• Title/Summary/Keyword: Spherical Equivalent

Search Result 140, Processing Time 0.027 seconds

Predicting of Uncorrected Astigmatism from Decimal Visual Acuity in Spherical Equivalent

  • Moon, Byeong-Yeon;Kim, Sang-Yoeb;Cho, Hyun Gug
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.219-223
    • /
    • 2013
  • The purpose of this study was to determine the relationship between the spherical equivalent visual acuity (VA) and uncorrected astigmatism. On 108 emmetropic eyes, the spherical equivalent VA was measured for cross cylindrical lens (CC lens)-induced astigmatic eyes and the VA-astigmatism relation determined. On 158 astigmatic eyes, the spherical equivalent VA and corrected astigmatism were measured and the measured values were compared with the calculated values from the VA-astigmatism relation by correlation coefficient analysis. Subsequent to that, the relationship between spherical equivalent VA and uncorrected astigmatism was made. The relationship was fitted for an exponential equation. Correlation coefficient between calculated values by equation and measured values for astigmatic eyes was 0.991 (p<0.01). The relationship between the spherical equivalent VA and the uncorrected astigmatism was decided as follows (spherical equivalent VA / uncorrected astigmatism): 1.0 / 0.25 D, 0.9 / 0.50 D, 0.8 / 0.75 D, 0.7 / 1.00 D, 0.6 / 1.25 D, 0.5 / 1.50 D, 0.4 / 2.00 D, 0.3 / 2.50 D, 0.2 / 3.00 D, 0.1 / 4.00 D, and 0.05 / 4.75 D. In conclusion, the relationship table devised from this study is a useful reference for predicting uncorrected astigmatism by measurement of decimal VA in spherical equivalent.

Analysis of Refractive Error according to Aging in Young Children in South Korea (한국 어린이의 연령에 따른 굴절이상 분석)

  • Kim, Douk-Hoon;Kim, Dae-Nyoun
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Purpose. to describe the prevalence of refractive error according to aging in young children in South Korea. Methods : From July 2013 to June 2014, five hundred subjects( 250 male subjects, 250 female subjects; aged between 7 and 12 years) were performed in refraction test using the Auto-Refraction. Myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)${\leq}-0.50$ diopters, SE ${\geq}+2.00$ D, cylinder error ${\geq}0.75$ D and SE difference${\geq}1.00$ D between binocular eyes, respectively. Results. The refractive error by spherical equivalent among all subjects was myopia 80.41%, astigmatism 44.89%, emmetropia 18.27%, anisometropia 16.92%, and hyperopia 1.32%. The prevalence of myopia increased with age. but hyperopia was decrease. Myopia and astigmatism were much more common in male than females although the difference was not statically significant. Emmetropia and hyperopia were much more common in female than males although the difference was not statically significant. The prevalence of spherical equivalent was much common from -1.00 diopter to 0.99 diopter. On the other hand, the prevalence of myopia was much more than hyperopia. There was a statistical significance between 9 year and 10 year of female in the spherical equivalent power(p>0.05). In all another group of age, there was not a statistical significance as aging in spherical equivalent power(p>0.5). However, there was a statistical significance between male and female as age in the spherical equivalent power(P>0.01). Conclusions: Myopia was the most common refractive error in Korea young children, while hyperopia was decreased after 7 years. There was a statistical significance as age between male and female at spherical equivalent power(P> 0.01). these results suggested that the analysis of the refractive error as age at young children can give the useful diagnosis data for the correction of visual function.

