• 제목/요약/키워드: Slab joint

검색결과 222건 처리시간 0.029초

PT 플랫 플레이트와 RC 플랫 플레이트 내부 접합부의 구조적 거동 비교에 관한 실험적 연구 (An Experimental Study on Comparison of Structural Behavior of PT Flat Plate and RC Flat Plate Interior Connections)

  • 이동근;하상수;한상환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.111-114
    • /
    • 2005
  • While the existing reinforced concrete flat plate(RC flat plate) has a lot of advantages including reduced building height, it has some weak points such as many steel bars and the brittle rupture by punching shear. Compared with the RC flat plate, the post-tensioned flat plate (PT flat plate) has not only the same merits, but it also makes longer span possible and induces slab-column connections to be failed with the ductile behavior rather than with the brittle behavior by means of post-tensioning. However, it is difficult to define the joint behavior of PT flat plate under vertical and lateral loads since there are limit experimental results. For this reason, the experimental study is undertaken to investigate the comparison of behavior of PT flat plate and RC flat plate, and how flat plate(Gravity Load Resisting System) is displaced as lateral loads, like the wind and the earthquake, are occur. The result of this experiment shows that PT flat plate is generally superior to RC flat plate in terms of controlling crack, postponing stiffness deterioration, energy dissipation, etc.

  • PDF

콘크리트 포장에서 FRP 튜브 다웰바의 역학적 특성 분석 (Structural Analysis of Concrete-filled FRP Tube Dowel Bar for Jointed Concrete Pavements)

  • 박준영;이재훈;손덕수
    • 한국도로학회논문집
    • /
    • 제13권3호
    • /
    • pp.21-30
    • /
    • 2011
  • 콘크리트 포장의 다웰바는 교통하중을 줄눈 넘어 인접한 슬래브로 전달하는 하중전달장치이다. 현재 국내에서 사용되는 다웰바는 원형봉강으로 교통하중과 환경하중으로 인해 반복적으로 발생하는 전단응력과 휨응력에 대해 높은 내구성을 갖고 있다. 그러나, 강재 다웰바는 장기간 공용시 줄눈틈, 포장 하부 등으로 침투한 수분으로 인해 부식이 발생한다. 특히, 겨울철에 사용되는 제설용 염수와 접촉할 경우 부식은 급격히 진행된다. 다웰바에 부식이 발생하면 부피가 증가하여 줄눈의 거동을 방해하며 유효단면적의 감소로 하중전달효과가 떨어질 수 있다. 이와 함께 지속적인 원자재 가격의 상승으로 강재 다웰바의 가격 경쟁력이 크게 낮아지고 있다. 이러한 강재 다웰바의 문제점은 새로운 재료를 사용한 대체 다웰바의 개발로 이어지고 있다. 본 연구에서는 높은 인장강도, 높은 내부식성을 갖춘 FRP(fiber reinforced plastic)를 튜브 형태로 제작하고 그 속을 고강도 무수축 모르타르로 충진한 FRP 튜브 다웰바에 대한 역학적 두께 설계를 실시하였다. 역학적 두께 설계의 기준으로 다웰바와 콘크리트 면 사이에 발생하는 지압응력을 사용하였다. 지압응력의 산정을 위하여 다웰바에 전달되는 교통하중을 이론식과 유한요소해석을 통해 산출하고 실내시험을 통해 FRP 튜브 다웰바의 물성을 측정하였다. 그 결과, 직경 32mm, 40mm FRP 튜브 다웰바 모두 지압응력 기준을 만족하는 것으로 나타났다. 국내 콘크리트 포장은 콘크리트 슬래브 하부에 강성이 큰 린 콘크리트층을 사용하기 때문에 다웰바에 전달되는 교통하중이 적고 이로 인해 지압응력도 낮아져 상대적으로 적은 직경의 FRP 튜브 다웰바의 사용이 가능한 것으로 판단된다.

굽힌 후 편 철근의 겹침 이음 및 기계적 이음을 갖는 벽-슬래브 접합부의 반복하중에 대한 거동 (Cyclic Behavior of Wall-Slab Joints with Lap Splices of Coldly Straightened Re-bars and with Mechanical Splices)

