• 제목/요약/키워드: Shield gas

검색결과 106건 처리시간 0.036초

Nd:YAG 레이저를 이용한 냉연강판과 스테인레스강판의 용접 (A Study of Nd:YAG Laser Welding in Cold-reduced Carbon Steel and Stainless Steel Sheet)

  • 이철구;이우람;백운학
    • 한국생산제조학회지
    • /
    • 제19권2호
    • /
    • pp.163-170
    • /
    • 2010
  • We have studied on welding dissimilar materials of cold-reduced carbon steel sheet and stainless steel sheet together by using laser beam. It is well known that stainless steel is so strong againt rust and heat, while cold-reduced carbon steel is widely used in various parts of industry. In this research we have performed some experiments to know the possibility of welding dissimilar materials using laser beam by adjusting the power output of 3kW laser. Other conditions of the experiments were as follows : the welding speed was varied in the range between 2m/min and 7m/min, argon gas and helium gas were used as shield gas, the flow value of shield gas was ranged between $10{\ell}/min$ and $30{\ell}/min$, and the gap of two materials was ranged between 0mm and 0.3mm. In order to ascertain of the welded surface, we have done the tensile strength testing, the hardness testing and the microscope observation. As a result, we have found that tensile strength was the highest at the condition of the welding speed of 4, the flow value of $20{\ell}/min$, the gap of two materials 0, and the use of helium gas. Above testings have also showed that the tensile strength was generally satisfactory since the penetration of welding was almost complete due to the thinness of the materials. In addition, the formation of the welded area was excellent when it had the highest tensile strength.

가스 절연 시험용 체임버 개발 연구 (A Study on the Development of a 1800KV Testing Chamber for Gas Insulation)

  • 조연옥;최병주;김광수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.405-408
    • /
    • 1989
  • A 1800KV testing chamber for gas insulation has been developed. To develop the chamber, all parts consisting of the chamber, namely, bushing, main chamber, shield, conductor bus, inspection window, feedthrough, and spacer have been designed based on numerical electric field analysis. This paper presents the detailed design philosophy and methods of the chamber.

  • PDF

LNG 벙커링용 이중 단열적용 LNG 저장탱크 열해석 (Thermal Analysis on the LNG Storage Tank of LNG Bunkering System Applied with Double Shield Insulation Method)

  • 정일영;김남국;윤상국
    • 한국가스학회지
    • /
    • 제22권4호
    • /
    • pp.1-6
    • /
    • 2018
  • IMO에서 규정하는 LNG 벙커링 선박용 연료 탱크 중 C형 가압탱크는 내외 2중 용기로 구성된 초저온 탱크에 $10^{-2}$ Torr 진공과 펄라이트 단열재가 충전되는 것이다. 그러나 이 단열방식은 LNG 기화량이 하루당 2.0 % 내외로 증발율이 커서 보다 단열효과가 좋은 탱크가 요구되어 진다. 본 연구에서는 내외탱크 사이에 고진공을 적용하고 외부탱크의 내벽체에 중간 단열로 펄라이트 진공단열을 적용하는 단열 방식을 새로이 고안하여 열해석을 수행하였다. 이의 장점으로는 진공 공간의 감소로 고진공 형성 시간을 크게 감소되고, 진공도 $10^{-4}$ Torr 이하에서 하루당 증발율이 0.16 %에 불과한 매우 효율이 높은 탱크 단열방식이 되었다. 만약 현재의 IMO C형 탱크의 진공펄라이트 단열에서 진공이 파괴되는 경우, C형 탱크는 하루당 4.9 %의 증발이 발생하고 새 고안 탱크는 5.23 %로 거의 동일하게 된다.

A Study of the 3D Unmanned Remote Surveying for the Curved Semi-Shield Tunneling

  • Lee, Jin-Yi;Jun, Jong-Woo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1791-1796
    • /
    • 2005
  • Semi-shield tunneling is one of the propulsion construction methods used to lay pipes underground between two pits named 'entrance' and 'destination', respectively. Usually a simple composition, such as 'a fiducial target at the entrance+a total station (TS)+a target on the machine', is used to confirm the planned course. However, unavoidable curved sections are present in small-sized pipe lines, which are laid after implementation of a road system, for public works such as waterworks, sewer, electrical power, and gas and communication networks. Therefore, if the planned course has a curved section, it is difficult to survey the course with the abovementioned simple composition. This difficulty could be solved by using the multiple total stations (MTS), which attaches the cross type linear LED target to oneself. The MTS are disposed to where each TS can detect the LED target at the other TS or the base point or the machine. And the accurate relative positions between each MTS and target are calculated from measured data. This research proposes the relative and absolute coordinate calculation algorithm by using three MTS to measure a curved course with 20m curvature at 30m maximum distance, and verifies the algorithm experimentally.

  • PDF

KSTAR TOKAMAK의 열차폐막 설계 (The Design of Thermal Shield for KSTAR TOKAMAK)

  • 김동락;노영미;허남일;조승연;육종설;안귀천;도철진;권면;이경수;윤병주
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.45-47
    • /
    • 2001
  • The function of the thermal shield(TS) is to eliminate the thermal radiation from the room temperature side to the coil temperature(4.5K) region so as to reduce the thermal load on the He refrigerator. The TS is composed of multilayer insulation(MLI) which is coated very thin aluminum on the insulating material, cryopanel which is cooled by cold gaseous He, and supports which stand the cryopanel and MLI on the room temperature part. The thermal shield for the TF coils and PF coils has been located between the coils and vacuum vessel. The thermal shielding cryopanel is cooled under 80 K by a forced flow of helium gas using cooling pipes on the cryopanel.

