Shang, Jing;Nian, Xiaohong;Chen, Tao;Ma, Zhenyu
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.960-969
    • /
    • 2016
  • High-power three-level voltage-source converters are widely utilized in high-performance AC drive systems. In several ultra-power instances, the harmonics on the grid side should be reduced through multiple rectifications. A combined harmonic elimination method that includes a dual primary-side series-connected winding transformer and selective harmonic elimination pulse-width modulation is proposed to eliminate low-order current harmonics on the primary and secondary sides of transformers. Through an analysis of the harmonic influence caused by dead time and DC magnetic bias, a synthetic compensation control strategy is presented to minimize the grid-side harmonics in the dual primary side series-connected winding transformer application. Both simulation and experimental results demonstrate that the proposed control strategy can significantly reduce the converter input current harmonics and eliminates the DC magnetic bias in the transformer.

비접촉 전원장치의 비접촉 커플러 설계 (Non contact Coupler Design in Non contact Power Supply)

  • 류명효;차헌녕;백주원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1500-1502
    • /
    • 2005
  • In this paper, the electrical characteristics of the non-contact transformer is presented using conventional coupled inductor theory. Each non-contact transformer is analyzed through simulation and measurement. In high power applications, non-contact transformer is so bulky and heavy that it should be split by some light transformers. So non-contact transformer needs several small transformer modules which are connected series or parallel to transfer the primary power to the secondary one. This paper shows analytic result of the each non-contact transformer module and comparison result between series-connection and parallel-connection of the non-contact transformer. The results are verified on the simulation based on the theoretical analysis and the 30kW experimental prototype.

  • PDF

변압기 직렬구조의 EV용 승압형 양방향 ZCS DC/DC 컨버터 개발 (Development of Boost Type Bidirectional ZCS DC/DC Converter For EV of Transformer Series Construction)

  • 최정식;박병철;정동화;송성근
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.37-46
    • /
    • 2013
  • This paper proposes the boost type bidirectional zero current switching(ZCS) DC/DC converter of transformer series construction for electric vehicle operation using low voltage battery. This converter can high boost through the double voltage circuit and series construction of output part using two converters. This converter system has the advantages that bidirectional power transfer is excellent, size and making of transformer because of this converter keeps the transformation ratio to 1:1. Proposed DC/DC converter uses the ZCS method to decrease the switching loss. By replacing reactance ingredients of L-C resonance circuit for ZCS with leakage inductance ingredients of high frequency transformer and half-bridge capacitor it reduces system size and expense because of not add special reactor. It can confirm to output of high voltage to operate the electric vehicle with low voltage of input and operation of ZCS in all load region through the result of PSIM simulation and experiment.

LLT 변압기 적용 LLC 직렬공진컨버터 동작특성 (Operating Characteristics of LLC Series Resonant Converter Using A LLT Transformer)

  • 이현관;허동영;이기식;정봉근;강성인;김은수
    • 전력전자학회논문지
    • /
    • 제11권5호
    • /
    • pp.409-416
    • /
    • 2006
  • LLT 변압기 적용 LLC 직렬공진컨버터의 동작특성에 대해 설명하였다. 본 논문에서는 1차측 권선과 2차측 권선을 분리하고, 변압기 중간에 공극(Air-Gap)을 삽입한 일체화된 LLT 변압기를 적용하였다. 이와 같이 적용된 LLT 변압기의 경우 1차측 누설인덕턴스만이 증가되는 것이 아니고 2차측 누설인덕턴스 또한 증가되게 된다. 이렇게 증가된 2차측 누설인덕턴스는 전압이득 특성곡선에 있어 LLC 직렬공진컨버터에 적용한 변압기를 사용한 경우보다 전체적으로 높은 전압이득 특성을 가지게 된다. 따라서 본 논문에서는 2차측 누설인덕턴스를 고려한 일체화된 LLT 변압기적용 LLC 직렬공진컨버터에 대해 이론적으로 해석하고 시뮬레이션 하였으며, 400W급 시제품을 제작하여 실험한 결과에 대해 서술하였다.

Analysis of the Contactless Power Transfer System Using Modeling and Analysis of the Contactless Transformer

  • Ryu Myung-Hyo;Kim Jong-Hyun;Baek Ju-Won;Cha Hon-Nyong
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.351-358
    • /
    • 2006
  • In this paper, the electrical characteristics of the contactless transformer is presented using the conventional coupled inductor theory. Compared with the conventional transformer, the contactless transformer has a large airgap, long primary wire and multi-secondary wire. As such, the contactless transformer has a large leakage inductance, small magnetizing inductance and poor coupling coefficient. Therefore, large magnetizing currents flow through the entire primary system due to small magnetizing inductance, resulting in low overall system efficiency. In high power applications, the contactless transformer is so bulky and heavy that it needs to be split by some light and small transformers. So, the contactless transformer needs several small transformer modules that are connected in series or parallel to transfer the primary power to the secondary one. This paper shows the analysis and measurement results of each contactless transformer module and comparison results between the series- and parallel-connection of the contactless transformer. The results are verified on the simulation based on the theoretical analysis and the 30kW experimental prototype.