• Title/Summary/Keyword: Strengh ratio

Search Result 12, Processing Time 0.026 seconds

An Experimental Study on the Strengh and Ductility of High-Strength Flexural Members (고강도 휨재의 강도와 연성에 관한 실험적 연구)

  • Lee, Seung-Joon
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.1
    • /
    • pp.19-28
    • /
    • 2001
  • The strength and ductility of steel flexural members are investigated experimentally in this study. As for the performance evaluation of flexural members. experimental studies on the 9 test specimens were carried out. Four specimens were fabricated from SM490 and five specimens were fabricated from SM570. The experimental results of the specimens were analyzed with focus on the flexural strength and ductility. The experimental results exhibited that all the specimens provided sufficient flexural strengthes which exceeded the nominal flexural strengthes specified in the current Limit State Design Specification by average ratio of 1.22. However. the experimental results showed that the compact-section specimens fabricated from SM570 did not provide the required rotational ductility. The yield-to-tensile strength ratio(YR) of SM570 of about 0.9 might be the causes of such insufficient capacities.

  • PDF

Behavior of Plain and Steel Fiber Reinforced High Strengh Concrete Under Uniaxial and Biaxial Compression (1축 및 2축 압축을 받는 고강도콘크리트 및 강섬유보강 고강도콘크리트의 거동)

  • Lim, Dong-Hwan;Park, Sung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.5-8
    • /
    • 2005
  • The purpose of this study is to investigate the mechanical characteristics of plain and steel fiber high strength concrete under uniaxial and biaxial loading condition. A number of plain and steel fiber high strength concrete cubes having 28 days compressive strength of 82.7Mpa (12,000psi) were made and tested. Four principal compression stress ratios, and four fiber concentrations were selected as major test variables. From test results, it is shown that confinement stress in minor stress direction has pronounced effect on the strength and deformational behavior. Both of the stiffness and ultimate strength of the plain and fiber high strength concrete increased. The maximum increase of ultimate strength occurred at biaxial stress ratio of 0.5 in the plain high strength concrete and the value were recorded 30 percent over than the strength under uniaxial condition. The failure modes of plain high strength concrete under uniaxial compression were shown as splitting type of failure but steel fiber concrete specimens under biaxial condition showed shear type failure.

  • PDF

An Experimental Study on the Engineering Properties and B.P Test of Ready Mixed Concrete Using EEZ Sand and Crush Sand (부순모래와 EEZ모래를 혼합사용한 레미콘의 B.P실험 및 공학적 특성에 관한 연구)

  • Shin, Seung-Bong;Kim, Young-Sun;Kim, Young-Duck;Lee, Sung-Yon;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.105-108
    • /
    • 2006
  • Recently, trouble of sand supplying is occurred according to exhaustion of natural sand resources. Therefore various measures are proposed for solution of trouble of sand supply and crushed sand among measures is used as one of most universal measures. But because crushed sand have poor particle shape and plenty of mikes micro particle, the quality of concrete using crushed sand deteriorated. Therefore, this study evaluated engineering property of concrete with replacement ratio of crushed sand and EEZ sand applied evaluation result to fundamental data for quality control of concrete using crushed sand and EEZ sand and The result of this study have shown that quality of concrete using crushed sand and EEZ sand and The compressive strengh of concrete up to 50, 70% EEZ sand replacement by crush sand, nearly equal to that of general sand.

  • PDF

Effect of the Coarse Aggregate Volume by High Temperature Mechanical Properties of Ultra High Strength Concrete (굵은골재의 용적이 초고강도 콘크리트의 고온역학적특성에 미치는 영향)

  • Hwang, Eui-Chul;Kim, Gyu-Yong;Choe, Gyeong-Cheol;Yoon, Min-Ho;Lee, Bo-Kyeong;Kim, Jung-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.67-68
    • /
    • 2015
  • Recently, usage of ultra-high strengh concrete(UHSC) have been increased. Concrete has been recognized as a material which is resistant to high temperatures, but chemicophysical property of concrete is changed by the high temperature. So, mechanical properties of concrete may be reduced. Therefore, this study evaluated effect of the coarse Aggregate volume by high temperature mechanical properties of UHSC. Residual mechanical properties are evaluated under fine aggregate ratio 40,60% and 500℃ temperature on UHSC of W/B 15, 20%. As result, residual mechanical properties of UHSC are high by lower coarse aggregate volume.