  • 천성철;이진곤;하태훈
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.275-283
    • /
    • 2012
  • 초고층 건축물의 선행 코어 후행 슬래브 접합부, 지하 연속벽과 바닥구조의 접합부, 임시 개구부 등 신구 콘크리트 접합부의 철근 이음을 위하여, 다수의 커플러를 전단키가 있는 얇은 강판에 설치한 철근 이음용 매립 강판이 최근 개발되었다. 이 공법을 사용한 접합부의 구조 성능을 검증하기 위하여, 벽체-슬래브 접합부에 대한 반복하중 실험을 실시하였다. 비교를 위해 기존에 사용되는 굽힌 철근 박스를 이용한 접합부와 이음이 없는 접합부도 함께 실험하였다. 실험 결과 철근 이음용 매립 강판을 사용한 접합부는 이음이 없는 접합부와 동일하게 [인장철근 항복]-[충분한 휨변형]-[압축 콘크리트 압괴] 후 압축 철근의 좌굴로 파괴되었다. 따라서 설계에서 가정한 충분한 연성 거동을 확인할 수 있었다. 반면, 굽힌 철근 박스를 사용한 접합부의 경우, 탄성구간에서는 철근 이음용 매립 강판과 유사하게 거동하였으나, 측면 피복 콘크리트가 빨리 탈락되었으며, 슬래브 상하부면의 겹침이음 구간에 부착 균열이 다수 발생하였다. 최종적으로 이음 없는 실험체 및 철근 이음용 매립 강판을 사용한 실험체에 비해 강도와 변형능력이 저하되었다. 또한 굽힌 후편 철근을 겹침이음한 실험체가 철근 이음용 매립 강판을 적용한 경우에 비해 강성 저하가 빠르게 진행되었다. 굽힌 후편 철근의 탄성계수는 직선 철근에 비해 낮고, 완전한 직선으로 펼 수 없기 때문에 인장력을 받으면서 일부 구간이 펴지므로 접합부의 강성을 저하시킨 것으로 판단된다. 2종류의 철근 지름(D13, D16)과 강종(SD300, SD400)에 대해, 철근이음용 매립 강판을 적용한 접합부는 공칭 강도를 충분히 상회하였다. 그러나 굽힌 후 편 철근을 사용하면 강종이 높을수록 그리고 지름이 굵을수록 휨강도가 저하되었다. 따라서 굽힌 후 편 철근의 사용에 주의가 필요하다.

연속철근 콘크리트 포장 단부 및 수평균열 거동 실험적 분석 (Experimental Analysis of Terminus and Horizontal Crack Behaviors in Continuously Reinforced Concrete Pavement)

  • 조영교;김성민;안주옥;한승환
    • 한국도로학회논문집
    • /
    • 제13권4호
    • /
    • pp.81-91
    • /
    • 2011
  • 본 연구는 연속철근 콘크리트 포장(CRCP: Continuously reinforced concrete pavement)에서 단부 앵커러그 유무에 따른 종방향 변위 비교를 통해 앵커러그의 필요성을 분석하고 내부 수평균열의 수직방향 변위 측정을 통해 이러한 균열이 CRCP의 공용성에 미치는 영향을 분석하기 위하여 수행되었다. 앵커러그 구간 절단 전 거동 측정은 6월 중에 12일간 계측하였으며, 앵커 러그 구간 절단 후의 측정은 절단 시 슬래브에 급격히 발생하는 변위가 사라진 이후 8월 중에 14일 동안 계측하였다. 이와 같은 단기간의 계측 결과 CRCP 단부의 종방향 변위는 앵커러그가 설치되어 있는 경우에는 모든 위치에서 일일 변위 변화가 0.1mm 이내로 종방향 거동이 거의 발생하지 않았다. 단부에 앵커러그가 설치되지 않은 경우에는 변위가 자유 단부 부근에서만 주로 발생하며 종방향 변위 변화가 작아서 팽창줄눈으로 처리하여도 적절할 것으로 예측되었으나, 향후 추가연구에 의해 사계절 온도변화에 따른 단부의 거동을 확인할 필요가 있을 것으로 판단된다. 내부 수평균열은 거동 측정 결과 거의 비활성균열이며 전체적인 슬래브의 수직변위에 영향을 미치지 않았다. 따라서 수평균열이 슬래브를 상하로 분리시켜 CRCP의 구조적인 성능 및 공용성의 저하를 유발하지는 않을 것으로 분석되었다.

두꺼운 콘크리트포장의 원위치파쇄 기층화공법 (Rubblization of Thick Concrete Pavement)

