• 제목/요약/키워드: Standing balance symmetry

검색결과 6건 처리시간 0.018초

뇌졸중 환자의 정적, 동적 선자세 균형 대칭성과 보행 기능의 상관관계 연구 (A Study on the Correlation between Static, Dynamic Standing Balance Symmetry and Walking Function in Stroke)

  • 김중휘
    • The Journal of Korean Physical Therapy
    • /
    • 제24권2호
    • /
    • pp.73-81
    • /
    • 2012
  • Purpose: The aim of the present study was to measure the standing balance symmetry of stroke patients using a force-plate with computer system, and to investigate the correlation between the standing balance symmetry and that of the walking function in stroke patients. Methods: 48 patients with stroke (34 men, 14 women, $56.8{\pm}11.72$ years old) participated in this study. Static standing balance was evaluated by the weight distribution on the affected and the nonaffected lower limbs, sway path, sway velocity, and sway frequency, which reflected the characteristic of body sway in quiet standing. Dynamic standing balance was evaluated by anteroposterior and mediolateral sway angle, which revealed the limit of stability during voluntary weight displacement. Symmetry index of static standing balance, (SI-SSB) calculated by the ratio of the affected weight distribution for the nonaffected weight distribution, and symmetric index of dynamic standing balance (SI-SDB) by the ratio of the affected sway angle for the nonaffected sway angle. Functional balance assessed by a Berg balance scale (BBS), and the functional walking by 10m walking velocity, as well as the modified motor assessment scale (mMAS). Results: Static balance scales and SI-SSB was the only correlation with BBS (p<0.05). Dynamic balance scales and SI-DSB, not only was correlated with BBS, but also with 10m walking velocity and mMAS (p<0.01). Additionally, there was a significant difference between SI-SSB and that of SI-DSB (p<0.01). Conclusion: The balance and the walking function relate to real life in the stroke showed strong relationships with the dynamic standing balance symmetry in the frontal plane and the ability of anterior voluntary weight displacement in sagittal plane.

뇌졸중 환자들을 위한 체간 안정화 로봇의 정적인 앉기와 서기 대칭성 평가의 검사-재검사간 신뢰도와 기준 관련 타당도 (The Test-Retest Reliability and Criterion-Related Validity of a Trunk Stability Robot When Measuring Static Sitting and Standing Symmetry in Stroke Patients)

  • 안승헌;김동훈;장영민
    • PNF and Movement
    • /
    • 제16권3호
    • /
    • pp.405-414
    • /
    • 2018
  • Purpose: The purpose of this study was to examine test-retest reliability and criterion-related validity of a trunk stability robot when measuring the weight-bearing symmetry static sitting and standing in stroke patients. Methods: For 27 stroke patients, weight-bearing symmetry was assessed twice, 7 days apart. The intraclass correlation coefficient (ICC2,1) and minimal detectable change (MDC) were used to examine the level of agreement between test and retest. The criterion-related validity of weight -bearing symmetry was demonstrated by Spearman correlation of modified Barthel index (MBI), the sit to stand test (STS), the timed up & go Test (TUG), and the function in sitting test (FIST). Results: the test-retest agreements were excellent for the weight-bearing symmetry of static sitting (ICC2,1: 0.90) and standing (ICC2,1: 0.89). It all showed that the acceptable MDC for the weight-bearing symmetry of static sitting and standing was 0.11 and 0.16, respectively (highest possible score<20 %), indicating that the measures had a small and acceptable degree of measurement error. The weight-bearing symmetry of static sitting was significantly correlated with the TUG(r=-0.45) and FIST(r=0.46)(p<0.05); the weight-bearing symmetry of static standing was also significantly correlated with MBI (r=0.65), TUG (r=-0.67), FIST (r=0.61)(p<0.01), and STS (r=-0.47)(p<0.05). Conclusion: The weight-bearing symmetry of static sitting and standing assessed by the trunk stability robot showed highly sufficient test-retest agreement and mild-to-moderate validity. It could also be useful for clinicians and researchers to evaluate balance performance and monitor functional change in stroke patients.

Clinical Feasibility of Wearable Robot Orthosis on Gait and Balance Ability for Stroke Rehabilitation: A Case Study

  • Shin, Young-Il;Yang, Seong-Hwa;Kim, Jin-Young
    • The Journal of Korean Physical Therapy
    • /
    • 제27권2호
    • /
    • pp.124-127
    • /
    • 2015
  • Purpose: The emphasis on gait rehabilitation after stroke depends on training support through the lower limbs, balance of body mass over the changing base of support. However, muscle weakness, lack of control of lower limb, and poor balance can interfere with training after stroke. For this case study report, a wearable robot orthosis was applied to stroke patients in order to verify its actual applicability on balance and gait ability in the clinical field. Methods: Two stroke patients participated in the training using the wearable robot orthosis. Wearable robot orthosis provides patient-initiated active assistance contraction during training. Training includes weight shift training, standing up and sitting down, ground walking, and stair up and down Training was applied a total of 20 times, five times a week for 4 weeks, for 30 minutes a day. Gait ability was determined by Stance phase symmetry profile, Swing phase symmetry profile, and velocity using the GAITRite system. Balance ability was measured using the Biodex balance system. Results: Subjects 1, 2 showed improved gait and balance ability with mean individual improvement of 72.4% for velocity, 19.4% for stance phase symmetry profile, 9.6% for swing phase symmetry profile, and 13.6% for balance ability. Conclusion: Training utilizing a wearable robot orthosis can be useful for improvement of the gait and balance ability of stroke patients.