  • PDF

P-M Relations of Slender Welded Built-up Square CFT Column under Eccentric Loads (시공성을 향상시킨 용접조립 각형 CFT 편심 장주의 P-M 관계)

  • Lee, Seong-Hui;Choi, Sung-Mo;Kim, Young-Ho
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.23-31
    • /
    • 2015
  • CFST columns are structurally superior because the concrete inside the steel tubes prevents local buckling at the tubes and the tubes confine the concrete. And, the thickness of steel tube in CFST column has been thinner with development of high-strengh steel. The thinner the steel tube of a square CFST column is, the more local buckling is likely to occur. For this reason, we developed welded built-up square steel tube with stiffeners which are placed at the center of the tube width acts as an anchor. In this study, we conduct experimental test for three specimens of the 4m long span welded built-up square CFT column with parameters of L/D and D/t. And, the test results were compared with the analysis results by M-${\phi}$-P Program.

Evaluation and Test of Slenderness Ratio Effect on Buckling Characteristics of Thin Cylindrical Structures Subjecting the Shear Loads (전단하중을 받는 얇은 원통구조물의 세장비에 따른 좌굴특성 평가 및 시험)

  • 구경회;김종범;이재한
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.3
    • /
    • pp.535-543
    • /
    • 2002
  • The purpose of this paper is to investigate the slenderness ratio effect on buckling characteristics of thin cylindrical structures subjecting the shear loads in detail. To do this, the buckling strength evaluations were carried out with using the evaluation formulae proposed by J. Okada. From the results of the buckling strength evaluations, the three types of staled cylindrical test specimen, which have L/R=3.1, 1.6, and 1.0, are determined for the numerical analyses and tests. From results, target slenderness ratio over L/R=3 results in dominant bending buckling mode, smaller slenderness ratio under L/R=1 results in dominant shear buckling mode, and near L/R=1.6 region shows the mixed buckling mode which has the bending and shear buckling mode simultaneously. Most results of buckling characteristics obtained by the numerical analyses and the evaluation formulae we in good agreement with those of tests.

A Study on Physical Properties of Concrete using Admixtures for High Strength Concrete (고강도콘크리트용 혼화재를 사용한 콘크리트의 물성에 관한 연구)

  • 이승한
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.2
    • /
    • pp.155-164
    • /
    • 1995
  • This study was performed to get high strength of the precase concrete adopting a steam curing by using a gypsum-admixture for the high strength concrete. The superplasticizer was used to compensate low slump of base concrete keeping its slump up about $6{\pm}1cm$. To examine the property for strength revelation of concrete using admixtures for a high strength concrete, steam and standard curing were compared each other. Test results were shown that admixtures for high strength concrete were more effective in steam curing than standard curing. On the condition that the unit cement content is about $530{\sim}600kg/m^3$, the compressive strength of concrete replacing by 10% of the admixture was obtained over $65Okgf/cm^2$, which was increased as 1.3 times as that for the nonreplacement. When the admixture was replaced to 15-30%, the compressive strengh was obtained over $700kgf/cm^2$ which was increased as 1.4 - 1.5 times. Therefore, the admixture for high strength concrete, being effective in steam curing, was more efficient to get a high strength concrete using only steam curing instead of an autoclave curing for the secondary products of cement.

Structural Behaviour of TEC-BEAM Connection with Steel Column Under Cyclic Loading (반복하중을 받는 TEC-BEAM 철골브라켓 접합부 거동평가)

  • Ju, Young Kyu;Kim, Ji Young;Kim, Myeong Han;Jung, Kwang Ryang;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.1
    • /
    • pp.51-58
    • /
    • 2002
  • To reduce the story height for high-rise buildings, the TEC Beam is developed as a new composite beam composed of structural tee, precast concrete, stirrup, and site-in-cast reinforced concrete slab. The preliminary test of the proposed system was performed for simple beams and it showed a good behavior. However, for the field application of the system, it is required to develope a steel moment resisting connection using steel brackets on which upper rebars of the TEC BEAM are anchored. In this paper, three types of the proposed system are experimentally investigated. The parameters of the test are as follows: (1) the spacing of transverse bars, (2) the ratio of width of rebar's layer to bracket length. Specimens were classified as semi-rigid full strength by the Eurocode 4. It could be concluded that the proposed moment resisting system shows a good structural behavior and may be applicable in the filed.

