• Title/Summary/Keyword: Stirrer

Search Result 124, Processing Time 0.035 seconds

Mode-Stirred Reverberation Chamber Characteristic to Stirrer Parameter and Usefulness Evaluation (교반기 매개변수에 따른 교반형 전자파 잔향실의 특성 및 유용성 평가)

  • Kim, Kwang-Yong;Hong, Joo-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1652-1657
    • /
    • 2010
  • This paper analyzes optimal stirrer parameter to improve field uniformity in a mode-stirred reverberation chamber. Stirrer parameter is varied about stirrer height and stirrer angle. Also we analyze quality factor, number of excited modes and stirrer efficiency that affect field uniformity. The results show good performance as higher as stirrer height. Isotropic field distribution is formed at $45^{\circ}$ stirrer angle. When stirrer angle varies, scattering characteristic of incident wave are changed. So electric field distribution in a mode-stirred reverberation chamber is also changed. Therefore, it affect field uniformity. The results expect to help that designs stirrer for get better field uniformity. Immunity test performed designed mode-stirred reverberation chamber for semiconductor that categorized by technology. Test result shows that good recurrence compared wave-guide immunity test.

A Study on Mixing Enhancement by Rotating and Oscillating Stirrers in the Micro Channel (미소채널 내 회전교반기와 진동교반기에 의한 혼합향상의 연구)

  • An Sang-Joon;Kim Yong-Dae;Maeng Joo-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.5 s.248
    • /
    • pp.430-437
    • /
    • 2006
  • The mixing effect is studied by comparing rotating and oscillating stirrers in the micro channel. The cases of Re=10 to 80 with various stirring speeds are considered to analysis the effect of Re and stirrer speed for the mixing. Under Re=20, the oscillating stirrer represents better mixing rate than the rotating stirrer up to the critical stirrer speed which has a maximum efficiency. Over Re=30, the results of oscillating and rotating stirrer show that the faster the stirrer speed, the higher the mixing effect within the concerned stirrer speed range and the oscillating stirrer keeps the higher mixing rate. It was found that the mixing effect is a function which has an optimum of the Reynolds number and the stirrer speed. The D2Q9 Lattice Boltzmann Method is used due to the merits of calculation for the unsteady flow with moving boundary.

Numerical Study for Mixing Characteristics of an Oscillating Micro-stirrer (미소진동교반기의 혼합특성에 대한 수치적 연구)

  • Kim, Yong-Dae;Maeng, Joo-Sung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.309-312
    • /
    • 2006
  • Effective mixing is an important problem in microfluidics for chemical and biomechanical applications. In this study, the influences of the Reynolds number and the oscillating frequency on mixing characteristics of micro-stirrer are studied in a microchannel with single stirrer. The influence of fluid inertial effects in an active mixer is first discussed. It is found that the stirring effects by stirrer oscillation are promptly attenuated at low Reynolds number, which makes greatly difficult the rapid mixing. As the inertial effects are increased, the chaotic advection is generated and then developed. The mixing phase is finally developed some mushroom shaped structure. And the mixing efficiency is also studied as a function of the oscillating frequency. We found that the mixing efficiency does not always increase with higher oscillating frequency of stirrer. Consequently, we found the functional relation between the optimal frequency of a stirrer and the Reynolds number.

  • PDF

Studies on Grain Size Refinement for Rheocasting of Hypereutectic Al-18% Si by Using Sieve Type Mechanical Stirrer (과공정 Al-18% Si 합금의 레올로지 성형시 기계적 교반을 이용한 입자 미세화 연구)

  • 강용기;박진욱;강성수;강충길;문영훈
    • Transactions of Materials Processing
    • /
    • v.9 no.4
    • /
    • pp.389-394
    • /
    • 2000
  • The studies on gram size refinement for rheocast processing of hypereutectic Al-18%Si alloys have been investigated in the present study. To increase the efficiency of mechanical stirring, sieve type stirrer are newly designed and implemented for rheocasting of hypereutectic Al-18%Si alloy. Mechanical stirring of semi-solid slurry by using sieve type mechanical stirrer results in morphological changes of the primary Si particles, from angular rod shape to near spherical shape and uniform distribution of proeutectic Si. The remarkable spheroidization of Primary Si Particles and distributional uniformity of proeutectic Si show well the efficiency of sieve type mechanical stirring method which can accelerate the coalescence-fracture-wear of the individual particles by strong turbulent flow between lattices during rotation of sieve type stirrer.

  • PDF

Friction Stir Welding Tool Geometries Affecting Tensile Strength of AA6063-T1 Aluminum Alloy Butt Joint

  • Kimapong, Kittipong;Kaewwichit, Jesada;Roybang, Waraporn;Poonnayom, Pramote;Chantasri, Sakchai
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.145-153
    • /
    • 2015
  • Friction Stir Welding (FSW) is a solid state welding that could successfully weld the difficult-to-weldmaterials such as an aluminum alloy. In this welding process, the stirrer of the welding tool is one of the important factors for producing the perfect sound joint that indicates the higher joint strength. So, this report aims to apply the friction stir welding using various stirrer geometries to weld the AA6063-T1 aluminum alloy butt joint, investigates the mechanical properties of the joint and then compares the mechanical properties with the microstructure of the joint. An experiment was started by applying the friction stir welding process to weld a 6.3 mm thickness of AA6063-T1 aluminum alloy butt joint. A study of the stirrer geometries effect such as a cylindrical geometry, a cone geometry, a left screw geometry and a right screw geometry at a rotational speed of 2000 rpm and a welding speed of 50-200 mm/min was performed. The mechanical properties such as a tensile strength and a hardness of the joint were also investigated and compared with the microstructure of the joint. The results are as follows. A variation of FSW Stirrer shape directly affected the quality AA6063-T1 aluminum alloy butt joint. A cylindrical stirrer shape and a cone stirrer shape produced the void defect at the bottom part of the weld metal and initiated the failure of the joint when the joint was subjected to the load during the tensile test. Left and right screw stirrer shapes gave the sound joint with no void defect in the weld metal and affected to increase the joint strength that was higher than that of the aluminum base metal.

