• Title/Summary/Keyword: Stray light analysis

Search Result 22, Processing Time 0.025 seconds

In-orbit Stray light Performance Simulation for Geostationary Ocean Color Imagers

  • Jeong, Yu-Kyeong;Jeong, Soo-Min;Ryu, Dong-Ok;Kim, Sug-Whan;Hong, Jin-Suk;Youn, Heong-Sik;Woo, Sun-Hee;Kim, Seong-Hui
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.49.4-50
    • /
    • 2009
  • We report stray light modeling and analysis results for the current and proposed next generation ocean color imagers with Sun and the target area around Korean penninsular as viewed from geostationary orbit. The imagers used in this study are GOCI of 140mm in diameter and a proposed next generation GOCI (GOCI-II) of about 300mm in diameter. First, we built complete GOCI and GOCI-II 3D optical system models with the realistic surface characteristics. These optical models were incorporated into the in-house built Intergrated Ray Tracing (IRT) algorithm, connecting the Sun, the measurement target area and the instruments via single ray tracing computation for radiative transfer and scattering. The stray light level was then estimated for possible orbital configurations for science measurement and in-orbit calibration operation. The simulation details, results and their implications are presented.

  • PDF

Comparison Analysis of Field Test Methods Based on Technical Criteria of Electrolytic Corrosion Protection in Urban Railway (도시철도 전식방지 기술기준에 따른 시험방법 비교분석)

  • Kim, Jae-Moon;Jung, Ho-Sung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1885-1891
    • /
    • 2010
  • Recently metropolitan local governments is actively introducing urban railway's expand and light rail transit as a means of new transport system. DC electricity feeder system operating in the domestic urban railway is typically a feedback circuit consisted of the contact wire and electric railway vehicle via rail. But stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit with respect to a given structure. Stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. At the place where the current leaves the rail and metallic structures, electrolytic corrosion may take place. This paper presents comparison analysis of field test methods based on criteria of electrolytic corrosion protection of buried metallic structures adjacent to DC traction systems.

  • PDF

NEW DEVELOPED PORTABLE NEAR INFRARED (NIR) SYSTEM USING MICROSPECTROMETER

  • Woo, Young-Ah;Ha, Tae-Kyu;Kim, Jae-Min;Kim, Hyo-Jin
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1123-1123
    • /
    • 2001
  • In recent years, a miniature spectrometer has been extensively developed due to the marriage of fiber optics and semiconductor detector array. This type of miniature spectrometer has advantages of low price and robustness due to the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. These systems are ideal for use in teaching labs, process monitoring and field analyses. A portable near infrared (NIR) system has been developed for qualitative and quantitative analysis. This system includes a tungsten halogen lamp for light source, a fiber optics connected a light source, and a sample module to the microspectrometer, The size of spectrometer can be as small as 2.5 cm x 1.5 cm x 0.1 cm. Wavelength ranges can be chosen as 360-800 nm, 800-1100 nm and 1100-1900 nm depending on the type of detector. The software consists of various tools for multivariate analysis and pattern recognition techniques. To evaluate the system, long and short-term stability, wavelength accuracy, and stray light have been investigated and compared with conventional scanning type NIR spectrometer. This developed system can be sufficiently used for quantitative and qualitative analysis for various samples such as agricultural product, herbal medicine, food, petroleum, and pharmaceuticals, etc.

  • PDF

Optical Analysis for the Estimation of Whole Blood Coagulation Time with Magnetic Particles (자성 철 가루를 이용한 혈액 응고시간 측정법의 광학적 해석)

  • Lee, Jaehyun;Choi, Hyoungsoon;Jang, Dongwoo;Nahm, Kie B.
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.6
    • /
    • pp.338-341
    • /
    • 2013
  • Prothrombin Time (PT) is used as a measure of blood coagulation time. An optical analysis of the signal generating mechanism is described here for the reflection-type arrangement. Thromboplastin added into serum or whole blood initiates the coagulation process. We added a sufficient amount of magnetic particles into the sample before adding thromboplastin and subjected the mixture to a rotating magnetic field. The laser light gets reflected in a periodically modulated fashion with respect to the magnetic field rotation. Analysis of this decaying modulation could produce a reasonable coagulation time. We also introduce a simulation model to explain the signal generating mechanism using LightTools.$^{TM}$

