• 제목/요약/키워드: Staircase

검색결과 169건 처리시간 0.023초

Effect of staircase on seismic performance of RC frame building

  • Kumbhar, Onkar G.;Kumar, Ratnesh;Adhikary, Shrabony
    • Earthquakes and Structures
    • /
    • 제9권2호
    • /
    • pp.375-390
    • /
    • 2015
  • Staircase is a vertical transportation element commonly used in every multistoried structure. Inclined flights of staircase are usually casted monolithically with RC frame. The structural configuration of stairs generally introduces discontinuities into the typical regular reinforced concrete frame composed of beams and columns. Inclined position of flight transfers both vertical as well as horizontal forces in the frame. Under lateral loading, staircase in a multistory RC frame building develops truss action creating a local stiffening effect. In case of seismic event the stiff area around staircase attracts larger force. Therefore, special attention is required while modeling and analyzing the building with staircase. However, in general design practice, designers usually ignore the staircase while modeling either due to ignorance or to avoid complexity. A numerical study has been conducted to examine the effect of ignoring staircase in modeling and design of RC frame buildings while they are really present in structure, may be at different locations. Linear dynamic analysis is performed on nine separate building models to evaluate influence of staircase on dynamic characteristics of building, followed by nonlinear static analysis on the same models to access their seismic performance. It is observed that effect of ignoring staircase in modeling is severe and leads to unsafe structure. Effect of location and orientation of staircase is also important in determining seismic performance of RC frame buildings.

계단의 적정치수 계획에 관한 연구 -계단에서의 안전을 위한 단높이, 단너비, 경사도의 최소치수를 중심으로- (A Study on the Design of Optimum Dimension of Staircase -Focused on the Minimum Dimension of Riser, Tread and Slope for Safety on Staircase-)

  • 김용환
    • 한국주거학회논문집
    • /
    • 제14권5호
    • /
    • pp.105-116
    • /
    • 2003
  • The purpose of this study is to suggest the method of prevention of staircase accidents, and to make housing environment better through researching the dimension of a housing staircase for Korean. The scope and method of this thesis is to investigate the dimension limits of a staircase (slope, minimum width of tread, maximum height of riser), and to analyze the characteristics of foot condition (jutting rate, foot angle, ball joint, nosing clearance, clearance distance) using the experiment which takes a photograph of foot motion during walking stairs. The results of this thesis are as follows. The slope of a staircase in house is $32.3^{\circ}$$^{\circ}$-$42.1^{\circ}$$^{\circ}$. The riser should be less than 190 mm. The minimum size of tread is 210 mm and proper size is 270 mm.

굴뚝효과와 외부출입문 개방을 고려한 부속실 제연 (Vestibule Smoke Control Considering the Stack Effect and the Opening of the Outside Door)

  • 김용광;손주달;김서영;공하성
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.15-24
    • /
    • 2024
  • The purpose of this study is to improve the stack effect of the staircase and the failure to take into account the opening of the outside door of the staircase, which are the disadvantages of the existing smoke control only vestibule. As a result of the study, the new vestibule and the staircase simultaneous smoke control are equipped with an exhaust flap damper with an effective opening area of about 0.25 m2 in the upper part of the staircase, and a ventilator-type air supply fan of about 5 m3/s in the lower part, and take measures to prevent overpressure in the staircase. If you use the new simultaneous smoke control method of the vestibule and staircase, you can achieve the following effects. First, it is possible to open the external entrance door. Second, it can reduce the stack effect. Third, the staircase door closes automatically without fail. And a new method of preventing overpressure was proposed for the vestibule.

Seismic response of substandard RC frame buildings in consideration of staircases

  • Karaaslan, Ayberk;Avsar, Ozgur
    • Earthquakes and Structures
    • /
    • 제17권3호
    • /
    • pp.283-295
    • /
    • 2019
  • During the seismic performance assessment of existing buildings, staircases are generally not taken into account as structural members but as dead load. Staircases, as secondary structural members, not only serve for connecting successive floors but also provide considerable amount of strength and stiffness to the building which can modify its seismic behaviour considerably. In this parametric study, the influence of staircases on the seismic response of substandard RC frame buildings which differ in number of storey and span, presence of staircase and its position has been examined. Modal Analyses and bi-directional Non-Linear Time History Analyses (NLTHA) were conducted to compare several engineering demand parameters (EDPs) such as inter-storey drift ratio (ISDR), floor accelerations, modal properties, member shear forces and plastic hinge distribution. Additionally, short column effect, variation in shear forces of columns that are attached to the staircase slab, failure and deformation in staircase models have also been investigated. As the staircase was considered in the analytical model, a different damage pattern can be developed especially in the structural components close to staircase.

