• Title/Summary/Keyword: Simple Abdomen X-ray

Search Result 15, Processing Time 0.033 seconds

How to Improve Image Quality for the Chest PA and the Simple Abdomen X-ray Examinations (흉, 복부 단순 X-ray 검사 시 영상의 질 향상 방법)

  • Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.165-173
    • /
    • 2013
  • The purpose of this study is to examine how much the movement at X-ray examinations like breathing or the positioning affects the image during chest or abdomen X-ray examination so as to create an image containing information as much as possible. The study method adopted is doing the X-ray in each of the states including breathing (inspiration & expiration) and movement in the standing chest PA X-ray and simple abdomen X-ray among the kinds of examination selected the most in hospitals and then evaluating them by applying the standards of image evaluation for each region. According to the study result, about the standing chest PA X-ray, the images taken at inspiration contain more information than those taken at expiration or having subtle movement during the examination. About the simple abdomen X-ray, the images taken at expiration contain more information than those taken at inspiration or movement. The above study results imply that regarding general X-ray examination, information we can find from the images may differ significantly according to the region examined, examination purpose, or movement during the examination like breathing.

A Survey on Patient Dose and Exposure Conditions in Simple Radiography of the Abdomen (복부 단순 X-선 촬영조건과 환자 피폭에 관한 조사 연구)

  • Kim, Sung-Soo;Lee, Sun-Sook;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.59-65
    • /
    • 1996
  • We studied exposure techniques and exposure dose for simple abdomen A-P projection for 41 medical facilities that are located in Seoul area. 1. The range of tube voltage used was 60 to 84 kVp, the average tube voltage used was 74 kVp 2. Only 17% of added filter was used. 3. Tube current mostly used was 200 mA, some of them used 400 mA. 4. The grid ratio mostly was used 10 : 1, 54 % of the rare earth screen was used in most facilities. 5. The average skin entrance dose was 4.15 mSv and the dose range was 1.05 mSv to 11.0 mSv.

  • PDF

A study on the Radiation exposure of simple abdomen x-ray in Radiography (복부 단순 X선검사시 피복 선량에 관한 연구)

  • Ko In Ho;Lee Kyung Sung;Shin Dong Yong
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.57-65
    • /
    • 2001
  • This study was performed to measure about exposure dose during simple abdomen x-ray Radiography. The exposure dose was measured by PDD, surface dose, percentage scatter dose, respectively. The result was as followed: 1. When tube voltage were increased wi

  • PDF

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

A Study of the Medical Exposure Dose in Abdomen A-P X-ray Examination (복부(腹部) 단순X선검사시(單純X線檢査時) 피검자(被檢者)의 피폭선량(被曝線量)에 대(對)한 연구(硏究))

  • Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.17 no.1
    • /
    • pp.49-54
    • /
    • 1994
  • This study was conducted to find out the medical exposure dose in simple abdomen A-P projection of adults, based on the 87 hospitals located in Seoul. As the results, the following conclusions have been reached; 1. 88.5 % of the surveyed hospitals had the use of $65\;kVp{\sim}79\;kVp(M{\pm}SD:71.45{\pm}4.73\;kVp)$ as tube voltage. 2. 87.35 % of the surveyed hospitals had the use of $50\;mAs{\sim}89\;mAs(M{\pm}SD:64.31{\pm}16.21\;mAs)$ as the amount of current. 3. Shallow doses ranged from 2.00 mSv to 4.99 mSv($M{\pm}SD:3.81{\pm}1.01\;mSv$) in 80.46 % of the surveyed hospitals. 4. Exposure dose was directly depended on the tube voltage or the amount of currents.

