Reliability Analysis of Multi-functional Multi-state Standby System Using Weibull Distribution (와이블 분포를 이용한 다기능 다중상태 대기시스템의 신뢰도 분석)

  • Kim, Ji-Hye;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.3
    • /
    • pp.138-147
    • /
    • 2017
  • As the functions and structure of the system are complicated and elaborated, various types of structures are emerging to increase reliability in order to cope with a system requiring higher reliability. Among these, standby systems with standby components for each major component are mainly used in aircraft or power plants requiring high reliability. In this study, we consider a standby system with a multi-functional standby component in which one standby component simultaneously performs the functions of several major components. The structure of a parallel system with multifunctional standby components can also be seen in real aircraft hydraulic pump systems and is very efficient in terms of weight, space, and cost as compared to a basic standby system. All components of the system have complete operation, complete failure, only two states, and the system has multiple states depending on the state of the component. At this time, the multi-functional standby component is assumed to be in a non-operating standby state (Cold Standby) when the main component fails. In addition, the failure rate of each part follows the Weibull distribution which can be expressed as increasing type, constant type, and decreasing type according to the shape parameter. If the Weibull distribution is used, it can be applied to various environments in a realistic manner compared to the exponential distribution that can be reflected only when the failure rate is constant. In this paper, Markov chain analysis method is applied to evaluate the reliability of multi-functional multi-state standby system. In order to verify the validity of the reliability, a graph was generated by applying arbitrary shape parameters and scale parameter values through Excel. In order to analyze the effect of multi-functional multi-state standby system using Weibull distribution, we compared the reliability based on the most basic parallel system and the standby system.

An availability analysis of switching control system with warm standby fault tolerant architecture (Warm standby 고장김내 구조를 지원하는 교환 제어 시스템에서의 가동률 분석)

  • 송광석;여환근;한창호;문태수;이광배;김현욱;윤충화
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.8
    • /
    • pp.1989-2002
    • /
    • 1996
  • In this paper, we describe several warm standby fault-tolerant models and their operation methods applicable to telephone switching control systems which have dual module structure and need high availability. Unavailabilities of the system implemented by four different methods for each model are computed by using the Markov state model, and then are compared for system performance evaluation. As the results ofsimulations, the warm standby model with triple processors is best in the aspect of data loss, while in most cases the warm standby model with doble processors based on no standby check method provides the highest system avaiability. Periodic changeover increases the system unavailability, but the preriodic standby check on standby module decreases the system unavailability of warm standby model with a single processor and with double processors. On the other hands, the variationas of warm standby model with a single processor and with double processors. On the other hand, the variations of data recovery time and personnel recovery rate have little effect on the system unavailtability.

  • PDF

An Availability Analysis Of Switching Control System with Hot Standby Fault Tolerant Architecture (Hot Standby 고장 감내 구조를 지원하는 교환 제어시스템의 가동률 분석)

  • Song, Gwang-Seok;Yeo, Hwan-Geun;Han, Chang-Ho;Mun, Tae-Su;Yu, Chung-Ryeol;Lee, Gwang-Bae;Kim, Hyeon-Uk;Yun, Chung-Hwa
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.6
    • /
    • pp.985-994
    • /
    • 1995
  • In this paper, we propose two hot standby architectures which not only provide high system availability but also lose little data on fault occurrence. In order to evaluate the performance of the proposed hot standby architectures, the warm standby architecture. In order to evaluate the performance of the propose d hot standby architectures, the warm standby architecture which is made from the hot standby architecture by eliminating its synchronization unit is considered. After system unavailability for each architecture is computed by using the corresponding Markov state diagram, the results are compared and evaluated. As the results, in most cases, hot standby architectures have higher availability than warm standby architecture. Also, hot standby architecture with external synchronization unit always maintains a little higher availability than hot standby architecture with internal synchronization unit. Active set time and personnel recovery rate for each architecture have little effect on system availability. However, in the case that data recovery time is too long, system availabilities of hot standby architectures and warm standby architecture degrade rapidly. In this case, the performance degradation of hot standby architectures is severe, and system availabilities of hot standby architectures eventually become lower than system availability of warm standby architecture.

  • PDF

A Study on the Advanced Reliability Assessment Method about Hot-Standby Sparing System for Railway Signaling (철도신호 대기이중중계구조 제어기의 향상된 신뢰도평가방법에 관한 연구)

  • Min, Geun-Hong;Lee, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1589-1595
    • /
    • 2007
  • This paper suggests the advanced reliability assessment tool for railway signaling Hot-Standby sparing system. Existing reliability assessment for Hot-Standby sparing system controller is done by using single module mean failure rate based on approximated Hot standby sparing system function. Although approximated Hot standby sparing system function can be applied to various Hot standby sparing system, however, it is not able to reflect the exact system structure. In this paper, we suggest the advanced reliability function by identifying changeover-related failure factors and common failure mode which is not considered in existing approximated Hot standby sparing system reliability function via developing Hot standby sparing system model for railway signaling and applying FMECA to this model. Also. we compare reliability assessment results for model system to reliability assessment for existing system.