Electrical properties of $C_{22}$-Quinolium(TCNQ) LB films depending on a type of applied voltage and temperature (인가 전압 형태 및 온도에 따른 $C_{22}$-Quinolium(TCNQ) LB막의 전기적 특성)

  • Song, Il-Seok;Yoo, Deok-Son;Kim, Young-Kwan;Kim, Tae-Wan;Kang, Dou-Yol
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1193-1196
    • /
    • 1993
  • Electrical properties of $C_{22}$-Quinolium(TCNQ) Langmuir-Blodgett(LB) films are reported depending on a type of applied voltage on a type of applied voltage and temperature. A conductivity was identified to be anisotropic with a ratio of ${\sigma}||/{\sigma}{\bot}{\simeq}10^7$ at room temperature. The I-V characteristics along the film surface direction show an ohmic behavior up to a few hundred volts. But the I-V characteristics in the vertical direction display an ohmic behavior for low-electric field, and a nonohmic behavior for high-electric field. This nonohmic behavior has already been interpreted as a conduction mechanism of space-charge limited current and Schottky effect near the electric-field strengh of $10^6$ V/cm. When the electric field exceeds further, there is anormalous phenomia similiar to breakdown. From the study of I-V characteristics with the application of step or pulse voltage, we have found that the breakdown voltage shifts to higher one as the step or pulse interval becomes shorter. These results indicate that the breakdown is due to both electrical and thermal effect. To see the infulence of temperature, current was measured as function of temperature with several bias voltages, which are lower than that of breakdown. It shows that the current increases about 3 orders of magnitude near $60{\sim}70^{circ}C$, and remains constant for a while up to $140^{\circ}C$ and then suddenly drops. Arahidic acid was used to cmpare with $C_{22}$-Quinolium(TCNQ) LB films.

  • PDF

A Case-Control Study on the Risk Factors of the Low Birth Weight (저체중아(低體重兒) 출산 관련요인에 관한 사례-비교군 연구)

  • Meng, Kwang-Ho;Lee, Sang-Yoon;Lee, Hae-Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.251-257
    • /
    • 1984
  • Low birth weight baby, defined as the baby born with less than or equal to 2,500g of body weight by WHO has been a great concern in the fold of maternal and child health since the low birth weight is a major cause of high perinatal mortality. Any measure to prevent the low birth weight baby is most desirable not only for saving the life of a baby but also for levelling up the health of the whole society. The authors attempted to figure out how some known maternal risk factors are related to the low birth weight and to measure their strengh of associations in terms of relative risk using hospital birth records. For this study, hospital birth records of 66 low birth weight cases and sex-parity matched 198 normal controls were chosen from Kangnam St. Mary's Hospital, Catholic Medical Center, and the data were analyzed in regards to several maternal factors. The risk factors studied were mother's age, mother's ABO blood type, previous histories of abortion, low birth weight baby, fetal wastage, and maternal diseases represented by anemia, hypertension, proteinuria, and glucosuria. The results obtained in this study were as follows: 1. The mean body weight of the cases and controls were 1,955g and 3,251g, respectively, and the heights were 41cm for cases and 50cm for controls. Mean gestation periods of cases and controls were 34 weeks and 39 weeks, respectively. 2. Young mother(less than or equal to 20 years of age) or old mother(more than or equal to 30 years of age) experienced more frequently the delivery of low birth weight babies than mothers in between 21 and 29 years of age. But the difference was not statistically significant. 3. Mothers whose blood type was O tended to have slighty higher frequency of low birth weight babies while B mothers have lower frequency. But the difference was not statistically significant too. 4. Those mothers who had experienced low birth weight baby in the past tended to give more births of low birth weight babies. This factor is even statistically significant and the relative risk of the prior experience of low birth weight was 6.7. 5. Mothers with experience of fetal losses and mothers of more than two pregnancies had higher frequency of low birth weight than the mothers with no fatal losses and of first pregnancy, but the difference was not statistically significant. 6. Statistically significant higher frequency of low birth weight were found in mothers with hypertension(odds ratio=4.07), anemia(odds ratio=22,33), and proteinuria(odds ratio=2.79). In summary, these study results strongly suggest that in order to prevent the low birth weight, special care should be made when the mother is too young or too old, and when the mother has experienced deliveries of low birth weight and fetal deaths. Medical control for the maternal diseases such as anemia and hypertension is also needed before or during the pregnency.

  • PDF