• Title/Summary/Keyword: Short Stub

Search Result 62, Processing Time 0.026 seconds

On-chip ESD protection design by using short-circuited stub for RF applications (Short-Circuited Stub를 이용한 RF회로에서의 정전기 방지)

  • 박창근;염기수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.288-292
    • /
    • 2002
  • We propose the new type of on-chip ESD protection method for RF applications. By using the properties of RF circuits, we can use the short-circuited stub as ESD protection device in front of the DC blocking capacitor Specially, we can use short-circuited stub as the portion of the matching circuit so to reduce the and various parameters of the transmission line. This new type ESD protection method is very different from the conventional ESD protection method. With the new type ESD protection method, we remove the parasitic capacitance of ESD protection device which degrade the performance of core circuit.

  • PDF

Mechanical behavior of outer square inner circular concrete-filled dual steel tubular stub columns

  • Ding, Fa-xing;Wang, Wenjun;Liu, Xue-mei;Wang, Liping;Sun, Yi
    • Steel and Composite Structures
    • /
    • v.38 no.3
    • /
    • pp.305-317
    • /
    • 2021
  • The mechanical behavior of the outer square inner circular concrete-filled dual steel tubular (SCCFT) stub columns under axial compression is investigated by means of experimental research, numerical analysis and theoretical investigation. Parameters such as diameter ratio, concrete strength and steel ratio were discussed to identify their influence on the mechanical properties of SCCFT short columns on the basis of the experimental investigation of seven SCCFT short columns. By establishing a finite element model, nonlinear analysis was performed to discuss the longitudinal and transverse stress of the dual steel tubes. The longitudinal stress characteristics of the core and sandwich concrete were also analyzed. Furthermore, the failure sequence was illustrated and the reasonable cross-section composition of SCCFT stub column was proposed. A formula to predict the axial load capacity of SCCFT stub column was advanced and verified by the results from experiment and the finite element.

Design and fabrication of power detector for multi-band six-port direct conversion method (다중대역 6단자 직접변환 방식을 위한 전력 검파기 설계 및 제작)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2194-2200
    • /
    • 2010
  • In this paper, the power detectors using metamaterials were designed and fabricated for multi-band six-port direct conversion method. The RF short-stubs for power detector were designed by using metamaterials which provide multi-band characteristics. The power detectors with metamaterial RF short-stub were analyzed and fabricated by using lumped and distributed element. The measured results of metamaterial power detectors show the good agreement with the simulation results. The performance of lumped-metamaterial RF short-stub shows the insertion loss below 1 dB and the good frequency response characteristics. Also, the distributed-metamaterial RF short-stub shows the good frequency response characteristics and the insertion loss under that of lumped-metamaterial RF short-stub. The multi-band power detectors with metamaterial RF short-stub detect the input RF signal in the designed dual frequency bands very well.

CPW Phase Shifter and Shunt Stub with Air-Bridge Fabricated on Oxidized Porous Silicon(OPS) Substrate (산화된 다공질 실리콘 기판 위에 제작된 에어브리지를 가진 CPW Phase Shifter와 Shunt Stub)

  • Sim, Jun-Hwan;Park, Dong-Kook;Kang, In-Ho;Kwon, Jae-Woo;Park, Jeong-Yong;Lee, Jong-Hyun;Jeon, Joong-Sung;Ye, Byeong-Duck
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.9
    • /
    • pp.11-18
    • /
    • 2002
  • This paper presents a CPW phase shifter and shunt stub with air-bridge on a 10-${\mu}m$-thick oxidized porous silicon(OPS) substrate using surface micromachining. The line dimensions of the CPW phase shifter was designed with S-W-Sg = 100-30-400 ${\mu}m$. And the width and length of the air-bridge with "ㄷ“ shape were 100 ${\mu}m$ and 400-460-400 ${\mu}m$, respectively. In order to achieve low attenuation, stepped air-bridge CPW phase shift was proposed. The insertion loss of the stepped air-bridge CPW phase shift is more improved than that of no stepped air-bridge CPW phase shift. The measured phase characteristic of the fabricated CPW phase shifter is close to 180$^{\circ}$ over a very broad frequency range of 28 GHz. The measured working frequency of short-end series stub is 28.7 GHz and the return loss is - 20 dB. And the measured working frequency of short-end shunt stub is 28.9 GHz and the return loss is - 23 dB at midband. As a result, the pattering of stub in the center conductor of CPW lines can offer size reduction and lead to high density chip layouts.