Mirrors and Optomechanical Structures Design and Analysis for Linear Astigma-tism Free Three Mirror System (LAF-TMS)

  • Park, Woojin;Hammar, Arvid;Lee, Sunwoo;Chang, Seunghyuk;Kim, Sanghyuk;Jeong, Byeongjoon;Kim, Geon Hee;Kim, Daewook;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.55.4-56
    • /
    • 2018
  • Linear Astigmatism Free - Three Mirror System (LAF-TMS) is the linear astigmatism free off-axis wide field telescope with D = 150 mm, F/3.3, and $FOV=5.51^{\circ}{\times}4.13^{\circ}$. We report the design and analysis results of its mirrors and optomechanical structures. Tolerance allowance has been analyzed to the minimum mechanical tolerance of ${\pm}0.05mm$ that is reasonable tolerance for fabrication and optical alignment. The aluminum mirrors are designed with mounting flexure features for the strain-free mounting. From Finite Element Analysis (FEA) results of mounting torque and self-weight, we expect 33 - 80 nm RMS mirror surface deformations. Shims and the L-bracket are mounted between mirrors and the mirror mount for optical alignment. The mirror mount is designed with four light-weighted mechanical parts. It can stably and accurately fix mirrors, and it also suppresses some of stray light.

  • PDF

Reliability Assessment against Ultimate Bending Moment of Ships′ Hull Girder (선체의 최종굽힘 모멘트에 대한 신뢰성 검토)

  • Joo-Sung Lee;P.D.C. Yang
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.1
    • /
    • pp.103-112
    • /
    • 1992
  • The ultimate bending moment of ships is one of the principle strength considered in ship design. Several methods have been proposed to predict the ultimate bending moment and its major part is, in general, predicting the ultimate compressive strength of stiffened panels. In this paper, made is the review on the methods and formulae of predicting the ultimate compressive strength and they are applied to predicting the ultimate bending moment. Safely levels of three bulk carriers have been derived evaluated for two loading conditions, stray, light ship condition and full load condition, and wave bending by Classification Society Rule(ABS, DnV and Lloyd Rule). The present reliability analysis problem is strictly non-linear and the Advanced First-Order Reliability Method has been used. From the results of parametric studies, the methods of predicting the ultimate compressive strength of stiffened panels are compared from the view point of their applicability to the reliability assessment of ships structures. The paper ends wish a brief discussion drawn from the parametric studies and the extension of the study is described.

  • PDF

Radiative transfer analysis for Amon-Ra instrument

  • Seong, Se-Hyun;Ryu, Dong-Ok;Lee, Jae-Min;Hong, Jin-Suk;Kim, Seong-Hui;Yoon, Jee-Yeon;Park, Won-Hyun;Lee, Han-Shin;Park, Jong-Soo;Yu, Ji-Woong;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.28.4-29
    • /
    • 2009
  • The 'Amon-Ra' instrument of the proposed 'EARTHSHINE' satellite is a dual (i.e. imaging and energy) channel instrument for monitoring the total solar irradiance (TSI) and the Earth's irradiance at around the L1 halo orbit. Earlier studies for this instrument include, but not limited to, design and construction of breadboard Amon-Ra imaging channel, stray light suppression and system performance computation using Integrated Ray Tracing (IRT) technique. The Amon-Ra instrument is required to produce 0.3% in uncertainty for both Sunlight and Earthlight measurement. In this study, we report accurate estimation of the output electric signal derived from the orbital variation of radiant exitance from the Sun and the Earth arriving at the aperture and detector plane of the Amon-Ra. For this, orbital irradiance are computed analytically first and then confirmed by simulation using Integrated Ray Tracing (IRT) model. Specially, the results show the arriving power at the bolometer detector surface is $1.24{\mu}W$ for the Sunlight and $1.28{\mu}W$ for the Earthlight, producing the output signal pulses of 34.31 mV and 35.47 mV respectively. These results demonstrate successfully that the arriving radiative power is well within the bolometer detector dynamic range and, therefore, the proposed detector can be used for the in-orbit measurement sequence. We discuss the computational details and implications as well as the simulation results.

  • PDF