• 제목/요약/키워드: Standard Method of Measurement

검색결과 1,491건 처리시간 0.028초

유량계 교정장치의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Flowmeter Calibrator)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.561-571
    • /
    • 2001
  • The standard uncertainty of flowrate measurement is obtained by combining that of independent variables. Gravimetric and volumetric method were applied to determine the flowrate and the standard uncertainties of flowrate measurement by both methods were evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainties of determining the flowrate were estimated from the sensitivity coefficient and the standard uncertainty of independent variables. For practical application, the methods for evaluating and expressing uncertainty in flow measurement were discussed. It was found that the uncertainties of the weighing and time measurement in gravimetric method, the volume and time measurement in volumetric method have dominant influence on that of flowrate measurement. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of flowrate measurement is shown clearly.

석유화학 플랜트 EPC 사업의 진도율 산정표준의 제안 (A Standard Method for Progress Measurement in a Petrochemical Plant EPC Project)

  • 조홍연;유호선
    • 플랜트 저널
    • /
    • 제7권4호
    • /
    • pp.77-87
    • /
    • 2011
  • In proportion to continuing growth of overseas plant market and the trend of its mega scale of the project, the importance of management is significantly emphasized for the successful execution of the project. And it is recognized that progress control is the most important management item amongst the others in the management. Progress control is importance of progress measurement for performance measurement and process control of project, but it is hardly obtainable securing the objectivity in the progress measurement since the progress measurement are being applied differently in accordance with the project conditions and the experience level of the person in charge for the progress control. This study has conducted as following to propose a standard method for progress measurement in a petrochemical plant protect. Domestic and overseas plant projects are investigated variously with the applied method of progress measurement, and the deduced problem of progress measurement. And then standard method for progress measurement of engineering, procurement, construction and commissioning has been proposed according to comparison and analysis of practices in domestic & overseas plant project, procedures for progress control in the globally reputed petrochemical client, company rules and recommendation of the expert in progress control.

  • PDF

인체 측정 방법 및 측정 항목에대한 KS와 ISO의 비교 (The comparison of the basic human body measurement definitions and anthropometric terms between KS and ISO)

  • 이영숙;김동진;남경희;안병덕;이관석
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1997년도 춘계학술대회논문집
    • /
    • pp.247-255
    • /
    • 1997
  • In this study, the comparison of the basic human body measurement definitions and anthropometric terms between the Korean Standard and the International Standard. Measurement definitions, measurement method and measurement terms of the international standard ISO 8559, 7250 were compard with the KSRI-88-103-IR. We have tried to suggest the new methods and new terms such as eye height, waist height, arm length.

  • PDF

잡음평형도와 측정회로에 관한 연구 (A Study on the Degree of Line Balance to Noise and its Measurement Circuits)

  • 여상근;김정태
    • 정보통신설비학회논문지
    • /
    • 제9권2호
    • /
    • pp.35-41
    • /
    • 2010
  • The balance coefficients between telecommunication lines are specified in the technical standard and the power induction computation method varies in the order of 100 times in magnitude according to the amount of impedance. The results of actual balance measurements, differing from time to time with the measurement circuit or increasing proportionally as the induction voltage increases, appeared as a measurement error because of not using the standard measurement circuit. This article investigates such errors and proposes the use of a standard balance measurement circuit and a measurement device impedance under the domestic notification standard and the ITU-T international standard.

  • PDF

무선이어폰 재생 시간 측정 방법 및 보고 양식 개발 (Development of Wireless Earphone Playback Time Measurement Method and Report Form)

  • 한문환;정인호
    • 한국산업융합학회 논문집
    • /
    • 제25권2_2호
    • /
    • pp.299-307
    • /
    • 2022
  • Wireless earphones, along with smart devices, are the most sought-after products by consumers. Compared to general earphones, wireless earphones do not have twisted wires and are easy to use, so various types of products are currently on the market. However, information on quality is somewhat lacking, so consumers tend to purchase products according to brand awareness, and manufacturers are delivering information to consumers using different standards for each product because there is no standard for quality control. In particular, the playback time of wireless earphones is a factor that directly affects consumers' purchases, so a standard measurement method is needed to properly measure it. In this paper, we present a method for measuring the audio playback time of wireless earphones derived from domestic wireless earphone status survey, commercial product measurement test, and research analysis, and a developed standard measurement method. In addition, this paper proposes a measurement result reporting format to provide accurate information to consumers and induce a fair competitive environment for each product to manufacturers.