Refractive Error in 7-9 Year-old Korea Children (7세부터 9세 사이의 한국인 어린이의 굴절 이상)

  • Kim, Douk-Hoon;Alberto, Mercedita O.
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.3
    • /
    • pp.203-208
    • /
    • 2014
  • Purpose. To analysis the refractive error in 7-9 year-old Korea children. Methods. From July 2013 to June 2014, two hundred eighty two subjects were performed in refraction test using the Auto-Refractometry. Results. The refractive error by spherical equivalent among all subjects was myopia 47.58%, emmetropia 42.35%, astigmatism 32.33%, and hyperopia 8.76%. Myopia was more common in female than males although the difference was not statically significant. The axis of astigmatism was with the rule in 65%, against the rule in 31.5%, and oblique in 3.5% There was a statistical significance between 7 year and 9 year of male in the spherical equivalent power(p=0.010). Also there was a statistical significance between 7 years and 9 years of female in the spherical equivalent power(p=0.036). However, there was not a statistical significance between male and female in spherical equivalent power(p>0.5). Conclusions. In this study, myopia was the most common refractive error. On the other hand, The prevalence of the axis of astigmatism was the with- the- rule. The spherical equivalent of refractive error was similar results between male and female. However The refractive error was different style with aging. these data suggested that the analysis of the refractive error at young children can provide the information of useful diagnosis for the correction of visual acuity.

Solution to Slow Down Myopia Progression

  • Jung, Ji-Won
    • Journal of Korean Clinical Health Science
    • /
    • v.8 no.1
    • /
    • pp.1386-1397
    • /
    • 2020
  • Purpose: To examine the effectiveness of various treatments; bifocal spectacles, orthokeratology, atropine, and time spent in outdoors; in slowing down the myopia progression for Asian adolescents (6-18age). Methods: The research focused on examining the most effective treatment in controlling myopia based on the literature sources that have been published. Through meta-analysis of various research papers that already has been done in this field, a lot of data was collected. For each treatment, the difference in axial length and spherical equivalent over time was measured and recorded. To quantitatively record the difference, both axial length and spherical equivalent was determined by value of control group value of treatment group. The paper compared the effectiveness of each treatment based on the data that was measured. Results: Adolescents who chose to spend time outdoors in order to slow down myopia progression had axial length difference of 0.03 mm and spherical equivalent difference of 0.17 D. Adolescents that used atropine had axial length difference of 0.36 mm and spherical equivalent difference of 0.92 D. Bifocal spectacle resulted in axial length difference of 0.21 mm and spherical equivalent difference of 0.59 D, and for orthokeratology 0.23 mm and 0.04 D, respectively. Axial length wise, myopia was most controlled by the atropine since there was a greatest difference between the group that got the treatment and the group that did not have the treatment. According to the spherical equivalent difference data, myopia was most controlled by atropine. Conclusion: Atropine showed the most effective result in controlling myopia among the four treatment. Again, compared to other three treatment, using atropine appeared to have greatest ability in slowing down myopia progression since adolescents who were treated with atropine had greatest difference from adolescents in the control group that had the same condition but didn't get the treatment. However, every treatment was only used for 2 or 3 years which is quite short time period to measure the long term effect of the four treatments. Also, since atropine is a pharmaceutical method to control myopia, it may harm adolescents' eyes compared to optical or environmental treatment.

Analysis of Refractive Status between Urban and Rural Region in 13-year-old Children (도시와 농촌의 13세 어린이에 대한 굴절상태 분석)

