• Title/Summary/Keyword: Sprayed FRP

Search Result 12, Processing Time 0.032 seconds

Evaluation on Strengthening Capacities and Rebound Rate of Structures with Sprayed FRP (분사식 FRP에 의한 구조물의 보강 성능 및 반발률 평가)

  • Han, Seung-Chul;Yang, Jun-Mo;Yoon, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.193-202
    • /
    • 2008
  • This paper investigates experimentally the confining effect, strengthening capacity and rebound rate of sprayed Fiber-Reinforced-Polymer (SFRP). From the method, resin and chopped fibers are sprayed separately from the nozzle with high pressure, and then they are attached to the concrete surface, so structure could be repaired. To evaluate the strengthening effect of sprayed FRP, cylindrical specimens and beam specimens were strengthening with SFRP. As main material of FRP, glass fiber and polyester resin are used. To investigate the optimum condition of sprayed FRP, the effects of fiber length, coating thickness, fiber volume ratio and concrete strength were examined. Capacities of sprayed FRP method were also compared to the FRP sheet method. In case of the sprayed FRP, rebound rate is important parameter considering economical efficiency and constructibility, so rebound rate of was discussed. From the test results, optimum conditions of sprayed FRP were determined. SFRP method showed superior strengthening capacities than FRP sheet method.

Structural Performance of Reinforced Concrete Beams Strengthened with Sprayed Fiber Reinforced Polymers (Sprayed FRP로 보강된 철근콘크리트 보의 보강성능에 관한 연구)

  • Lee, Kang-Seok;Son, Young-Seon;Lee, Moon-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.421-431
    • /
    • 2007
  • The main purpose of this study is to develop a sprayed FRP repair and strengthening method, which is a new technique for strengthening the existing concrete structures by mixing one of the carbon or glass chopped fibers and one of the epoxy or vinyl ester resins with high-speed compressed air in open air and randomly spraying the mixture onto the concrete surface. At present, the sprayed FRP repair and strengthening method using the epoxy resin has not been fully discussed. In order to investigate the material property of the sprayed FRP, this study carried out tensile tests of the material specimens, which were changed with the combinations of various variables including the length of chopped fiber and the mixture ratio of chopped fiber and resin. These variables were set to have the equal material strength, compared with that of one layer of the FRP sheet. As a result, the optimal length of glass and carbon chopped fibers was fumed out to be 38 mm, and the optimal mixture ratio between chopped fiber and resin was also turned out to be 1 : 2 from each variable. And also, the thickness of the sprayed FRP to have the equal strength to one layer of the FRP sheet was finally calculated. In is study, a series of experiments were carried out to evaluate the strengthening effects of flexural beams, shear beams and damaged beams strengthened with the sprayed FRP method, respectively. The results revealed that the strengthening effects of the flexural and shear specimens were reasonably similar to those of the FRP sheet, and the developed Sprayed FRP technique is able to be used as a strengthening scheme of existing RC building.

Repair and Strengthening Methods for Concrete Structures using Sprayed Fiber Reinforced Polymers - Material Property of Sprayed FRP - (Sprayed FRP 공법에 의한 콘크리트 구조물의 보수.보강법 개발에 관한 연구 - Sprayed FRP를 구성하는 재료특성에 관한 연구 -)

  • Lee, Li-Hyung;Lee, Kang-Seok;Son, Young-Sun;Byeon, In-Hee;Lim, Byung-Ho;Na, Jung-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.141-144
    • /
    • 2006
  • The main purpose of this study is to develop a Sprayed FRP repair and strengthening method, which is a new technique for strengthening the existing concrete structures by mixing carbon or glass shot fibers and the epoxy or vinyl ester resins with high-speed compressed air in open air and randomly spraying the mixture onto the concrete surface. At present, the Sprayed FRP repair and strengthening method using the epoxy resin has not been fully discussed. In order to investigate the material property of Sprayed FRP, this study carried out tensile tests of the material specimens which are changed with the combinations of various variables such as the length of shot fiber and mixture ratio of shot fiber and resin. These variables are set to have the material strength equal to one layer of the FRP sheet. As a result, the optimal length of glass and carbon shot fibers were derived into 3.8cm, and the optimal mixture ratio was also deriver into 1:2 from each variable. And also, the thickness of Sprayed FRP to have the strength equal to one layer of FRP sheet was finally calculated.

