• Title/Summary/Keyword: Silicone sleeve

Search Result 6, Processing Time 0.03 seconds

The Effect of Silicone Sleeve and Taping on Balance and Strength in Anterior Cruciate Ligament Reconstruction Patients

  • Kwon, Hyo-Jeoung;Park, Dae-Sung;Jeong, Ju Ri;Jung, Kwang-Ik
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.3
    • /
    • pp.147-155
    • /
    • 2014
  • Purpose: This study was to determine the effects of before and after application of silicone sleeve on balance and muscle strength in anterior cruciate ligament (ACL) reconstruction patients. Methods: 13 subjects who had one or more months after ACL surgery were involved. Dynamic balance, timed up and go (TUG), stair step, vertical jump, proprioception and isokinetic knee strength were measured while subjects under taped, untapped and silicone sleeve conditions. Results: For 30 seconds one-leg standing, there was a significant improvement under silicone sleeve on operated side with eyes open and both taping and silicone sleeve revealed similar effects with eyes closed (p<0.01). Application of silicone sleeve showed significant effects in proprioceptive function on the operated side compared to both taping and none (p<0.05). For stair step test, TUG and vertical jump was a tendency to improve after application of silicone sleeve, but no significant different. Muscle strength on operated side of quadriceps and hamstring was significantly improved compared with none or taping(p<0.05). Conclusion: Silicone sleeve application for ACL reconstruction patients was effective immediately on improving strength and balance. Therefore, depending on the intended use and the disease is considered appropriate use of silicone sleeve will be able to help prevention and functional movement.

The Analysis of Characteristics of Silicone Rubber in Insulating Oil (절연유에 의한 Silicone Rubber의 특성 변화 분석)

  • Kim, H.J.;Kim, H.J.;Lee, C.M.;Han, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1216-1217
    • /
    • 2008
  • A description is given of impregnated silicone rubber used in accessories for application on outdoor termination (EB-A). We examines the effects of swelling and mechanical/electrical characteristics for impregnated silicone rubber to develop slip on type sleeve of silicone material. There are semi-conductive silicone rubber and insulation silicone rubber. This examination is monitored as a function of the viscosity and temperature of oil during 30hr. We measure elongation at breakdown and AC breakdown strength and volume resistivities of the oil-impregnated silicone rubbers. The measured values are compared to initial value as function of stress relief cone.

  • PDF

The Analysis of HVDC Cable Oil Swelling Characteristics on the Silicone Rubber (HVDC 절연유 중에서 Silicone Rubber의 팽윤특성 분석)

  • Lee, T.H.;Kim, N.Y.;Kim, J.N.;Jeon, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.623-624
    • /
    • 2007
  • This work examines the effects of swelling MI type HVDC cable oil on the semiconductive silicone rubber and silicone rubber as used in accessories for application on outdoor termination (EBA) slip on sleeve. The behavior of volume resistivity is monitored as a function of the amount of cable oil diffused into the material. Resistivities of semiconductive silicone samples up to the typical insulator range (${\sim}10^{10}{\Omega}-cm$) are observed as a consequence of swelling due to the presence of the diffused oil. The measured volume resistivities of the oil-impregnated semiconductive silicone rubber are compared to desired value as function of stress relief cone.

  • PDF

Effect of silicone rubber-sleeve mounted on shear studs on shear stiffness of steel-concrete composite structures

  • Yang, Chang;Yang, Decan;Huang, Caiping;Huang, Zhixiang;Ouyang, Lizhi;Onyebueke, Landon;Li, Lin
    • Steel and Composite Structures
    • /
    • v.44 no.5
    • /
    • pp.741-752
    • /
    • 2022
  • Earlier works have shown that excessive shear stiffness at the steel-concrete interface causes a non-uniform distribution of shear force in composite structures. When the shear studs are wrapped at the fixed end with flexible materials with a low elastic modulus, the shear stiffness at the interface is reduced. The objective of this study was to investigate the effect of silicone rubber-sleeve mounted on shear studs on the shear stiffness of steel-concrete composite structures. Eighteen push-out tests were conducted to investigate the mechanical behavior of silicone rubber-sleeved shear stud groups (SRS-SSG). The dimension and arrangement of silicon rubber-sleeves (SRS) were taken into consideration. Test results showed that the shear strength of SRS-SSG was higher than that of a shear stud group (SSG), without SRS. For SRS-SSG with SRS heights of 50 mm, 100 mm, 150 mm, the shear strengths were improved by 13%, 20% and 9%, respectively, compared to the SSG alone. The shear strengths of SRS-SSG with the SRS thickness of 2 mm and 4 mm were almost the same. The shear stiffness of the SRS-SSG specimens with SRS heights of 50 mm, 100 mm and 150 mm were 77%, 67% and 66% of the SSG specimens, respectively. Test results of specimens SSG-1 and predicted values based on the three design specifications were compared. The nominal single stud shear strength of SSG-1 specimens was closest to that calculated by the Chinese Code for Design of Steel Structures (GB50017-2017). An equation is proposed to consider the effects of SRS for GB50017-2017, and the predicted values based on the proposed equation agree well with the tested results of SRS-SSG.