  • PDF

Utility of Spinal Injury Diagnosis Using C-Spine Lateral X-Ray and Chest, Abdomen and Pelvis Computed Tomography in Major Trauma Patients with Impaired Consciousness

  • Jang, Yoon Soo;So, Byung Hak;Jeong, Won Jung;Cha, Kyung Man;Kim, Hyung Min
    • Journal of Trauma and Injury
    • /
    • v.31 no.3
    • /
    • pp.151-158
    • /
    • 2018
  • Purpose: The regional emergency medical centers manage the patients with major blunt trauma according to the process appropriate to each hospital rather than standardized protocol of the major trauma centers. The primary purpose of this study is to evaluate the effectiveness and influence on prognosis of additional cervical-thoracic-lumbar-spine computed tomography (CTL-spine CT) scan in diagnosis of spinal injury from the victim of major blunt trauma with impaired consciousness. Methods: The study included patients visited the urban emergency medical center with major blunt trauma who were over 18 years of age from January 2013 to December 2016. Data were collected from retrospective review of medical records. Sensitivity, specificity, positive predictive value, and negative predictive value were measured for evaluation of the performance of diagnostic methods. Results: One hundred patients with Glasgow coma scale ${\leq}13$ underwent additional CTL-spine CT scan. Mechanism of injury was in the following order: driver, pedestrian traffic accident, fall and passenger accident. Thirty-one patients were diagnosed of spinal injury, six of them underwent surgical management. The sensitivity of chest, abdomen and pelvis CT (CAP CT) was 72%, specificity 97%, false positive rate 3%, false negative rate 28% and diagnostic accuracy 87%. Eleven patients were not diagnosed of spinal injury with CAP CT and C-spine lateral view, but all of them were diagnosed of stable fractures. Conclusions: C-spine CT scan be actively considered in the initial examination process. When CAP CT scan is performed in major blunt trauma patients with impaired consciousness, CTL-spine CT scan or simple spinal radiography has no significant effect on the prognosis of the patient and can be performed if necessary.

A case of ARDS Overlooked Tsutstugamushi Disease that Presented as Simple Cutaneous Lesions (단순 피부병변으로 간과되어 급성 호흡곤란 증후군으로 진행된 쯔쯔가무시병 1예)

  • Ryu, Ki Hyun;Kim, Ki Hong;Kim, Hong Dai;Son, Ji Woong;Na, Moon Jun;Choi, Eugene
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.4
    • /
    • pp.389-393
    • /
    • 2006
  • Tsutstugamushi disease is a major febrile disease that generally occurs in the fall in Korea with hemorrhagic fever with renal syndrome and leptospirosis. This disease is often accompanied by interstitial pneumonia, acute renal failure and liver failure. The causative agent, namely Orientia tsutsugamushi, is transmitted to humans through the bite of a laval trombiculid mite, which is commonly known as a chigger. A 78 year old man was admitted in October 2004 with intractable fever and a drowsy mentality. Two weeks earlier, he visited a private clinic complaining of a simple skin rash. He was treated with antihistamine and steroid, but his symptoms were aggravated and he was referred to our hospital. His physical examination and laboratory findings showed a septic shock status. The maculopapular rash had spread over his face, chest, abdomen and extremities. Eschar was observed in lower back area but it was too difficult to distinguish it from other skin rashes. His chest X-ray appeared as diffuse nodular patchy consolidations in the bilateral lung parenchyme. He was treated with a mechanical ventilator and doxycycline under th suspicion of Tsutstugamushi disease. However, he suffered multiorgan failure accompanied by acute respiratory distress syndrome, acute renal failure and acute hepatitis. He was treated in the intensive care unit for approximately 12 weeks and his general condition was recovered.

