• 제목/요약/키워드: Silencer System

검색결과 34건 처리시간 0.034초

복합형 반사형 소음기의 음향학적 특성과 설계방법 (Design Methodology of Composite Reactive Silencer Based on Acoustic Analysis)

  • 김양한;최재웅;김영
    • 소음진동
    • /
    • 제1권1호
    • /
    • pp.29-38
    • /
    • 1991
  • The performance of silencer system is controlled by the geometrical parameters such as the relative location of inlet and outlet ports, size of main chamber, and cross sectional geometry of inlet-outlet ports and main chamber of silencer. In addition to these parameters, the presence of mean flow and temperature gradient along the silencer also affects the acoustic characteristics of silencer system. Due to the complexity of silencer, it is not straight forward to design the appropriate silencer system. In this paper, a design methodology based on an oustic analysis of silencer system is proposed ; low frequency and high frequency tuning method.

  • PDF

배기 소음기내를 전파하는 비정상 충격파의 수치해석 (Study of the Weak Shock Wave Propagating through an Exhaust Pipe Silencer System)

  • 권용훈;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.462-467
    • /
    • 2001
  • The present study addresses a computational work of the weak shock wave propagatings inside a silencer system of automobile exhaust pipe. Four different types of the silencer systems and the initial shock wave Mach number $M_s$ of $1.01\sim1.30$ are applied to investigate their effects on the noise reduction and the flow field in a silencer system. The results obtained from the present computational work are compared with the experimental results. The second order total variation diminishing (TVD) scheme is employed to solve the two dimensional, compressible, unsteady, Euler equations. The present computational results predict the experimental results with a quite good accuracy. Of the four silencer systems applied, the most desirable silencer system to reduce the peak pressure at the exit of the exhaust pipe is discussed.

  • PDF

흡음형과 공명형 덕트 소음기의 소음저감 성능에 관한 실험적 고찰 (An Experimental Investigation on Noise Reduction Performance of the Absorption and the Resonance Type Duct Silencers)

  • 이영섭;정광섭;이동훈
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.897-901
    • /
    • 2010
  • A silencer has been widely used for the purpose of suppressing the noises propagated from duct of air conditioning system. The absorption type silencer is usually applied to reduce the noise with high frequency bandwidth. On the order hand, the resonance type silencer is applied to reduce the noise with low-middle frequency bandwidth. The insertion loss of silencer is measured in the reverberation room. The cut-off frequency of reverberation room is 100 Hz. The insertion loss of absorption type silencer is more larger than that for resonance type silencer regardless of changing the flow velocity.

155mm 화포의 소음기 설계 및 시험평가에 관한 연구 (A Study on the Design and Testing of 155mm Howitzer Silencer)

  • 여철모;박성호;이해석;김영섭;정한식;정효민
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.144-149
    • /
    • 2014
  • The silencer of 155mm caliber howitzer is developed to reduce its firing loud noise. This kind of research of a large gun was seldom because its big firing noise does not make significant effect even if to use silencer. Nowadays, military facilities became closely located civilian residential area. The noise would be regarded environmental pollution. So the noise reducing research becomes reconsidered. The previous silencer researches were only dealt with small guns as pistols and rifles moreover their theories was not properly analyzed for a large caliber silencer. The reason was previous researches of a large caliber silencer as 155mm howitzer were limited because their data based on simulation results without actual test by using computational fluid dynamics. In this study, the entire processes of silencer of 155mm caliber howitzer which were design, manufacturing, actual firing test, and analysis of its theories, were performed and showed. In particular, the actual noise of with silencer and without was measured and the results were compared to analyze the effect of silencer.

이상소음 해소를 위한 Stack 소음저감 기술개발 (Technology Development of Noise Reduction at Stack for Resolution of Abnormal Noise)

  • 호경찬;이영제;김성진;권혁관;정현일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1049-1052
    • /
    • 2006
  • Object of this study is to develop an Stack Silencer System for quieting abnormal noise around power plant. Abnormal noise gets resident people to feel uncomfortable. Stack Silencer System is to minimize pressure loss of exhaust gas and to maximize noise reduction effect from abnormal noise frequency band. Stack Silencer System is installation in stack and absorbing material is an aluminum foam. Reduction effect measures insertion loss of $8.2{\sim}19.4dB$ by Stack silencer installation. After Stack Silencer System installation, pressure loss of exhaust gas measured $5{\sim}9mmH_2O$.

  • PDF

미세 다공판을 이용한 환기팬 시스템의 소음저감 (Noise Reduction of a Ventilating Fan System using Micro-Perforated Panel)

  • 이종석;송화영;이동훈;권혁정;김동윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1209-1211
    • /
    • 2006
  • This paper introduces an experimental study for the noise reduction of a ventilating fan system. For the purpose of noise reduction, conventionally an absorptive duct silencer filled with a glass fiber has been utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with its noise reduction performance.

  • PDF

환기팬 시스템의 소음특성과 저감에 관한 실험적 연구 (An Experimental Study on the Noise Characteristics and Reduction of a Ventilating Fan System)

  • 김덕한;이동훈;권혁정;김동윤;이종석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.500-505
    • /
    • 2005
  • This paper introduces an experimental study for the noise characteristics and reduction of a ventilating fan system. For the purpose of noise reduction of it, an absorptive duct silencer filled with a glass fiber has been conventionally utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with their sound absorption performances.

  • PDF

보일러용 디퓨저 소음기 설계에 관한 연구 (A Study on Design of Diffuser Sliencer in Boiler)

  • 남경훈;박실룡;이덕주;김재욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 추계학술대회논문집; 한국과학기술회관; 6 Nov. 1997
    • /
    • pp.271-278
    • /
    • 1997
  • The flow of steam through a safety valve vent pipe system in the boiler has been analyzed to provide a design basis of diffuser silencer for attenuating shock-shell and jet noise. Numerical analysis to estimate inner fluid of silencer and noise propagation outside silencer are performed. The distribution curve of fluid information to provide average values about inner fluid of silencer is presented by theoretical analysis.

  • PDF

기하상사법을 이용한 대형 소음기의 성능평가에 관한 해석적 연구 (Analytical Study on Performance Evaluation of Large-Sized Silencer using Geometric Similarity Law)

  • 양준혁;이부윤;김원진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권2호
    • /
    • pp.275-281
    • /
    • 2010
  • 선박용 엔진 또는 플랜트 시스템에 사용되는 대형 소음기의 개발단계에서 비용절감 및 개발기간의 단축을 위하여 축소모형으로 대체 실험이 가능하도록 기하상사법을 제안하고자 한다. 대형 소음기를 구성하고 있는 공명형과 단순 확장관형 소음기의 원형과 축소 모형에 대한 이론식으로부터 기하상사 변수를 규명하였다. 그리고 음향해석을 통하여 조합형과 배플형의 축소 모형에 기하상사법을 적용하여 원형모형의 성능을 예측하고, 이를 원형모형의 실제 성능과 비교하는 방법으로 기하상사 변수를 검증하였다.

덕트 소음기의 실험적 연구 I (ISO 7235) (An Experimental Study on Ducted Silencers I (ISO 7235))

  • 남경훈;박희주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.282-287
    • /
    • 2001
  • The test facility has been manufactured to predict the dynamic insertion loss and the pressure drop for ducted silencers based on ISO 7235. The qualification test of the test facility is necessary for determining the dynamic insertion loss and the pressure drop of the test silencer, and is surveyed the reflection coefficient for an anechoic termination, the velocity profile near the upstream connection to the test silencer, the reduction of the system silencer and the limiting insertion loss due to the flanking sound transmission along the duct walls.

  • PDF