Fabrication of a Staircase Coil with Improved SNR and Image Uniformity by Structural Changes of a Conventional Birdcage Coil at 1.5T MRI

  • Ryang, Kyung-Seung;Shin, Yong-Jin
    • 한국자기공명학회논문지
    • /
    • 제7권1호
    • /
    • pp.25-36
    • /
    • 2003
  • The performance of radio frequency (RF) coils, used in MRI units, is determined by the image uniformity and the signal-to-noise ratio (SNR). Birdcage and surface coils are commonly used. A birdcage coil provides a good image uniformity while a surface coil produces a high SNR. In this study, therefore, a staircase coil was designed from a standard version of a birdcage coil, with some structural changes to increase SNR while maintaining image uniformity. In phantom experiments, the improvement of the image to uniformity and the SNR increase of the staircase coil compared with the values for the birdcage coil were about 3.5% and 35%, respectively. In clinical experiment, the SNR increase of the staircase coil, compared with the value for the birdcage coil was about 40% in bone, muscle and blood-vessel tissues. These results show that the performance of the staircase coil was very improved over the standard birdcage coil in terms of SNR, and that image uniformity was maintained. Therefore, the staircase coil designed by this study should be useful in experimental and clinical l.5T MRI systems, and this coil offers an alternative method of quadrature detection.

  • PDF

Evaluating Staircase Safety Using BIM-based Virtual Simulation: Focusing on the Elderly in the Republic of Korea

  • Yang, Hyuncheul;Jeong, Kwangbok;Kim, Sohyun;Lee, Jaewook
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.1146-1153
    • /
    • 2022
  • As the population is aging, accidents involving elderly people are also increasing (2014:11,667 persons; 2018: 11,797 persons). In the case of the elderly population, falling accidents are the primary direct or indirect causes of death; in particular, they face an elevated risk of staircase falls. This study proposes a method of evaluating the safety of staircases using Building Information Modeling (BIM)-based virtual simulation. By making a virtual user with the behavioral characteristics of the elderly respond to a staircase in a BIM model, its safety performance can be evaluated. The evaluation criteria were derived from regulations, elements, and characteristics relevant to the safety of staircases. To validate the proposed method, safety evaluation tests were simulated on actual staircases. The evaluation result of the test simulation shows the safety scores of 1.97 points for the elderly user and 2.95 points for the average male adult user against a required safety score of a minimum of 2 points. That is, safety is relative to users as the safety of the same staircase can be different depending upon the different behavioral characteristics of users. The study suggests that the risk of staircase-related fall accidents to the elderly can be reduced by improving staircase designs through the proposed method.

  • PDF

계단이 포함된 건물 내부의 경로손실 예측과 측정 (Prediction and Measurement of the Path Loss in a Building including the Staircase)

  • 최태관;김성진;김채영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.219-222
    • /
    • 1999
  • A SBR/Image ray-tracing technique using triangular ray tubes to predict the effects of walls. rooms. floors, and staircase is considered. Suggested technique is very efficient to estimate the path loss in three-dimensional buildings including the staircase. The model to predict the path loss through walls and floors in a multifloored building is presented. Measurements are made for three corridors having the staircase at 850 MHz, Measured data shows a close agreement with a simulated data.

  • PDF

계단형 스태거드 데이터 방송 전송방식을 이용한 주문형 비디오 서비스 (Staircase Staggered Data Broadcasting and Receiving Scheme for Popular Video Services)