Cost-effective Power System with an Electronic Double Layer Capacitor for Reducing the Standby Power Consumption of Consumer Electronic Devices

  • Park, Kyung-Hwa;Yi, Kang-Hyun
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.362-368
    • /
    • 2013
  • Commercial home appliances using remotely controlled systems consume electric power while in standby mode to prepare for receiving a remote turn-on signal. The proposed power system can significantly reduce standby power consumption without increasing cost. Furthermore, since a Electronic Double Layer Capacitor (EDLC) is used as an auxiliary power storage element, the life cycle is longer and system reliability can be better than with existing approaches. When the energy of the EDLC is not sufficient for turning on the appliance, the power system charges the EDLC without affecting the main system. The proposed power system is verified with a commercial LCD TV and a 3.93mW standby consumption is obtained. This standby consumption can be regarded as zero standby equipment according to the IEC-62031 standard.

Operation optimization of auxiliary electric boiler system in HTR-PM nuclear power plant

  • Du, Xingxuan;Ma, Xiaolong;Liu, Junfeng;Wu, Shifa;Wang, Pengfei
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2840-2851
    • /
    • 2022
  • Electric boilers (EBs) are the backup steam source for the auxiliary steam system of high-temperature gas-cooled reactor nuclear power plants. When the plant is in normal operations, the EB is always in hot standby status. However, the current hot standby operation strategy has problems of slow response, high power consumption, and long operation time. To solve these problems, this study focuses on the optimization of hot standby operations for the EB system. First, mathematical models of an electrode immersion EB and its accompanying deaerator were established. Then, a control simulation platform of the EB system was developed in MATLAB/Simulink implementing the established mathematical models and corresponding control systems. Finally, two optimization strategies for the EB hot standby operation were proposed, followed by dynamic simulations of the EB system transient from hot standby to normal operations. The results indicate that the proposed optimization strategies can significantly speed up the transient response of the EB system from hot standby to normal operations and reduce the power consumption in hot standby operations, improving the dynamic performance and economy of the system.

A Study of Standby Power Control Based on Zigbee in Smart Home (스마트 홈에서 Zigbee 기반의 대기전력 제어 연구)

  • Lee, S.J.;Kim, D.H.
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.7
    • /
    • pp.879-885
    • /
    • 2014
  • This paper designs and implements the 2 plug type standby power control outlet based on IEEE 802.15.4 using Zigbee and IPv6 network in order to reduce the standby power to the user. The standby power control system is consisted of direct power and standby power plug. Also this system can communicate bidirectionally in wireless because built-in wireless communication modules. One gateway is linked with many standby power control outlet in wireless. Each standby power control outlet executes the operation needed in power control independently. Also each standby power control outlet has its own power can be detected in real time independently of the power can be controlled.

A Study on Increasing the Standby Redundant System Reliability with the Relay of Parallel Structure (병렬구조의 계전기를 갖는 대기중복시스템 신뢰도 향상에 관한 연구)

  • 이규용
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.13 no.22
    • /
    • pp.59-64
    • /
    • 1990
  • This paper is aimed to study the standby redundant system with the relay of parallel structure, by making use of the character of standby system, which reliability is higher than parallel system's if the relay has higher reliability than a certain level. By assigning the low-priced relay to the subsystem, this method increases the relay reliability, optimizes the standby redundant system reliability without violating the restrictions, and consequently reduces the cost.

  • PDF

Reliability Analysis of Multi-State UH-60 Helicopter Hydraulic Pump System with a Multi-Functional Standby Component (다기능 대기부품을 갖는 다중상태 UH-60 헬기 유압펌프시스템의 신뢰도 분석)

  • Kim, Dong-hyeon;Lee, Suk-hoon;Lim, Jae-Hak
    • Journal of Applied Reliability
    • /
    • v.15 no.4
    • /
    • pp.233-240
    • /
    • 2015
  • We analyse reliability of multi-state UH-60 helicopter hydraulic pump system with a multi-functional standby component using Markov analysis method. The system consists of seven components: 2 main pumps, 1 standby pump, 2 primary servos, and 2 tail rotor servos. The standby pump can take over when one more than components fail. Therefore the standby pump is multi-functional standby component. The system has four states: good, deteriorated, dangerous, and failed. The components have 2 states: working and failed. We assume the system is unrepairable when the components fail. We estimate failure distributions and rates using collected failure time data in field. And we classify multi-state of the system according to emergency procedure of UH-60A student handout. We obtain the reliabilities of multi-state system using Visual Basic program because the differential equations is extremely complicated and tedious to solve.

A k-out-of-n System Reliability Optimization Problem with Mixed Redundancy (혼합 중복 k-out-of-n 시스템 신뢰도 최적화 문제)

  • Baek, Seungwon;Jeon, Geonwook
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.39 no.2
    • /
    • pp.90-98
    • /
    • 2013
  • The k-out-of-n system with mixed redundancy is defined as k-out-of-n system which both includes warm-standby and cold-standby components. In case that operating components in the system fail and the system needs quick transition of standby components to operation state, the k-out-of-n system with mixed redundancy is useful for decreasing system failure rate and operational cost. Reliability-Redundancy Optimization Problem (RROP) involves selection of components with multiple choices and redundancy levels for maximizing system reliability with constraints such as cost, weight, etc. A solution methodology by using harmony search algorithm for RROP of the k-out-of-n system with mixed redundancy to maximize system reliability was suggested in this study.