• Title/Summary/Keyword: Simple Structure

Search Result 4,524, Processing Time 0.045 seconds

A Simple Design Method of Un-reinforced Masonry Wall (비보강 조적 벽체의 간이 설계법(設計法))

  • Yoon, Myung-Ho;Cho, Byoung-Hoo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.2 no.1
    • /
    • pp.45-51
    • /
    • 2002
  • The masonry structure has been widely used as the dwelling house structure in our country for a long time. The masonry structure is weak in the lateral forces such as strong wind and earthquake. But there is no regulation for it in the domestic aseismic design codes. The purpose of this study is to suggest a simple design method of un-reinforced masonry wall.

  • PDF

Fabrication of simple bi-layered structure red and green PHOLEDs

  • Jeon, Woo-Sik;Park, Tae-Jin;Kwon, Jang-Hyuk;Pode, Ramchandra;Ahn, Jeung-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.34-36
    • /
    • 2008
  • Highly efficient red and green phosphorescent devices comprising a simple bilayer structure are reported. The driving voltage to reach $1000\;cd/m^2$ is 4.5 V in $Bebq_2:\;Ir(piq)_3$ red phosphorescent device. Current and power efficiency values of 9.66 cd/A and 6.90 lm/W in this bi-layered simple structure PHOLEDs are obtained, respectively. While in $Bepp_2:Ir(ppy)_3$ green phosphorescent device, the operating voltage value of 3.3V and current and power efficiencies of 37.89 cd/A and 35.02 lm/W to obtain a luminance of $1000\;cd/m^2$ are noticed, respectively.

  • PDF

A Simple Learning Variable Structure Control Law for Rigid Robot Manipulators

  • Choi, Han-Ho;Kuc, Tae-Yong;Lee, Dong-Hun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.354-359
    • /
    • 2003
  • In this paper, we consider the problem of designing a simple learning variable structure system for repeatable tracking control of robot manipulators. We combine a variable structure control law as the robust part for stabilization and a feedforward learning law as the intelligent part for nonlinearity compensation. We show that the tracking error asymptotically converges to zero. Finally, we give computer simulation results in order to show the effectiveness of our method.

  • PDF

Some Results on Simple-Direct-Injective Modules

  • Derya Keskin Tutuncu;Rachid Tribak
    • Kyungpook Mathematical Journal
    • /
    • v.63 no.4
    • /
    • pp.521-537
    • /
    • 2023
  • A module M is called a simple-direct-injective module if, whenever A and B are simple submodules of M with A ≅ B and B is a direct summand of M, then A is a direct summand of M. Some new characterizations of these modules are proved. The structure of simple-direct-injective modules over a commutative Dedekind domain is fully determined. Also, some relevant counterexamples are indicated to show that a left simple-direct-injective ring need not be right simple-direct-injective.

Analysis for the Composition Element in Structure of Chairs - Focusing on Milan International Furniture Fair - (의자디자인 구조의 결합 유형에 관한 연구 - 밀라노 국제 가구 박람회를 중심으로 -)

  • Oh, Se-Hwan;Park, Young-Soon
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.36-43
    • /
    • 2009
  • Structure is one of the most important components in designing chairs, since a chair should support the weight of users and make them feel comfortable. However, previous studies have focused on examining the materials and the techniques of processing of chairs, but less on studying the structures to facilitate human friendly use enough to influence the change of the current chair design. The purpose of this study is to analyze the composition element in structure of the chair design specifically from 2000 to 2008 the fundamentals to achieve quality chair design. This study examined 386 chairs which the most reputable furniture fair, the Milan International Furniture Fair exhibited from 2000 to 2008. 386 chairs were chosen from 72 companies which passed the popularity and ranks. 24 Components of the structure of chairs were used to annalize the 386 chairs. The structural types of chair design included 51 kinds. Among them, the most representative types appeared to be 5 kinds. Particularly, the single structure chair was comprised of 25%, its productivity has increased steadily since 2004 which indicated that the structure of chair has become simplified. According to the components of chair, classified structure types were analyzed into (1) a single structure consisting of one component, (2) a simple structure with two components, (3) a complex structure with three components, and (4) a multiple structure with four components. The majority of chair types followed the order of the single structure, simple structure, complex structure, and multiple structure. The results of the analysis on the structure of chairs indicated that the structure of chairs has been changed toward single type No. 24 and simple type No. 6+13.