  • PDF

Technology Research on Gas Turbine Combustor Utilizing Melt-Growth Composite Ceramics

  • Konoshita, Yasuhiro;Hagari, Tomoko;Matsumotoi, Kiyoshi;Ogata, Hideki;Ishida, Katsuhiko
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.854-860
    • /
    • 2004
  • "Research and Development of Melt-Growth Composite (MGC) Ultra High Efficiency Gas Turbine System Technology" program has been started in JFY2001. The main objective of the program is to establish basic component technologies to apply MGC material to an efficient gas turbine system successfully. It is known that MGC material maintains its mechanical strength at room temperature up to about 2000 K, which is ideal for the high temperature gas turbine. The purposes of the present study are to develop the cooling structure of the gas turbine combustor liner where MGC material is applied as the heat shield panel, also to develop the low NOx combustion system for a 1970 K (1700 deg.C) class gas turbine combustor. To start with, basic heat transfer characteristics were investigated by one-dimensional calculation and heat transfer experiment for the cooling structure. Axially staged configuration and fuel preparation were investigated by CFD calculation and experiments for the low NOx combustor.

  • PDF

해저 연약 퇴적층 지반 쉴드 TBM 위험요인 평가 및 장비 침하에 관한 연구 (A study on the risk and settlement evaluation of a shield TBM excavated in soft marine sedimentary soils)

  • 유광호;박치면
    • 한국터널지하공간학회 논문집
    • /
    • 제18권4호
    • /
    • pp.355-364
    • /
    • 2016
  • 최근 우리나라 서해안 산업단지의 폐열과 증기의 재활용을 위한 운송관로 수용목적으로 해저 퇴적층 지반에 3.25km의 해저터널이 쉴드 TBM으로 시공 완료되었다. 쉴드 TBM 터널은 지반조건 및 시공요인에 기인한 불확실성으로 인해 장비 침하 등 많은 위험요인을 겪게 되는데 터널 시공 중 쉴드 TBM 장비 침하로 인한 선형이탈이 발생하였으며 원인 분석결과 지지력이 부족한 연약한 점토층 지반조건이 주원인으로 작용한 것으로 검토되었다. 본 연구에서는 지반조건을 고려한 위험요인을 평가하고, 지지력을 고려한 이론식과 TBM 굴진조건 즉, 동적조건을 구현할 수 있는 3차원 수치해석을 통해 장비 침하 및 쉴드 TBM 굴진속도와의 상관관계에 대한 검토를 수행하였다. 연약한 점토층 지반에서 지지력 부족으로 쉴드 TBM 장비 침하가 발생할 수 있으며, 이를 방지하기 위해서는 지반특성에 적합한 최적 굴진속도의 적용이 필요한 것으로 검토되었으며 본 검토 대상구간 지반조건에서는 쉴드 TBM 굴진속도를 35~40 mm/min로 유지하는 경우에 장비 침하를 방지할 수 있는 것으로 검토되었다.

해외 쉴드TBM 입찰안내서 분석을 통한 국내 발주 기준 정립에 관한 연구 (A study on the establishment of domestic criteria through analysis of shield TBM requirements in overseas ITB (Invitation to Bid))

  • 김기환;김혁;문철화;김용휴;김동호;이재용
    • 한국터널지하공간학회 논문집
    • /
    • 제19권6호
    • /
    • pp.985-997
    • /
    • 2017
  • 해외에서는 이미 많은 국가에서 대부분의 터널공사가 쉴드TBM공법으로 발주되고 있으며, 국내 기업도 활발하게 참여하여 수행하고 있는 실정이다. 국내의 경우는 재활용 장비를 활용한 전력구, 가스관로, 상하수도 공사를 중심으로, 지하철 터널의 경우는 신규장비를 활용한 7 m 이상의 쉴드TBM공법이 주로 발주되고 있다. 쉴드TBM은 한번 제작되면 변경하기 쉽지 않으므로, 해당 공사의 다양한 특성을 만족하도록 제작조건에 대해 충분한 정보를 발주자가 제공할 필요가 있다. 본 연구는 먼저 최적의 쉴드TBM 제작을 위해 최근 홍콩과 영국에서 발주된 도심지 터널공사의 입찰안내서에서 제시한 제반 조건들을 검토하고, 국내의 입찰안내서와 비교분석하였다. 이러한 분석결과는 향후 국내에서 쉴드TBM을 이용하여 터널공사를 수행하고자 하는 경우, 입찰 및 제작에 대한 보다 발전된 가이드라인을 제공할 수 있을 것으로 기대된다.

차량진동에 대한 노출가스관의 방진 시스템 개발을 위한 실험적 연구 (An Experimental Study on Isolation System of Aerial Gas Pipeline for Vehicle Vibration)

  • 박연수;강성후;박선주
    • 한국소음진동공학회논문집
    • /
    • 제11권5호
    • /
    • pp.131-139
    • /
    • 2001
  • In this paper, aerials gas pipeline vibrations due to the passing of vehicles have been measured, and peak values and characteristics of vibration were analyzed. In order to develop isolation system for gas pipeline, six cases with various support condition and hanging method were tested. The hanger used instead of wore rope isolated almost all vibrations transmitted from main beam. In the results of test, we could decrease response of vibration velocity from 49 % to 56 % and response of vertical vibration acceleration from 49 % to 60 %, because hanger instead of wire rope was used and rubber pads instead of wooden shield plates at support positions for Proofing horizontal vibration were used.

  • PDF