• Title/Summary/Keyword: Shopping center in underground passage

Search Result 6, Processing Time 0.028 seconds

Universal Design in Main Entrance Space of Underground Passage Shopping Center (지하도상가 주출입 공간의 유니버설 디자인 적용 현황에 관한 연구)

  • Lee, Hyo-Chang;Ha, Mi-Kyoung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.11a
    • /
    • pp.99-102
    • /
    • 2007
  • Underground passage shopping center which is one of the underground space is a public facility. Therefore, underground passage shopping center needs physical environment that everyone (such as ordinary adults, seniors, disabled and ETC) could use it without any difficulties. The purpose of this research is to evaluate the application of universal design into main entrance space of underground passage shopping center. The scope of this research was adjusted as 8 underground passage shopping centers that are located in Seoul. Spacial scope of the research was set as public space such as main entrance space, slope way, stairway of underground passage shopping center and the content of scope of this research was the application of universal design. The conclusion of this research is as following. First, public space of underground passage shopping center needs physical environmental improvement for the convenient usage for seniors and disabled. Second, the application of universal design is needed for public space for shelter and rescue of underground passage shopping center. Third, Underground passage shopping center needs a plan to minimize the safety infringement of user by commercial activity of stores in it.

  • PDF

An Experimental Study on the Heating Characteristics of HVAC Systems for Shopping Center in Underground Passage (지하도 상가 냉난방.환기 시스템의 난방운전 특성 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju;Kim, Tae-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2989-2994
    • /
    • 2008
  • The shopping center in underground passage for efficient space utilization is increased in urban area. This study describes operation characteristics of HVAC systems with ventilation and individual heating and cooling unit for shopping center in underground passage. In order to compare energy saving, thermal environment and installation space, etc., an integrated simulator with heat production and distribution system was designed and constructed. Energy delivery efficiency is improved over 20%, and energy saving of the hybrid system is calculated as over 30% compared to conventional all air type in the case of heating. And also the results showed that humidity decreased about $5{\sim}6%$, also characteristics of thermal control is improved over 34%.

  • PDF

An Experimental Study on the Operating Characteristics with HVAC Type of Shopping Center in Underground Passage (지하도상가의 HVAC 구성방식에 따른 운전특성 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.76-81
    • /
    • 2007
  • The shopping center in underground passage increased for efficient space utilization in urban area. This study describes operation characteristics of all air type and hybrid type with local ventilation and fan coil unit fixed to ceiling. In order to compare energy saving, thermal environment and installation space, etc., integrated simulator with heat production and indoor distribution system is designed and constructed. Energy saving of the hybrid system is calculated as over 30% compared to conventional all air type. And also the results showed that humidity decreased about 6%, also indoor thermal distribution is improved as temperature variation of around $1^{\circ}C$.

  • PDF

A Study on the Promotion of Plaza in Underground Passage Shopping Centers : Focused on underground shoppping center connecting with subway station in Suwon (지하도상가 활성화를 위한 이용자 인식에 관한 연구 : 수원시 지하철역 연계 지하도상가를 중심으로)

  • You, Hak-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.3
    • /
    • pp.33-38
    • /
    • 2011
  • This study is find out the how promotion is handled by understanding the notion and the characteristics of the underpass market in the underground space by comparing those of other ours. However, the underpass market of suwon needs to remodeling. Most of all, there are problems on not having enough ensured environment.

A Case Study of Hybrid Air Conditioning and Ventilation System (환기 병용형 냉난방 시스템 설계 및 현장 적용 사례 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju;Shin, Hyun-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.89-94
    • /
    • 2008
  • In this study it was evaluated that hybrid air conditioning and ventilation system to reduce energy consumption and keep on comfortable indoor environment in an underground shopping center. Room temperature by hybrid HAVC system was controled as $1.8{\sim}2.1^{\circ}C$ low and indoor humidity was controled as $4.1{\sim}5.0%RH$ low, and response was fast in $2.0{\sim}2.5$ times compared with conventional system. And also transportation efficiency of hybrid HVAC system was improved in about 27%, and total energy consumption rate of hybrid HVAC system is decreased in 16% compared with conventional system.

  • PDF

Concentration of $NO_2$ and $SO_2$ of Underground Shopping Center in Chonan City (천안시내 지하상가의 이산화질소 및 이산화황 농도)

  • 손부순;장봉기
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.1
    • /
    • pp.102-108
    • /
    • 2000
  • Seasonal variation of $NO_2$ and $SO_2$ concentration was investigated at the underground shopping center in Chonan from October 1997 to August 1998. $NO_2$ and $SO_2$ was collected by personal air sampler at $0.4{\ell}/min$ and $0.5{\ell}/min$ respectively and analyzed using UV spectrophotometer at 550nm and 548nm individually. The results were as follows. 1. The concentration of $NO_2$ was 0.070 ppm in spring, 0.068 ppm in summer, 0.074 ppm in autumn and 0.085 ppm in winter. There was no significant difference. 2. The concentration of $SO_2$ was 0.0233 ppm in spring, 0.0216 ppm in summer, 0.0188 ppm in autumn and 0.0621 ppm in winter. There was significant difference (p<0.01). 3. The higher concentration of $NO_2$ and $SO_2$ gases were shown near the cafeteria (p<0.001, p<0.05). 4. The higher concentration of $NO_2$ was observed at indoor than the underground passage. There was significant difference between two values (p<0.01).

  • PDF