Stochastic response spectra for an actively-controlled structure

  • Mochio, Takashi
    • Structural Engineering and Mechanics
    • /
    • v.32 no.1
    • /
    • pp.179-191
    • /
    • 2009
  • A stochastic response spectrum method is proposed for simple evaluation of the structural response of an actively controlled aseismic structure. The response spectrum is constructed assuming a linear structure with an active mass damper (AMD) system, and an earthquake wave model given by the product of a non-stationary envelope function and a stationary Gaussian random process with Kanai-Tajimi power spectral density. The control design is executed using a linear quadratic Gaussian control strategy for an enlarged state space system, and the response amplification factor is given by the combination of the obtained statistical response values and extreme value theory. The response spectrum thus produced can be used for simple dynamical analyses. The response factors obtained by this method for a multi-degree-of-freedom structure are shown to be comparable with those determined by numerical simulations, demonstrating the validity and utility of the proposed technique as a simple design tool. This method is expected to be useful for engineers in the initial design stage for structures with active aseismic control.

Comparison of Confidence Intervals on Variance Component In a Simple Linear Regression Model with Unbalanced Nested Error Structure

  • Park, Dong Joon;Park, Sun-Young;Han, Man-Ho
    • Communications for Statistical Applications and Methods
    • /
    • v.9 no.2
    • /
    • pp.459-471
    • /
    • 2002
  • In applications using a linear regression model with nested error structure, one might be interested in making inferences concerning variance components. This article proposes approximate confidence intervals on the variance component of the primary level in a simple linear regression model with an unbalanced nested error structure. The intervals are compared using computer simulation and recommendations are provided for selecting an appropriate interval.

A New Comb Circular Polarizer Suitable for Millimeter-Band Application

  • Eom, Soon-Young;Korchemkin, Y.B.
    • ETRI Journal
    • /
    • v.28 no.5
    • /
    • pp.656-659
    • /
    • 2006
  • This letter presents a new polarizer which has a simple comb structure inside a circular waveguide. The electrical performance of the proposed comb polarizer is optimized by a circular waveguide radius and by the physical parameters of the comb plates. This polarizer is suitable for providing good performance in millimeter-band application because of its simple structure and low fabrication cost. In our experiments the dual-band comb polarizer designed in band 1(K) and band 2(Ka) showed good electrical performance without any tuning elements.

  • PDF

ZVS Half-bridge Converter of Simple Structure (간단한 구조의 영전압스위칭 하프브리지 컨버터)

  • Yoo, Doo-Hee;Jeong, Gang-Youl;Lee, Jae-Min
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.444-446
    • /
    • 2007
  • This paper presents a ZVS (Zero Voltage Switching) half-bridge converter of simple structure. The operational principle of the proposed converter is explained, briefly. It is shown through that the experimental results the proposed converter operates excellently as a high efficiency converter. As the proposed converter utilizes the transformer leakage inductor as the resonant inductor, its structure is simplified.

  • PDF

A Study on Plan Structure Types and Characteristics of Wall Formation in Art Museum Exhibition Spaces

  • Lee, Jong-Sook
    • Architectural research
    • /
    • v.13 no.3
    • /
    • pp.3-10
    • /
    • 2011
  • The Characteristics of space are determined by several factors; however, the element that determines the physical characteristic of floors, walls, and ceiling is the structure. This study constructs a wall to analyze the direct effect that the layout of an exhibition wall has on the element of the wall followed by the structural process and visibility of descriptive analysis and examples of art museums that the shift from a perceptional wall to an experiential wall affected circulation. For elements and formation methods of the wall, first, it is made up of open and closed type exhibition spaces, and it can give abundance in qualitative space rather than a quantitative aspect. Secondly, the directivity of space changes according to the development of the visible axis, thus, directly affects the change in visibility. Thirdly, the difference between spatial structure and visual structure is the difference between the visual axis and spatial structure. The wall formation type followed by the combination method, the simple visible structure, which is the type that possesses the simple combination (Room, Zone, Cluster), repeatedly uses the same size of units of space that is orderly and has few spatial axes and the classification of simple type and simple cluster type, which has few visible axes, also exists. Also, with the complex structure of the maze type it displays the reiterated form of the cluster, which is the space with disorderly combination and has much visible axes and spatial axes. Also, these can be divided into three types: 1) Maze Cluster Type, 2) Cross Road Type, and 3) Open Flexible Type. These wall types lead the various changes in circulation, and even each of the arrangement qualities of the exhibitions should be researched according to its exhibition place type.