• 제목/요약/키워드: Shielded twisted pair cable

검색결과 5건 처리시간 0.016초

Analysis of Shielded Twisted Pair Cable to External Field Coupling by Expanded Chain Matrix Modeling

  • Cho, Yong-Sun;Jung, Hyun-Kyo;Cheon, Changyul;Chung, Young-Seek
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2049-2057
    • /
    • 2014
  • In this paper, a numerical method for analyzing coupling between high-altitude electromagnetic pulse (HEMP) as external field and a shielded twisted pair (STP) cable is proposed, which is based on an expanded chain matrix. Load responses of electromagnetic (EM) field excitation in uniform transmission line (TL) are solved by Baum-Liu-Tesche (BLT) equations in frequency domain, however, it is difficult to apply BLT equations to solve load responses of STP cable because the iteratively changing configuration of each twisted pairs are involved in cable. To avoid this problem and decrease memory and CPU time, we proposed the expanded chain matrix modeling method that is calculated using ABCD parameters, and applied multi-conductor transmission line (MTL) theory to consider the EMP coupling effectiveness of each twisted pairs. The results implemented by the proposed method are presented and compared with those obtained by the finite-difference time domain (FDTD) method as a kind of 3D full wave analysis.

FDTD Analsysis of Lightning-Induced Voltages on Shielded Telecommunication Cable with Multipoint Grounding

  • Ju, Jae-Cheol;Lee, Hyun-Young;Park, Dong-Chul;Chung, Nak-Sam
    • Journal of electromagnetic engineering and science
    • /
    • 제1권1호
    • /
    • pp.88-94
    • /
    • 2001
  • In this paper, the lightning-induced voltages on shielded twisted-pair wires with multipoint grounding on cable sheath are calculated by using finite-difference time domain (FDTD) method. The equivalent single-wire line that represents a bundle of twisted-pair wires is adopted for computational efficiency. A finitely conducting ground is also taken into account in both lightning electromagnetic field calculations and surge propagation along the shielded cable for a practical simulation. It is found that multipoint additional grounding on cable sheath provides more shielding effectiveness especially in the early time response of the lightning-induced voltages. From this study, the requirements for lighting surge protection devices in a telecommunication subscriber cab1e can be established.

  • PDF

케이블 공진을 이용한 600V 제어/계측용 꼬임쌍선 차폐 케이블의 열화상태 진단에 대한 연구 (A Study on the Deterioration Diagnosis of 600V Shielded Twisted Pair Control/Measurement Cable using Resonance Frequency)

  • 신재영;김광호;나완수
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1768-1775
    • /
    • 2015
  • Recent major domestic facilities, such as nuclear power plants, many control cables are installed and are degraded by long-term use, but research on deterioration diagnosis is lacking. In the event of a fault in the cable due to deterioration can be developed into a major accident such as the main plant is stopped, so the deterioration diagnostic techniques of high reliability for the cable is required. In this paper, proposes a methodology using a cable resonance that can effectively diagnose the deterioration of the cable. Prior to the test, we developed a setup for stable measuring the characteristics of the cable and it verified the suitable of the measurement set-up in terms of interactivity and reliability, also measured S-parameters applying verified measurement set-up to the cables that deterioration degree is different. Then, we had amplified the difference in resonance frequency between the healthy state and the deteriorated state using connection in a series of measured S-parameters. In a result from the method, we have verified that the more deteriorate the cables is, the more decrease the resonance frequency is. Measured results are justified by inducing the resonance frequency calculation of the cable from the S- parameters represented by the hyperbolic function formula. VNA(Vector Network Analyzer) for S-parameter measurements used in this study is Agilent E5061B and shielded twisted-pair cables was used for deterioration diagnostic test.

디지털 제어장치의 고출력 전자기펄스에 대한 취약성 사례 분석 (Vulnerability Case Analysis of the High Power Electromagnetic Pulse on Digital Control System)

  • 우정민;주문노;이홍식;강성만;최승규;이재복
    • 한국전자파학회논문지
    • /
    • 제28권9호
    • /
    • pp.698-706
    • /
    • 2017
  • 디지털 제어 시스템에서 주로 사용되는 설비인 PLC(Programmable Logic Controller)와 통신선로에 대한 HPEM(High Power Electromagnetic) 펄스의 노출 위험이 최근 증가되고 있다. 본 연구에서는 서로 다른 주파수 대역을 가지는 HPEM 발생장치를 이용하여 분리된 독립 객체로써 전자 장치의 HPEM에 대한 취약성을 평가하였다. 전자장치가 어떠한 영향을 받는지 상황별로 나누어 비교하였고, HPEM에 노출된 피 시험 기기의 취약성을 분석하였다. 피 시험 기기는 특정 이상의 HPEM에 노출되면, 제어 장치의 전압 및 통신 파형에 왜곡된 특성을 보였으며, UTP(Unshielded Twisted Pair) 케이블에 연결된 장치는 유도전압에 의해 작동 불량을 나타났다. 그러나 FTP(Foiled Twisted Pair) 케이블에 연결된 장치인 경우에는 HPEM 노출로부터 효율적으로 보호되었다. 따라서 현재 전력설비 및 산업현장에서 이용되고 있는 디지털 제어시스템에 대한 HPEM 노출 취약성과 보호대책의 필요성을 입증하였다.

Analog Adaptive Pulse shaping and Line Equalizer For 400Mb/s data rate on 50m STP Cable

  • Lee, Hoon;Kwisung Yoo;Gunhee Han
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.887-890
    • /
    • 2003
  • High Speed data transmission over a long length of cable is limited due to the limited bandwidth of a cable which introduces ISI(Inter Symbol Interference). In order to compensate for the loss and phase dispersion in the cable, a pulse shaping in a transmitter and a line equalizer in receiver can be used. This paper presents a low-power and small-ana analog adaptive pulse shaping circuit and line equalizer, The design was fabricated in a 0.25${\mu}{\textrm}{m}$ mixed-signal CMOS process. The proposed pulse shaping circuit and equalizer operate at 400Mb/s on 50m STP(Shielded Twisted Pair) cable. It consumes 28.5${\mu}{\textrm}{m}$ with a 2.5-V power supply and occupies only 0.098 $\textrm{mm}^2$.

  • PDF