  • Kim, Douk-Hoon;Kim, Jung-Sook
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.1
    • /
    • pp.808-815
    • /
    • 2017
  • Purpose. To analyze the refractive status between urban and rural regions, of children in Korea, in the age group of 13. Methods. From October 2016 to January 2017, forty subjects( 20 male subjects, 20 female subjects; 13 years) were performed in refraction test using the Auto-Refraction. Myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)${\leq}-0.50$ diopters, SE ${\geq}+1.00D$, cylinder error ${\geq}0.75D$ and SE difference${\geq}1.00D$ between binocular eyes, respectively. Results. The refractive error by spherical equivalent among all subjects was myopia 76.25%, astigmatism 35%, emmetropia 16.25%, anisometropia 8.75%, and hyperopia 5%. The prevalence of myopia and astigmatism were much more common in urban than rural region although the difference was not statically significant. Emmetropia and astigmatism were much more common in rural region than urban although the difference was not statically significant. The prevalence of spherical equivalent was much common from -1.00 diopter to -4.00 diopter. On the other hand, the prevalence of myopia was much more than hyperopia. There was a statistical significance between OD and OS of rural region in the spherical equivalent power(p<.000). Also, There was a statistical significance between OD and OS of urban region in the spherical equivalent power(p<.004). Therefore, there was a significant statistical similarity between urban and rural regions on the OD and OS in the spherical equivalent power. On the other hand, There was a significant statistical similarity between urban and rural regions of the OD and OS in the astigmatism power(p<0.000). However, in the rural and urban regions there was not statistical significance in the OD and OS concerning the spherical equivalent power and astigmatism power (p>0.1). Conclusions. Myopia was the most common refractive error in Korea young children. while hyperopia was few. There was not a statistical significance as age between rural and urban at spherical equivalent power( P> 0.01). These results suggested that the analysis of the refractive status at young children can give the useful diagnosis data for the correction of visual acuity.

Analysis of refraction status on the Presbyopia in Korea (한국인 노안 굴절상태 분석)

  • Kim, Douk-Hoon;Lee, Min-Ho
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.2
    • /
    • pp.1337-1344
    • /
    • 2019
  • Purpose. This study was the analyze the refractive status of presbyopia in Korea. Methods. The subjects was from November 2018 to October 2019, two hundred thirty four subjects( 117 male subjects, 117 female subjects; from 40-year old to 88-year old ) were performed in refraction test using the Auto-Refraction(Speed -K model, Japan). The myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)≤-0.50 diopters, SE ≥+1.00 D, cylinder error ≥0.75 D and SE difference≥1.00 D between binocular eyes, respectively. Results. The refractive status by spherical equivalent among all subjects was myopia 61.43%, astigmatism 86.86%, emmetropia 19.18%, anisometropia 12.07%, and hyperopia 18.54. The prevalence of myopia and astigmatism were much more common in male. However, The hyperopia and astigmatism were much more common in female. The prevalence of spherical equivalent was much common from -0.50 diopter to -5.00 diopter. On the other hand, the prevalence of astigmatism and myopia was much more than hyperopia in all subjects. There was a statistical significance between OD and OS of the female and male in the spherical equivalent power(p<.000). However, there was not statical significant between female and male of OD and OS in the spherical equivalent power(p<.070). On the other hand, The prevalence of againest axis in astigmatism was more common in all subjects. In ADD power for the near vision correction, the female was much more diopter than male. Conclusions. These results suggested that the analysis of the refractive status on the presbyopia in Korea can give the useful diagnosis data for the correction of visual acuity at near distance.

Study on the Analysis of Corneal Variation by Refractive Error (굴절이상에 의한 각막 변화도 분석에 관한 연구)

  • Lee, Hae-Jung;Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.485-490
    • /
    • 2014
  • The purpose of this Study investigated corneal power, corneal astigmatism and corneal axis according to spherical equivalent of refractive error. We measured spherical equivalent, corneal power and corneal astigmatism in 100 subjects from January 2014 to July 2014. Measured spherical equivalent of refractive error were $-3.01{\pm}3.79D$, corneal power of $43.79{\pm}1.60D$ and corneal astigmatism of $-1.17{\pm}0.79D$ respectively. Prevalence of spherical equivalent of refractive error were as follows : myopes (61%), emmetropes (22%), hyperopes(17%). Corneal astigmatism of refractive error greater than +0.75D was 63% and prevalence of corneal astigmatism were as follows : with-the-rlue astigmatism (84.13%), against-the-rule astigmatism(9.52%) respectively. Corneal power by spherical equivalent increased from hyperopia to myopia. Between spherical equivalent of refractive error and the mean corneal power was significant correlation(r=-0.25, p=0.01). A correlation were found between corneal power and spherical equivalent of refractive error in adults. They have the highest distribution of prevalence myopia among the refractive error. When the refractive error was increased, we found that corneal power was steeper. It is recognized that this can be refractive error factor and correct visual function is considered.