Design of Ring Hybrid Balun with Good Amplitude and Phase balance (진폭과 위상 특성이 우수한 링 하이브리드 발룬 설계)

  • Na Won;Cho Il-Hyun;Lee Moon-Que
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.175-178
    • /
    • 2006
  • We present a ring hybrid balun with additional two ${\lambda}/4$ short stubs that offers excellent amplitude and phase balance performance. The phase difference which is essentially occurred in $180^{\circ}$ ring hybrid is compensated by a ${\lambda}/4$ short stub in one output port. To compensate the amplitude imbalance inherent in the ring hybrid, the series resistance will be added to the second stub which is connected to another output port. The measured balun shows that phase imbalance is less than $2.5^{\circ}$ and magnitude imbalance is less than 0.2dB over a 1.75-2.25 GHz.

  • PDF

Analysis of Dual-mode Resonator with Short-Stub (단락형 스터브에 의한 이중 모드 공진기의 해석)

  • Yun, Tae-Soon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.497-499
    • /
    • 2013
  • In this paper, electrical lengths and impedances of a dual-mode resonator are calculated by using the transfer function of a dual-mode resonator by realizing the short-stub. The electrical length of transmission-line for a resonator is function of the frequency and the electrical length of stub is defined by the frequency and impedances of line and stub. Also, the inverter value of a bandpass filter using the dual-mode resonator is calculated. The effect of stub's impedance for inverter is very small. And, as the impedance of line is decreasing, the inverter value is increasing and as the bandwidth is increasing, the inverter value is increasing.

  • PDF

Energy Dissipation Capacity of the T-stub Fastened by SMA bars (SMA 강봉으로 체결된 T-stub의 에너지소산능력)

  • Yang, Jae Guen;Baek, Min Chang;Lee, Jae Yun;Lee, Hyung Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.3
    • /
    • pp.231-240
    • /
    • 2014
  • The T-stub subjected to an axial tensile force shows various behavior characteristics according to the changes in the diameter and tightening force of the fastener, the geometric shape of the T-stub, and the material properties of the T-stub and fastener. Due to the influence of these changes, the T-stub shows three failure modes: plastic failure after the flexural yielding of the T-stub flange, flexural yielding of the T-stub fillet, and fracture of the fastener. In general, a T-stub with a thin flange and where the gauge distance of the fastener is long has a larger energy dissipation capacity than a T-stub with a thick flange and where the gauge distance of the fastener is short, due to the plastic deformation after flexural yielding. In this study, three-dimensional nonlinear finite element analysis was carried out to determine the effect of the fastener used for fastening the T-stub on the energy dissipation capacity of the T-stub. For the fastener of the T-stub analysis model, F10T-M20 high-tension bolts and ${\varnothing}19.05-mm$ (3/4-inch) SMA bars were modeled, and the geometric shape of the T-stub was selected to represent the flexural yielding of the T-stub fillet and the axial tensile failure of the fastener.

Open and Short Stubs Employing the Periodically Arrayed Grounded-strip Structure on the Silicon Substrate and Their Application to Miniaturized RF Filters on the Silicon RFIC

  • Yun, Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.4
    • /
    • pp.217-221
    • /
    • 2016
  • In this work, open and short stubs that were fabricated on the silicon substrate and for which the periodically arrayed grounded-strip structure (PAGS) was employed were studied along with their basic RF characteristics for an applicability regarding the RF-matching components. The PAGS-employing open and short stubs showed losses that are much lower than that of the conventional stub on the silicon substrate. Concretely, the Q values of the open and short stubs are 9 and 10.2, respectively, while the Q value of the conventional open stub is 2.5. With the use of the PAGS-employing open and short stubs, a highly miniaturized harmonic-rejection filter was also fabricated on the silicon substrate. The filter exhibited a comparatively sound harmonic-suppression characteristic at n × 13 GHz, and its size is 0.1 mm2, which is only 7% of the size of the conventional filter on the silicon substrate.

Tests and numerical behavior of circular concrete-filled double skin steel tubular stub columns under eccentric loads

  • Manigandan R.;Manoj Kumar
    • Structural Engineering and Mechanics
    • /
    • v.88 no.3
    • /
    • pp.287-299
    • /
    • 2023
  • This article describes experimental and numerical analyses of eccentrically loaded over the axially loaded circular concrete filled double-skinned steel tubular (CFDST) short columns. Tests on circular CFDST short columns under eccentric and concentric loading were conducted to assess their responses to the frequent intensity of 5-30 mm at the interval of each 5 mm eccentric loading conditions with constant cross-sectional proportions and width-to-thickness ratios of the outside and internal tubes. The non-linear finite-element analysis of circular CFDST short columns of eccentrically loaded over the axially loaded was performed using the ABAQUS to predict the structural behavior and compare the concentric loading capacity over the various eccentric loading conditions. The comparison outcomes show that the axial compressive strength of the circular CDFST short columns was 2.38-32.86%, lesser than the concentrically loaded short column with the inner circular section. Also, the influence of computer simulation employed is more efficient in forecasting the experimentally examined performance of circular CFDST stub columns.