  • PDF

Structural Performance of Reinforced Concrete Shear Columns Strengthened with Sprayed Fiber Reinforced Polymers (Sprayed FRP로 보강된 철근 콘크리트 전단기둥의 보강성능 평가)

  • Lee, Kang Seok;Byeon, In Hee;Lee, Moon Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.132-142
    • /
    • 2007
  • In this study, a structural performance of R/C columns controlled by shear, strengthened with Sprayed FRP, was investigated. For this purpose, six 2/3-scaled column specimens were designed and tested by the pseudo-static reversed cyclic load under a constant axial load, which is 10% of the nominal axial strength of the column. Four specimens were strengthened by Sprayed FRP with different combinations of short fibers (carbon or glass) and resins (epoxy or vinyl ester). For comparison purpose, tests of a specimen strengthened with carbon fiber sheet (CFS) and a control specimen without strengthening were carried out, respectively. The result reveals that shear strengths and ductility capacities of columns strengthened with Sprayed FRP improved remarkably, compared to those of the control column, and the Sprayed FRP technique developed in this study is able to use the strengthening scheme of existing R/C columns.

Repair and Strengthening Methods for Concrete Structures using Sprayed Fiber Reinforced Polymers - Strengthening Performance of Reinforced Concrete Beams - (Sprayed FRP 공법에 의한 콘크리트 구조물의 보수.보강법 개발에 관한 연구 - 철근콘크리트 보의 보강성능 평가 -)

  • Lee, Kang-Seok;Son, Young-Sun;Byeon, In-Hee;Lee, Moon-Sung;Na, Jung-Min;Lee, Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.133-136
    • /
    • 2006
  • The main purpose of this study is to develop a Sprayed FRP repair and strengthening method, which is a new technique for strengthening the existing concrete structures by mixing carbon or glass shot fibers and the epoxy or vinyl ester resins with high-speed compressed air in open air and randomly spraying the mixture onto the concrete surface. At present, the Sprayed FRP repair and strengthening method using the epoxy resin has not been fully discussed. In this study, a series of experiments are carried out to evaluate the strengthening effects of the flexural and shear concret beams strengthened with the Sprayed FRP method. The results revealed that the strengthening effects of the flexural and shear specimens are similar, compared to those of the FRP sheet.

  • PDF

Micromechanics-based Analysis on Tensile Behavior of the Sprayed FRP Composites with Chopped Glass Fibers (유리단섬유로 보강된 분사식 섬유보강 복합재료의 인장거동에 관한 미세역학 기반 해석)

  • Yang, Beom-Joo;Ha, Seong-Kook;Lee, Haeng-Ki
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.3
    • /
    • pp.211-217
    • /
    • 2012
  • In this paper, experimental tests and theoretical studies were carried out to evaluate the tensile behavior of the sprayed FRP composite with chopped glass fiber. For this, a series of tensile strength tests with various strain rates were conducted on the specimens of the matrix and sprayed FRP composite. Sprayed FRP composite contained chopped glass fibers with fiber length of 15mm and a specific volume fraction of fibers of 25 %. An inverse simulation was conducted to simulate the strain rate sensitivity based on the present experimental data of the epoxy resin. The simulated viscosity value is adapted to the micromechanics-based viscoelastic damage model(Yang et al., 2012), and the overall tensile behavior of sprayed FRP composites is predicted. It was seen from the comparative study between present experimental data and predication results that the proposed methodology can be used to predict the viscoelastic behavior of the sprayed FRP composite.

Performance Evaluation of Structure Strengthening Using Sprayed FRP Technique (분사식 FRP공법을 이용한 구조물 보강 성능평가)

  • Chang, Chun-Ho;Jang, Kwang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.126-136
    • /
    • 2009
  • The sprayed FRP strengthening technique is combining the Glass fiber and Polyester resin in open air and spraying randomly at concrete's surface with high-speed compressed air. Then it strengthens the structures with a new technique evaluated the structural performance. We applied it to concrete beam and tested for flexural strength, depended on Korea Standard(KS F 2408). Then based on the result of flexural strength, the properties were proposed that applying to structures. Based on the experiment, we have evaluated structural performance by the experiment. 1/5 scale prestressed concrete I-beam were made by Korean Highway's typical drawing in 1993. With these test results, 49.8% increased in flexural strength, improvement of the behavior of serviceability state, and strengthening was surely effective for controlling deflection and crack of structure. Consequently, it can be summarized that Sprayed FRP technique has prospect to improve the performance of structure.