The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen (복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Je-Bong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • 1. Purpose : This study is to present effective exposure conditions to acquire the best image of simple abdomen in Film Screen (F.S) system and Computed Radiography (C.R) system. 2. Method : In the F.S system, while an exposure condition was fixed as 70kVp, images of a patients simple abdomen were taken under the different mAs exposure conditions. Among these images, the best one was chosen by radiologists and radiological technologists. In the C.R system, the best image of the same patient was acquired with the same method from the F.S system. Both characteristic curves from F.S system and C.R system were analyzed. 3. Results : In the F.S system, the best exposure condition of simple abdomen was 70kVp and 20mAs. In the CR system, with the fixed condition at 70kVp, the image densities of human organs, such as liver, kidney, spleen, psoas muscle, lumbar spine body and iliac crest, were almost same despite different environments (3.2mAs, 8mAs, 12mAs, 16mAs and 20mAs). However, when the exposure conditions were over or under (below) 12mAs, the images between the abdominal wall and the directly exposed part became blurred because the gap of density was decreased. In the C.R system, while the volume of mAs was decreased, an artifact of quantum mottle was increased. 4. Conclusion : This study shows that the exposure condition in the C.R system can be reduced 40% than in the F.S system. This paper concluded that when the exposure conditions are set in CR environment, after the analysis of equipment character, such as image processing system(EDR : Exposure Data Recognition processing), PACS and so on, the high quality of image with maximum information can be acquired with a minimum exposure dose.

  • PDF

A Case of Pathologic Aerophagia with Mental Retardation Managed by Percutaneous Endoscopic Gastrostomy (경피적 내시경적 위루술을 이용한 병적 공기 연하증 치료 경험 1례)

  • Lee, Eun-Joo;Song, Ae-Ryong;Choi, Eun-Jin;Hwang, Jin-Bok;Oh, Hee-Jong;Lee, Young-Hwan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.3 no.1
    • /
    • pp.93-97
    • /
    • 2000
  • We experienced a case of pathologic aerophagia in a 10-year-old girl who has mental retardation. It was observed that the abdomen was non-distended in the morning and became maximally distended in the evening. Increased passage of flatus, but normal eructation, was noted. Roentgenographic examination showed 'esophageal air sign', abnormal air shadow on proximal esophagus adjacent to the trachea, in simple chest X-ray and visible air swallowing fluoroscopically. We tried a percutaneous endoscopic gastrostomy (PEG) to decompress swallowed air in stomach. We suggest that placement of a PEG catheter in early life, especially in mentally retarded patients, that can be used as desufflator, can prevent the complications of aerophagia. 'Esophageal air sign' may be very helpful for early detection of pathologic aerophagia.

  • PDF

The Spread of Contrast Media in Celiac Plexus Block (복강신경총 차단시의 조영제 확산)

  • Lee, Jung-Koo;Chung, Jung-Kil;Lee, Sung-Moon
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.211-216
    • /
    • 1994
  • Celiac plexus block is performed to relieve intractable upper abdominal cancer pain. Generally, celiac plexus blocks have been performed under control of X-ray fluoroscopy to determine the position of the needle tip and the spread of contrast media. During the period from March 1992 to February 1994, we have performed 21 cases of neurolytic celiac plexus block to alleviate pain of intra-abdominal malignancy. We retrospectively evaluated the location of the needle tip and the spread of contrast media. P-A views of simple abdomen demonstrated the locations of the needle tip: 66.7% of the left needle tips were in upper 3/1 of L1 (6 cases) and $T_{12}-L_1$ interspace (8 cases), 50% of the right needle tips were in upper 1/3 of $L_1$, (6 cases) and $T_{12}-L_1$ interspace (4 cases). Contrast media from the right needle spread upward to middle 1/3 of $T_{10}$ (5 cases) and middle 1/3 of $T_{11}$ (5 cases), downward to middle 1/3 of $L_1$ (6 cases) and lower 1/3 of $L_1$ (3 cases). Contrast media from the left needle were spread upward to middle 1/3 of $T_{10}$ (5 cases) and evenly to other spaces, downward to middle 1/3 of $L_1$, (4 cases) and $L_1-L_2$ interspace (6 cases). We analyze the spread of contrast media according to distance from needle tip by authors score system. Contrast media of right needle spread upward 6.1 and downward 3.4, that of left needle spread upward 6.5 and downward 3.7.

  • PDF