Shape Optimization of an Active Micro-Mixer for Improving Mixing Efficiency (혼합 효율 향상을 위한 마이크로 동적 믹서의 형상최적화)

  • Park, Jae-Yong;Kim, Sang-Rak;Lee, Won-Gu;Yoo, Jin-Sik;Kim, Young-Dae;Maeng, Joo-Seung;Han, Seog-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.146-152
    • /
    • 2007
  • An active micro-mixer, which was composed of an oscillating micro-stirrer in the microchannel to provide rapid, effective mixing at high flow, rates was analyzed. The effects of molecular diffusion and disturbance by the stirrer were considered with regard to two types of mixer models: the simple straight microchannel and microchannel with an oscillating stirrer. Two types of mixer models were studied by analyzing mixing behaviors such as their interaction after the stirrer. The mixing was calculated by Lattice Boltzmann methods using the D2Q9 model. In this study, the time-averaged mixing index formula was used to estimate the mixing performance of time-dependent flow. The mixing indices of the two models compared. From the results, it was found that the mixer with an oscillating stirrer was much more enhanced and stabilized. Therefore, an optimum design for a dynamic micro-mixer with an oscillating stirrer was performed using Taguchi method in order to obtain a robust solution. The design parameters were established as the frequency, the length and the angle of the stirrer and the optimal values were determined to be 2, 0.8D and ${\pm}75^{\circ}$, respectively. It was found that the mixing index of the optimal design increased 80.72% compared with that of the original design.

Approximate Optimization of an Active Micro-Mixer (능동형 미소혼합기의 근사최적화)

  • Park, Jae-Yong;Kim, Sang-Rak;Yoo, Jin-Sik;Lim, Min-Gyu;Kim, Young-Dae;Han, Seog-Young;Maeng, Joo-Seung
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.5
    • /
    • pp.95-100
    • /
    • 2008
  • An active micro-mixer, which is composed of an oscillating micro-stirrer in the micro-channel to provide effective mixing was optimized. The effects of molecular diffusion and disturbance by the stirrer were considered with regard to two types of mixer models: the simple straight micro-channel and micro-channel with an oscillating stirrer. Two types of mixer models were studied by analyzing mixing behaviors such as their interaction after the stirrer. The mixing was calculated by Lattice Boltzmann methods using the D2Q9 model. In this study, the time-averaged mixing index formula was used to estimate the mixing performance of time-dependent flow. The mixing indices of the two models were compared. From the results, it was found that the mixer with an oscillating stirrer was much more enhanced and stabilized. Therefore, an approximate optimization of an active micro-mixer with an oscillating stirrer was performed using Kriging method with OLHD(Optimal Latin Hypercube Design) in order to determine the optimal design variables. The design parameters were established as the frequency, the length and the angle of the stirrer. The optimal values were obtained as 1.0346, 0.66D and $\pm45^{\circ}$, respectively. It was found that the mixing index of the optimal design increased by 88.72% compared with that of the original design.

The Effect of Karman Vortex for Mixing in a Micro-channel with an Oscillating Micro-stirrer (진동 교반기가 있는 미소채널에서 혼합에 대한 Karman 와의 영향)

  • An, Sang-Joon;Maeng, Joo-Sung;Kim, Yong-Dae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.144-152
    • /
    • 2006
  • In order to consider the effect of Karman vortex for mixing, mixing indices are calculated for 4 models of micro channel flows driven from the combinations of a circular cylinder and a oscillating stirrer. And their results are compared to that of a simple straight micro channel flow(model I). The mixing rate is improved 5.5 times by Karman vortex (model II) and 11.0 times by the stirrer(model III) respectively. In case of successive mixing by the cylinder and the stirrer(model IV), $27\%$ of shortening the channel length for the complete mixing as well as 1.37 times improvement of mixing efficiency then model III. And then, variation of mixing indices are much stable comparing with the others. Thus, it is found that the Karman vortex plays a good role as a pre-mixing method. The D2Q9 Lattice Boltzmann methods are used.

Improvement Scheme of Field Uniformity of Stirrer Parameter in Reverberation Chamber (전자파 잔향실의 교반기 매개변수에 따른 전계 균일도 향상 방안)

  • Kim, Kwang-Yong;Hong, Joo-Il;Han, Seung-Moon;Doo, Jin-Suk;Huh, Chang-Su;Lee, Ki-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1583_1584
    • /
    • 2009
  • Reverberation chamber have become a common tool in radiated susceptibility and emission testing of electronic equipment. In a reverberation chamber, internal electromagnetic fields are mixed by metallic stirrer. Due to elimination of Polarization characteristic in reverberation chamber, electromagnetic wave reached to EUT all aspect angle. Hence, Field distribution in overmode reverberation chamber can be presented by chi-square distribution. Field uniformity in reverberation chamber have to satisfy standard deviation below 3dB and is influenced by mechanical stirrer. This paper investigates relationship between change of stirrer parameter and field uniformity in reverberation chamber.