Development of the Nurse Uniform to Improve Nursing Service - Focused on the Summer Uniform in the General Ward - (간호업무 능률향상을 위한 간호사복 개발 - 일반병동 하복을 중심으로 -)

  • Lee, Mi Kyung;Lee, Jeong Ran
    • Journal of the Korean Society of Costume
    • /
    • v.66 no.6
    • /
    • pp.32-45
    • /
    • 2016
  • The purpose of this study is to propose changes that can be made to improve nurse uniforms in terms of outfit and functionality based on actual wearing conditions and nurse's preference. The proposed nurse uniform was composed of a blouse and pants. The design was as follows: the blouse had short set-in sleeve with China collar, a princess line, and it came down to middle hip. Armhole action pleats and back inverted pleats were embedded for convenient arm movements. The pants waist had a rubber band at the back waist, and the crotch length and the knee width were increased for activity. To make the pocket more accommodative, separate pocket slots treated with silicone were added to prevent belongings from coming out of the pocket. The pink tone of the uniforms, as well as the stripes on the blouses and spandex incorporated pants were based on nurses' preference. the nurse uniforms were produced after measuring the size of women in the age of 25 to 29, and the uniform patterns were corrected after two wearing experiments. Wearing test was examined in terms of appearance and functionality. For appearance, experts gave the uniforms a mean rating of 4.30, and nurses gave a mean rating of 4.00. Functionality was evaluated in terms of ease of activity and storage aspects. The total mean of ease of activity in nursing service was 4.30, whereas the evaluation of storage in terms of pocket position and convenience was 3.80.

The Short Term and Intermediate Term Results of using a T-tube in Patients with Tracheal Stenosis (기관 협착 환자에서의 T-튜브의 중단기 결과)

  • Sa, Young Jo;Moon, Seok-Whan;Kim, Young-Du;Jin, Ung;Park, Jae-Kil;Kim, Jae Jun;Kim, Chi-Kyung;Jo, Keon Hyon;Park, Chan Beom;Yim, Hyeon Woo
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • Background: The treatment of tracheal stenosis includes less invasive bronchoscopic intervention and more invasive segmental resection & anastomosis. Depending on the patient's clinical features, sometimes all these methods are inappropriate. Silicone T-tube stenting has recently been used as an alternative, safe management of tracheal stenosis. We studied the short term and Intermediate term results of using T-tubes in patients with tracheal stenosis, and this tracheal stenosis was caused by various underlying diseases. Material and Method: We retrospectively reviewed 57 patients with tracheal stenosis and who were treated with T-tubes between Jan 1997 and Apr 2007. Based on the patient's medical records and the imaging studies, we evaluated the clinical findings and status of T-tube removal. Result: There was no T-tube related morbidity or mortality in this series. On follow-up, one patient underwent sleeve resection and end-to-end anastomosis. The T-tube could be successfully removed from 13 patients (13/57, 22.8%) without additional interventions. For another four patients, a T-tube was again inserted after removal of the first T-tube due to tracheomalacia or recurrent stenosis. Four patients died of underlying disease and cancer. The patients' gender and previous tracheostomy significantly affected T-tube removal. By contrast, multiple logistic regression analysis identified gender as a predictor of successfully removing a T-tube. Gender (p=0.033) and previous tracheostomy (p=0.036) were the two factors for success or failure of T-tube removal. Conclusion: A T-tube provided reliable patency of a stenotic airway that was caused by any etiology. We have proven that using a T-tube is safe and effective therapy for patients with tracheal stenosis for the short term or the intermediate term.