  • 이승우;한승환;고석범;김지원
    • 한국도로학회논문집
    • /
    • 제8권3호
    • /
    • pp.105-114
    • /
    • 2006
  • 노후 콘크리트포장 수명을 연장하기 위한 방안으로 아스팔트 덧씌우기가 일반적이나 반사균열을 억제하기 어렵다는 단점이 있다. 이러한 반사균열을 억제하기 위하여 줄눈부 보수, 응력완화층 설치가 적용되기는 하지만 반사균열의 진전 속도를 늦추는 제한적인 성공을 보여 왔다. 콘크리트포장 슬래브를 원위치에서 파쇄하여 기층재료로 활용하고 그 위에 덧씌우기 포장을 건설하는 원위치파쇄기층화 공법은 기존 덧씌우기 보강공법이 갖고 있는 반사균열 문제를 완벽하게 해결할 수 있는 장점을 가지고 있다. 본 공법을 적용할 경우 파쇄된 노후 콘크리트 포장의 상부층은 40mm-70mm로 파쇄되나 하부층은 100mm 이상 되는 경우가 일반적이다. 그러나 콘크리트 두께가 30cm 이상 되는 경우에는 전체두께를 적정 Size로 파쇄골재화하는 것이 어렵다. 따라서 파쇄된 노후 콘크리트 포장층이 반사균열을 유발시키지 않고 도로기층으로서의 역할을 확보할 수 있는 적정 파쇄 깊이를 파악하기 위하여 파쇄골재깊이를 0cm, 10cm, 20cm로 변화시켜가며 simulation test를 수행한 결과, 적정 파쇄 깊이 10cm를 도출하였다(Lee, 2006). 또한 소형파쇄장비를 제작하여 실제 도로와 동일한 기준으로 시험 포장을 건설하여 파쇄헤드 형상, 파쇄에너지, 유효파쇄 면적 등을 달리하여 두꺼운 콘크리트포장형식에 적합한 파쇄방법을 개발하였으며 Prototype의 파쇄장비를 개발하여 실제 공용중인 고속도로에서 시험시공 및 모니터링을 실시하여 제안된 파쇄방법의 적정성을 검토하였다.

  • PDF

Influence of exterior joint effect on the inter-story pounding interaction of structures

  • Favvata, Maria J.;Karayannis, Chris G.;Liolios, Asterios A.
    • Structural Engineering and Mechanics
    • /
    • 제33권2호
    • /
    • pp.113-136
    • /
    • 2009
  • The seismic induced interaction between multistory structures with unequal story heights (inter-story pounding) is studied taking into account the local response of the exterior beam-column joints. Although several parameters that influence the structural pounding have been studied sofar, the role of the joints local inelastic behaviour has not been yet investigated in the literature as key parameter for the pounding problem. Moreover, the influence of the infill panels as an additional parameter for the local damage effect of the joints on the inter-story pounding phenomenon is examined. Thirty six interaction cases between a multistory frame structure and an adjacent shorter and stiffer structure are studied for two different seismic excitations. The results are focused: (a) on the local response of the critical external column of the multistory structure that suffers the hit from the slab of the adjacent shorter structure, and (b) on the local response of the exterior beam-column joints of the multistory structure. Results of this investigation demonstrate that the possible local inelastic response of the exterior joints may be in some cases beneficial for the seismic behaviour of the critical column that suffers the impact. However, in all the examined cases the developing demands for deformation of the exterior joints are substantially increased and severe damages can be observed due to the pounding effect. The presence of the masonry infill panels has also been proved as an important parameter for the response of the exterior beam-column joints and thus for the safety of the building. Nevertheless, in all the examined inter-story pounding cases the presence of the infills was not enough for the total amelioration of the excessive demands for shear and ductility of the column that suffers the impact.

An experimental study of the behaviour of double sided welded plate connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.1-22
    • /
    • 2018
  • Multi-storey precast concrete skeletal structures are assembled from individual prefabricated components which are erected on-site using various types of connections. In the current design of these structures, beam-to-column connections are assumed to be pin jointed. Welded plate beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is at present limited information concerning their detailed structural behaviour under bending and shear loadings. The experimental work has involved the determination of moment-rotation relationships for semi-rigid precast concrete connections in full scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and weld arrangements conformed with successful commercial practice. Proprietary hollow core slabs were tied to the beams by tensile reinforcing bars, which also provide the in-plane continuity across the connections. The strength of the connections in the double sided tests was at least 0.84 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.7 to 3.9 times the flexural stiffness of the attached beam. When the connections were tested without the floor slabs and tie steel, the reduced strength and stiffness were approximately a third and half respectively. This remarkable contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. In general, the double sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided welded plate connection test results are presented in this paper. The behaviour of single sided welded plate connection test results is the subject of another paper.

노후콘크리트포장 원위치 파쇄기층(Rubblized-PCC)의 반사균열 억제를 위한 적정 파쇄 깊이 산정 (Estimation for optimum crush depth to prevent reflection crack for Rubblized-PCC in PCC pavements)