Repair and Strengthening Methods for Concrete Structures using Sprayed Fiber Reinforced Polymers - Strengthening performance of Reinforced Concrete Shear Columns - (Sprayed FRP 공법에 의한 콘크리트 구조물의 보수.보강법 개발에 관한 연구 - 철근콘크리트 전단기둥의 보강성능 평가 -)

  • Lee, Kang-Seok;Byeon, In-Hee;Son, Young-Sun;Lee, Moon-Sung;Li, Cheng-Hao;Lee, Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.137-140
    • /
    • 2006
  • In this study, a seismic performance of reinforced concrete columns strengthened by a sprayed fiber reinforced polymer (SFRP) is investigated. For this purpose, six column specimens approximately scaled into 2/3, are designed and tested under a constant axial load, 10% of the nominal axial strength of column, and pseudo-static reversed cyclic lateral loading system. Four specimens are strengthened by Sprayed FRP using different combinations of short fibers (carbon or glass fiber) and resins (epoxy or vinyl esther). For comparison, the test investigated in this study also includes a specimen strengthened using carbon fiber reinforced polymer (CFRP), and also a control specimen without strengthening. The results revealed that specimens strengthened using SFRP showed a improved structure behavior, compared to control specimen, in terms of strength, ductility, lateral drift capacity, and energy-absorbtion capacity. In addition, compared to the specimen strengthened using CFRP, Sprayed FRP-strengthened specimens reasonably showed a equivalent seismic performance.

  • PDF

Repair and Strengthening Method Using Near Surface Mounted FRP Rods and Overlay (FRP Rod를 이용한 표면매립 및 단면 확대 복합 보수$\cdot$보강 공법)

  • Hwang Gum-sic;Park Chin-ki;Won Jong-pil
    • Composites Research
    • /
    • v.18 no.4
    • /
    • pp.66-74
    • /
    • 2005
  • This paper reports new repair and strengthening mathod using improved material. This mathod have two type according to covering thickness of reinforcement. One type is near surface mounted FRP rod. Anther type is overay. Fiber Reinforced Plastic (FRP) materials has become very popular in recent years. FRP material used to rehabilitate many types of structures with superior characteristics such as high strength and stiffness and corrosion resistance. This strengthening mathod were used FRP rod which have better bond and shear strangth than current FRP rod. Development of FRP rod due to 3-D winding system. In addition, Ductile hybrid FRP has a certain plastic deformation and an elongation greater than 3% at maximum load is usually required for steel reinforcement in concrete structures. Moerover this mathod can be effective repair of base concrete by sprayed polymer mortar.

Reinforcing System(MFRI) for Concrete Structure using FRP ROD & High-performance Mortar (섬유복합재봉(FRP ROD)과 고강도 모르터를 이용한 철근 콘크리트 구조물의 휨 보강공법(MFRI) 공법)

  • Bae Ki-Sun;Park Sing-Hun;Lee Sang-Uk
    • Composites Research
    • /
    • v.18 no.4
    • /
    • pp.59-65
    • /
    • 2005
  • This report is on the Reinforcing System(MFRI) for Concrete Structure using FRP ROD & High-Performance Mortar. The main characteristic of this system is as follow. First, the fiber rods in this system have seven times greater tensile strength than general reinforcing steel bars(re-bar) and the weight is a fifth lighter. Camels coated on the fiber rods' surfaces to improve adhesive strength and pull-out strength. Second, high strength shotcrete mortar is has very good workability and low rebound rate. After installing the Fiber Rods, Shotcrete mortar Is applied or sprayed to finish reinforcement. Finally, MFRI system has excellent fire-resisting performance and sogood tolerance against external environment by inserting fiber rods and reinforcing materials into mortar which has high compressive strength. It is applied to bridge slab, utility box and tunnel of civil engineering works, and beam and slab of building structures.