경직성 편마비 아동의 둔부 테이핑 적용이 선 자세에서 자세 및 균형에 미치는 영향 (The Effect of Gluteal Taping on Posture and Balance During Standing in Children with Hemiplegic Cerebral Palsy)

  • 서혜정;김중휘;손국경;전제규
    • 대한물리의학회지
    • /
    • 제9권4호
    • /
    • pp.391-398
    • /
    • 2014
  • PURPOSE: The purpose of the present study was to examine the effect of gluteal taping on posture and balance during standing in children with hemiplegic cerebral palsy (CP). METHODS: The subjects of this study were 13 children (six females, seven males; mean aged 8.5) with hemiplegic CP who were gross motor function classification system (GMFCS) level I. The change of posture and balance during standing before and after gluteal taping were measured using inclinometer, gross motor function measure, and functional reaching test. The collected data were analyzed using the paired t-test. RESULTS: The results of this study were as follows : 1) There were statistically significant decrease in the ant. tilt angle of pelvis after gluteal taping in children with hemiplegic CP (p<.05). 2) There were statistically significant increase in functional reaching test after gluteal taping (p<.05). 3) There was no statistically significant difference in gross motor function measure, but significant increase in one leg standing was observed (p<.05). CONCLUSION: As the above results, we suggest that gluteal taping could be effective on improving body alignment and dynamic balance ability during standing in children with hemiplegic CP. Further studies will be required for the short and long term effects of gluteal taping on improving postural symmetry and balance.

Wii Balance Board를 이용한 Sit-to-Stand와 보행기능 측정의 검사-재검사 신뢰도 (Test-retest Reliability of Sit-to-Stand and Gait Assessment Using the Wii Balance Board)

  • 양승례;오유리;전예림;박대성
    • 한국전문물리치료학회지
    • /
    • 제23권3호
    • /
    • pp.40-47
    • /
    • 2016
  • Background: Assessments of Sit-to-Stand (STS) and gait functions are essential procedures in evaluating level of independence for the patients after stroke. In a previous study, we developed the software to analyze center of pressure (COP) in standing position on Wii Balance Board (WBB). Objects: This purpose of this study is to measure test-retest reliability of ground reaction forces, COP and time using WBB on STS and gait in healthy adults. Methods: Fifteen healthy participants performed three trials of STS and gait on WBB. The time (s), vertical peak (%) and COP path-length (cm) were measured on both tasks. Additionally, counter (%), different peak (%), symmetry ratio, COP x-range and COP y-range were analyzed on STS, 1st peak (%), 2nd peak (%) of weight were analyzed on gait. Intra-class correlation coefficient (ICC), standard error measurement (SEM) and smallest real difference (SRD) were analyzed for test-retest reliability. Results: ICC of all variables except COP path-length appeared to .676~.946 on STS, and to .723~.901 on gait. SEM and SRD of all variables excepting COP path-length appeared .227~8.886, .033~24.575 on STS. SEM and SRD excepting COP path-length appeared about .019~3.933, .054~11.879 on gait. Conclusion: WBB is not only cheaper than force plate, but also easier to use clinically. WBB is considered as an adequate equipment for measuring changes of weight bearing during balance, STS and gait test which are normally used for functional assessment in patients with neurological problems and elderly. The further study is needed concurrent validity on neurological patients, elderly patients using force plate and WBB.

경호무도로서 공수도의 미학 (Aesthetics of Karatedo as Security Guard Martial Art)

  • 정일홍
    • 융합보안논문지
    • /
    • 제13권2호
    • /
    • pp.67-73
    • /
    • 2013
  • 본 연구는 경호무도로서 점차 활성화되고 있는 공수도를 미학적으로 탐색해 봄으로서 공수도가 경호무도로서 가지고 있는 미학을 정립하고자 하였다. 연구방법은 문헌연구로 공수도, 미학 관련서적과 자료, 논문을 수집, 참고하였다. 첫째, 공간미이다. 둘째, 시간미이다. 셋째, 통일미이다. 넷째, 대칭미이다. 다섯째, 균형미이다. 여섯째, 조화미이다. 일곱째, 곡선미이다. 여덟째, 리듬미이다. 아홉째, 도덕미이다. 이러한 경호무도로서 공수도의 미학을 연구함으로 내재적 아름다움과 철학, 윤리를 갖춘 경호원과 경호무도로서 발전될 것으로 사료된다.