  • 이승우;전상민
    • 한국도로학회논문집
    • /
    • 제6권4호
    • /
    • pp.101-108
    • /
    • 2004
  • 노후콘크리트 포장 수명을 연장하기 위한 방안으로 아스팔트 덧씌우기가 일반적이나 반사균열을 억제하기 어렵다는 단점이 있다. 반사균열을 억제하기 위하여 줄눈부 보수, 응력 완화층 설치가 적용되는 경우가 있으나 반사균열의 진전 속도를 늦추는 제한적인 성공을 보여 왔다. 콘크리트포장 슬래브를 원위치에서 파쇄하여 기층재료로 활용하고 그 위에 덧씌우기 포장을 건설하는 러블라이제이션 공법은 기존 덧씌우기 보강 공법을 갖고 있는 반사균열 문제를 완벽하게 해결할 수 있는 장점을 가지고 있다. 러벌라이제이션 공법을 적용할 경우 파쇄된 노후 콘크리트 포장층 상부층은 40mm-70mm로 파쇄되나 하부층은 100mm이상 되는 경우가 일반적이다. 국내 고속도로와 같이 상대적으로 두꺼운 콘크리트 포장 슬래브를 사용하는 경우 전체 포장 두께를 파쇄하기에 어려움이 있다. 따라서 파쇄된 노후 콘크리트 포장층이 반사균열을 유발시키지 않는 도로기층으로써의 역활을 확보하기 위한 적정 파쇄 깊이를 파악하기 위하여 본 연구에서는 미국 DOT에서 제안한 일반적인 파쇄규격(40mm-70mm)을 기준으로 파쇄 깊이를 0cm, 10cm, 20cm,로 변화시켜가며 반사균열 실내 모사 실험을 수행하여 반사균열 저항 특성을 분석하고 적정파쇄 깊이를 검토하였다.

  • PDF

얇은 콘크리트 덧씌우기 포장의 거동 평가 (Behavior Analysis of Ultra-Thin Whitetopping in Field)

  • 강장환;장진연;구한모;조윤호
    • 한국도로학회논문집
    • /
    • 제6권1호
    • /
    • pp.25-36
    • /
    • 2004
  • 국내 고속국도 및 일반국도의 약40%, 98%가 아스팔트 포장으로 구성되어 있으며 아스팔트 포장의 주요 파손 형태는 러팅(rutting) 및 균열이다. 파손이 심한 아스팔트 포장에 공용성이 좋은 것으로 알려져 있는 UTW(Ultra-Thin Whitetopping, 이하 중 신 콘)가 국내 도로의 유지보수 공법으로 적용될 수 있는가를 판단하였다. 본 논문은 경기도 폐도에 시험 시공된 중 신 콘 포장에서의 정적하중재하실험을 통하여 교통하중 및 환경하중 조건에 따른 중 신 콘의 거동 분석 결과이다. 콘크리트 두께를 50, 100, 150mm로 하여 두께에 따른 거동을 분석한 결과, 콘크리트 두께가 50mm일 때 콘크리트 하부에서 발생하는 인장 변형률이 급격하게 증가한다는 것을 알 수 있었다. 또한 계절별 실험을 통해 포장 온도가 중 신 콘 거동에 미치는 영향이 큰 것을 알 수 있었다. 하중재하위치에 따른 거동분석 결과에서는 슬래브 중앙부와 줄눈부에서 약 25cm 떨어진 지점부터 하중이 재하될 때 중앙부와 줄눈부에 영향을 미치기 시작하였고 이 때, 최대 인장 변형률의 75%까지 변형률이 발생함에 따라 줄눈간격 결정에 주의를 요해야 할 것으로 판단되었다.

  • PDF

80 MPa급 콘크리트를 활용한 이중합성 거더의 수평접합면 구조거동에 관한 실험적 연구 (Experimental Study on Structural Behavior of Interfaces of Double Composite Girder Using the 80 MPa Concrete)

  • 양인욱;임얼;하태열
    • 한국산학기술학회논문지
    • /
    • 제17권4호
    • /
    • pp.400-413
    • /
    • 2016
  • 80 MPa급 고강도 콘크리트가 강거더의 압축 플랜지로 대체하는 아중합성 거더의 경우, 플랜지와 케이싱 및 케이싱과 바닥판 2개의 접합부 계면이 형성되는데 각 계면의 수평 전단 저항능력은 구조물의 안전성에 있어 중요한 요소이다. 본 연구는 계면 상세를 달리한 6개의 실험체를 도로교설계기준(한계상태설계법)에 따라 설계 및 제작하여 이중합성 보의 휨 파괴 대비 수평 전단에 대한 구조 성능 실험을 수행하였다. 실험체의 주요변수로 스터드 전단연결재의 저항계수, 바닥판 콘크리트 및 철근의 재료저항계수, 콘크리트 인장강도에 따른 부착계수, 케이싱 콘크리트의 표면 상태 그리고 수평전단철근의 간격을 고려하였다. 실험 결과, 강재 상부 플랜지와 고강도 케이싱의 계면이 고강도 케이싱과 바닥판 계면 보다 결합성이 큰 것으로 나타났다. 그리고 고강도 케이싱과 바닥판 계면에서는 케이싱 표면에 요철 또는 거칠기를 주는 것 보다 보수적으로 수평전단철근을 배근하는 것이 소성영역까지 합성 거동을 유지하는 것으로 나타났다.