  • 김홍익;박승권
    • 한국통신학회논문지
    • /
    • 제31권10B호
    • /
    • pp.919-928
    • /
    • 2006
  • 정보통신 기술의 발달로 주문형 비디오(VoD) 서비스는 활성화되고 있다 주문형 비디오 시스템 설계를 위해서는 정해진 대역폭을 이용하여 시청자의 대기시간과 버퍼의 량을 줄이는 것이 중요한 요소다. 하지만 기존의 제안된 많은 주문형 비디오 방법들의 우수한 효율성을 보여주지만 높은 복잡도 때문에 구현이 어렵다. 이러한 이유로, 최근에는 주문형 비디오 방법의 복잡도를 줄이면서 대역폭 효율이 우수한 방법에 대해서 많은 연구가 진행되고 있다. 본 논문에서는 대역폭의 효율성도 높이면서 기존의 주문형 비디오 방법들의 복잡성을 크게 줄인 계단형 스태거드(Staircase Staggered) 방식을 제안한다. 논문에서 제안하는 계단형 스태거드 방식은 Staircase Broadcasting의 높은 대역폭 효율과 Staggered Broadcasting 방식의 간단한 구조적 특징을 한꺼번에 가지고 있는 주문형 비디오 방법이다. 모의실험 결과 제안된 방식은 시청자 대기시간이 Staircase Broadcasting 방식과 거의 수렴하고, 시청자 버퍼 요구량은 매우 낮게 나타났다. 그리고 제안된 방식은 비디오 분할에 따라서 시청자의 대기시간과 필요한 버퍼량을 조절 할 수 있기 때문에 주문형 비디오 방식이 적용되는 환경에 따라서 조절해서 적용이 가능하다. 또한 주문형 비디오 방식의 복잡성도 함께 줄일 수 있는데, 제안된 방식은 비디오 데이터 세그먼트 수를 크게 줄이고, 복잡한 채널 관리를 줄였으며, 사용하는 채널의 수도 크게 감소시켰다.

2017년 포항지진으로 피해를 입은 국내 필로티형 건물의 지진 거동 (Seismic Behavior of Domestic Piloti-type Buildings Damaged by 2017 Pohang Earthquake)

  • 김태완;추유림;김승래;번다리 디워스
    • 한국지진공학회논문집
    • /
    • 제22권3호
    • /
    • pp.161-168
    • /
    • 2018
  • Pohang earthquake occurred on November 15, 2017, with a magnitude of 5.4. The damage of the structure caused by the Pohang earthquake was the most significant in 4-story piloti-type buildings, where the damage patterns were different according to the location of columns and walls at the first story. One building with a staircase at a corner shows shear failure at columns, and Another building with a staircase in the middle shows no failure or shear failure at staircase walls. Therefore, two different piloti-type buildings were selected; one has a staircase at a corner and another has in the middle, and the seismic behavior of the buildings were examined by nonlinear dynamic analysis applying a ground motion measured at Pohang. Analytical model well simulated the actual behavior of the piloti-type buildings during the earthquake. Analysis results showed that walls have an insufficient shear strength wherever the location of the staircase is and columns with insufficient transverse reinforcement could be failed when the staircase is located at a corner. Conclusively, structural engineers should design columns and walls in piloti-type buildings to possess sufficient capacity according to the location of staircase.

수축과 활동전압의 Staircase 현상에 대한 Ca-전류 및 세포내 $Ca^{2+}$ 농도 변화의 영향 (Effects of the Changes in Ca-current and Intracellular Ca-concentration on the Contraction and Action Potential Staircase)

  • 박춘옥;서인석;호원경;엄융의;김우겸
    • The Korean Journal of Physiology
    • /
    • 제23권2호
    • /
    • pp.301-312
    • /
    • 1989
  • It well known that the magnitude of contraction and the shape of action potential depend upon the stimulation frequency and the duration of resting period (positive and negative staircase). Although the underlying mechanism of the staircase phenomenon is not fully understood, it has been suggested that staircase could be related to the intracllular $Ca^{2+}$ concentration. In order to elucidate the role of intracellular $Ca^{2+}$ on the contraction and action potential staircases, we examined the effects of 1 mM 4-aminopyridine (4-AP), 0.5 uM verapamil, 1 uM ryanodine, or reduction of extracellular Na concentration to 30% $(substituted\;by\;equimolar\;Li^+)$ in small atrial strips of the rabbit $(3{\times}10\;mm)$. The results obitained were as follows; 1) When the stimulation frequency was increased from 0.1 Hz to 2 Hz, positive staircase of the contraction and elevation of plateau level in action potential were found in control and the conditions of Na reduction and treatments of 4-AP, verapamil and ryanodine. 2) When stimulation frequency returned to 0.1 Hz from 1 min rest just after 2 Hz stimulation fer 1 min, the magnitudes of initial few contractions were larger than that of steady state contraction (post-rest potentiation) except, ryanodine or Na-reduction groups. 3) Negative staircase of contraction was developed in control and 4-AP group at post-rest 0.1 Hz stimulation and the plateau level of the action potential was decreased at the same time. But the reduction of contraction or the plateau level was much smaller in 4-AP group and than in control. From the above results it can be concluded that contraction and action potential staircase is dependent upon transmembrane $Ca^{2+}-current\;and\;Ca^{2+}$release from the SR.

  • PDF