• Title/Summary/Keyword: Sound absorptive area

Search Result 5, Processing Time 0.026 seconds

A Method to Arrange Absorptive Materials on Walls for Effective Interior Noise Control (효율적 실내 소음 저감을 위한 흡음재 분포 위치 결정 방법)

  • 김양한;조성호
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.4
    • /
    • pp.303-309
    • /
    • 2004
  • Absorptive material arrangement method for effective interior noise control is proposed. Sound field with arbitrary boundary condition is formulated by Kirchhoff-Helmholtz integral equation. A simple example such as a rectangular cavity will present physical meaning between changing boundary condition and control of sound field. The effect of changing boundary condition is expressed in modal admittance. From this formulation. an admittance map is presented. The admittance map is the figure to represent position where absorptive material is attached for effective interior noise control. The admittance map can be assigned to each resonant frequency. There. however, may be common area of those maps. Then, frequency robust arrangement of absorptive material in noise control will be presented.

A Method to Arrange Absorptive Materials on Walls for Effective Interior Noise Control (효율적 실내 소음 저감을 위한 흡음재 분포 위치 결정 방법)

  • Cho, Sung-Ho;Kim, Yang-Hann
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1702-1707
    • /
    • 2003
  • Absorptive material arrangement method for effective interior noise control is proposed. Sound field with arbitrary boundary condition is formulated by Kirchhoff-Helmholtz integral equation. A simple example such as a rectangular cavity will present physical meaning between changing boundary condition and control of sound field. The effect of changing boundary condition is expressed in modal admittance. From this formulation, an admittance map is presented. The admittance map is the figure to represent position where absorptive material is attached. The admittance map can be assigned to each resonant frequency. There, however, may be common area of those maps. Then, frequency robust arrangement of absorptive material in noise control will be presented.

  • PDF

Comparison of Acoustic Performance Depending on the Location of Sound Absorptive and Diffuser in Small Auditoriums Using 1/10 Scale Models (1/10 축소모형을 이용한 소공연장의 흡음재와 확산체의 적용위치에 따른 음향성능 비교)

  • Kim, Tae-Hee;Park, Chan-Jae;Park, Ji-Hoon;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.146-156
    • /
    • 2015
  • This study investigated how the location of sound absorptive materials and sound diffusers affects the acoustic performance of small auditoriums. It was conducted for a standard model established with the averaged dimension of 36 auditoriums which had opened since 2000 in Daehak-ro, Seoul. In this study, the installation area of finishing materials was calculated upon a back wall which had the smallest installation effective area of finishing materials. To analyze the changes of acoustic performance according to installation location of finishing materials, experiments were carried out using the 1/10 down scale models for 8 cases which were made by classifying the installation location of ceiling and side wall into the front, middle and rear part.The used acoustic parameters were reverberation time (RT), early decay time (EDT), clarity (C80), definition (D50) and speech transmission index (STI). In result, the index related to the amount of reverberant sound (RT, EDT) showed the great changes when evaluating it through just noticeable difference (JND), but the one related to clarity (C80, D50, STI) hardly indicated the changes. In case to obtain short reverberation time, it was most effective to control reverberation time through the side walls when installing sound absorptive and diffusive materials, and side wall front was the location which could get the shortest reverberation time.

Interior surface treatment guidelines for classrooms according to the acoustical performance criteria (학교 교실의 음환경 기준에 따른 실내마감 방안)

  • Ryu, Da-Jung;Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.2
    • /
    • pp.92-101
    • /
    • 2016
  • There are many results in which acoustical conditions of a classroom play an important role for studying effects and academic achievement of students. However, there are very few guidelines or design proposals which could make appropriate acoustic environment when classrooms are built or renovated. The present study suggests various design proposals satisfying acoustic standards of classrooms based on theoretical calculation and acoustic field experiments. At first, minimum area of sound absorption was calculated which is required to satisfy the acoustic standard for domestic middle and high schools. Also, room acoustic measurements were carried out in order to investigate the acoustic performance of an existing classroom by changing interior finishing materials on ceiling and rear walls. As a result, it was revealed that reverberation time standard below 0.8 s can be acquired even if there is no sound absorption on ceiling which is a general practice executed in Korea. Specially, it was found that if partial area of ceiling would be treated as reflective with the ratio of sound absorption and reflection as 2:1, almost similar acoustic parameters of $C_{50}$, $D_{50}$, RASTI (Rapid Speech Transmission Index) and higher sound levels could be acquired in comparison with the case of entire sound absorption on ceiling.

Noise Analysis and Reduction Methods of the All-in One Window Ventilation System (창호일체형 환기장치의 소음분석 및 저감방안)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.43-55
    • /
    • 2013
  • The window ventilation system based on the heat recovery device was developed which make air ventilation possible without opening the windows. However, mechanical and aerodynamic noises were come to pass which annoyed people in rooms. In the present study, noise of new window ventilation system was measured in both general room and anechoic chamber. Also, the noise path was detected to find cause of noise generation and vulnerable area of the device. Sound absorptive and insulation materials were applied to mitigate the noise. Finally, an alternative noise control method was suggested which can satisfy with the indoor noise standards. As a result, it was shown that the cause of noise was the low transmission loss in the ventilation system. As a result, it was shown that the main noise source of the ventilation system was the blower and the major cause of noise was the low transmission loss of the ventilation system. It is also concluded that the noise levels complies with the noise standards of 40 dBA when 2 mm rubber sheet is applied inside the ventilation system.