정보통신시설공사 수량산출기준에 관한 연구 (A Study on the Standard Method of Measurement Information Communication Field Contractors)

  • 설동화;이광희
    • 정보통신설비학회논문지
    • /
    • 제2권4호
    • /
    • pp.52-63
    • /
    • 2003
  • This study proposes a change from the currentexpected price integrated system, which is based on the standard of estimated unit manpower and material, to a new actual construction cost integrated system. In order to implement it, the standard method of measurement organization system as well as the communication area standard of estimated unit manpower and material should be changed Moreover, the work breakdown structure and itemized structure should be assorted.

  • PDF

세척공정의 트리클로로에틸렌 TWA 및 STEL 평가 사례 (TCE Exposure Assessment of Cleaning Workers)

  • 김현수
    • 한국산업보건학회지
    • /
    • 제33권1호
    • /
    • pp.3-5
    • /
    • 2023
  • Objective: This study introduces exposure concentrations of time-weighted average standard (TWA) evaluation and short-time exposure standard (STEL) evaluation for trichloroethylene in the cleaning process. Methods: Trichloroethylene measurement was conducted according to the KOSHA Guide (A-24-2019) method. It was carried out twice. Results: As a result of the first measurement, TWA concentration exceeded 4 times the exposure standard and STEL concentration exceeded 16 times, but the inaccuracy and breakthrough of the collection time could not be considered, so the second measurement was conducted. The second measurement result was lower than the first measurement result, but exceeded the exposure standards (TWA, STEL). Conclusions: We were able to confirm that the exposure level of workers in the cleaning process using trichloroethylene exceeded the exposure standard. And it is also considered necessary to grasp the approximate concentration using a detector tube in the preliminary survey.

파이프 프루버의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Pipe Prover)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1388-1398
    • /
    • 2000
  • A pipe prover is a flowmeter calibrator used in flow measurement field. Gravimetric and volumetric methods were applied to determine the basic volume of the pipe prover. Uncertainty of its basic volume measurement was evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainty of determining the basic volume was estimated from the sensitivity coefficient and the standard uncertainty of independent variables. It was found that the uncertainties of the weighing and volume measurements have dominant influence on that of the basic volume determination. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of the basic volume is shown clearly.

Development of Gas Chromatography/Mass Spectrometry for the Determination of Essential Fatty Acids in Food Supplemental Oil Products

  • Ahn, Seonghee;Yim, Yoon-Hyung;Kim, Byungjoo
    • Mass Spectrometry Letters
    • /
    • 제4권4호
    • /
    • pp.75-78
    • /
    • 2013
  • A gas chromatography/mass spectrometric (GC/MS) method was developed as a candidate reference method for the accurate determination of essential fatty acids (linoleic acid, ${\alpha}$- and ${\gamma}$-linolenic acids) in food supplemental oil products. Samples were spiked with three internal standards (stearic acid-$d_{35}$, $^{13}C_{18}$-linoleic acid, and $^{13}C_{18}$-${\alpha}$-linolenic acid). Samples were then subject to saponification, derivatization for methylation, and extraction by organic solvent. For GC/MS measurement, an Agilent HP-88 column, designed for the separation of fatty acid methyl esters, was selected after comparing with other columns as it provided better separation for target analytes. Target analytes and internal standards were detected by selected ion monitoring of molecular ions of their methyl ester forms. The GC/MS method was applied for the measurement of three botanical oils in NIST SRM 3274 (borage oil, evening primrose oil, and flax oil), and measurement results agreed with the certified values. Measurement results for target analytes which have corresponding isotope-labeled analogues as internal standard were calculated based on isotope dilution mass spectrometry (IDMS) approach, and compared with results calculated by using the other two internal standards. Results from the IDMS approach and the typical internal standard approach were in good agreement within their measurement uncertainties. It proves that the developed GC/MS method can provide similar metrological quality with IDMS methods for the measurement of fatty acids in natural oil samples if a proper fatty acid is used as an internal standard.

질량측정에 의한 우량계 표준교정시스템 개발 (Development of Standard Calibration System for the Rain Gauges by Weighting Method)

  • 신강욱;홍성택
    • 제어로봇시스템학회논문지
    • /
    • 제12권8호
    • /
    • pp.818-823
    • /
    • 2006
  • Because the rain gauges of tipping bucket type can easily use the digital signal, the rain gauges are widely used for the meteorological observation. In general, the resolution of rain gauges of tipping bucket type can be categorized by the 0.1mm, 0.5mm, and 1.0mm classes. But, the error of the tipping bucket rain gauges is made by the intensity of rainfalls and is expected to make the standard calibration method for error measurement. Thus, we developed the hardware of standard calibration facility for rain gauges by weighting measurement method and proposed the standard procedure by rainfall intensity in this study Also, we calculated the uncertainty for the rainfall intensity and obtained useful result through the proposed calibration method.