Assessment of Equivalent Elastic Modulus of Perforated Spherical Plates

  • JUMA, Collins;NAMGUNG, Ihn
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.8-17
    • /
    • 2019
  • Perforated plates are used for the steam generator tube-sheet and the Reactor Vessel Closure Head in the Nuclear Power Plant. The ASME code, Section III Appendix A-8000, addresses the analysis of perforated plates, however, this analysis is only limited to the flat plate with a triangular perforation pattern. Based on the concept of the effective elastic constants, simulation of flat and spherical perforated plates and their equivalent solid plates were carried out using Finite Element Analysis (FEA). The isotropic material properties of the perforated plate were replaced with anisotropic material properties of the equivalent solid plate and subjected to the same loading conditions. The generated curves of effective elastic constants vs ligament efficiency for the flat perforated plate were in agreement with the design curve provided by ASME code. With this result, a plate with spherical curvature having perforations can be conveniently analyzed with equivalent elastic modulus and equivalent Poisson's ratio.

Evaluation of Reliability for Combined Refractive Power of Lenses in an Automatic Phoropter (자동포롭터 내부렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2015
  • Purpose: To evaluate the reliability of refractive power by comparing the marked refractive power in an automatic phoropter and actually measured spherical/cylindrical refractive power. Methods: Actual refractive power of minus spherical lens and cylindrical lens in an automatic phoropter was measured by a manual lensmeter and compared with the accuracy of marked refractive power. Furthermore, combined refractive power and spherical equivalent refractive power of two overlapped lenses were compared and evaluated with the refractive power of trial lens. Results: An error of 0.125 D and more against the marked degree was observed in 70.6% of spherical refractive power of spherical lens which is built in phoropter, and the higher error was shown with increasing refractive power. Single cylindrical refractive power of cylindrical lens is almost equivalent to the marked degree. Combined spherical refractive power was equivalent to spherical refractive power of single lens when spherical lens and cylindrical lens were overlapped in a phoropter. Thus, there was no change in spherical refractive power by lens overlapping. However, there was a great difference, which suggest the effect induced by overlapping between cylindrical refractive power and the marked degree when spherical lens and cylindrical lens were overlapped. Spherical equivalent refractive power measured by using a phoropter was lower than that estimated by trial glasses frame and marked degree. The difference was bigger with higher refractive power. Conclusions: When assessment of visual acuity is made by using an automatic phoropter for high myopes or myopic astigmatism, some difference against the marked degree may be produced and they may be overcorrected which suggests that improvement is required.

Acoustic holography for an engine radiation noise using equivalent sources (등가음원을 이용한 엔진 방사 소음의 음향 홀로그래피에 대한 연구)

  • Jeon, In-Youl;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1101-1106
    • /
    • 2004
  • This study presents the reconstruction of sound field radiated from an automotive engine using equivalent sources. Basic concept of the method presented is to replace the engine noise source with elementary sources of multipoles, e.g., monopoles and dipoles. The so-called Helmholtz equation least-squares (HELS) method can reconstruct the sound radiation fields from spherical geometries in a series expansion of spherical Hankel functions and spherical harmonics. In this paper, multi-Point, multipole equivalent sources are employed to reconstruct the sound field radiated from an automotive engine with a fixed rotation speed. To ensure and improve the accuracy of reconstruction, the spatial filters of multipole coefficients and wave-vectors are adopted for suppressing the adverse effect of high-order multipoles. Optimal filter shapes are designed with regularization parameters minimizing the generalized cross validation (GCV) function between actual and reproduced model. After regeneration of field pressures using the proposed method as many as necessary, the vibro-acoustic field of an engine could be reconstructed by using the BEM-based near-field acoustic holography (NAH) technique in a cost-effective manner.

  • PDF