• Title/Summary/Keyword: Stress relief cone

Search Result 11, Processing Time 0.038 seconds

A Study on the Optimization of Interfacial Pressure for the Stress Relief Cone in the Ultra-High Voltage Level Prefabricated Type Joint Box (초초고압 CV Cable용(用) 조립형 직선 접속함에서의 Stress Relief Cone 계면압력 최적화에 관한 연구)

  • Baek, J.H.;Baek, S.Y.;Lee, S.K.;Huh, G.D.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1614-1616
    • /
    • 1998
  • Insulation performance of major components of prefabricated joint such as epoxy insulation unit and premolded rubber cone are guaranteed by material selection design and proper manufacturing. On the other hand insulation performance of the interfaces between the premolded rubber cone and the epoxy insulation unit and the cable insulation is maintained by keeping the premolded rubber cone to close contact with such insulation by spring. Electric characteristics of a interface depend on the contact pressure, but the required characteristics are assured so far as a proper contact pressure is maintained. In this report, the interfacial pressure by pressure sensors both in the early stage and after heating cycle were measured and the simulation by FEM program were presented. The comparison of these two results show that interfacial pressure could be controlled optimally by changing the spring length and lubricant state of the interface.

  • PDF

A INSULATING DESIGN OF $SF_6$ GAS SEALING END OF CONDENSER CONE TYPE USED FOR 345KV OF CABLE (콘덴서 콘 방식의 345KV OF 케이블용 $SF_6$ 가스중 종단접속함의 절연 설계)

  • Kim, H.J.;Lee, S.C.;Oh, O.J.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1553-1555
    • /
    • 1994
  • In this paper, we describes the research in condenser cone of $SF_6$ gas sealing end for 345KV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory ana FEM. As a results. we have been designed the condenser cone and the inner insulation part of $SF_6$ seating end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone.

  • PDF

The Analysis of Characteristics of Silicone Rubber in Insulating Oil (절연유에 의한 Silicone Rubber의 특성 변화 분석)

  • Kim, H.J.;Kim, H.J.;Lee, C.M.;Han, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1216-1217
    • /
    • 2008
  • A description is given of impregnated silicone rubber used in accessories for application on outdoor termination (EB-A). We examines the effects of swelling and mechanical/electrical characteristics for impregnated silicone rubber to develop slip on type sleeve of silicone material. There are semi-conductive silicone rubber and insulation silicone rubber. This examination is monitored as a function of the viscosity and temperature of oil during 30hr. We measure elongation at breakdown and AC breakdown strength and volume resistivities of the oil-impregnated silicone rubbers. The measured values are compared to initial value as function of stress relief cone.

  • PDF

Analysis on Thermo-Mechanical Characteristics of Underground Cable Termination (지중송전케이블 종단접속함 Thermo-Mechanical 특성 분석)

  • Jung, Chae-Kyun;Kang, Ji-Won;Park, Hung-Sok;Kim, Du-Jin;Roh, Tae-Hyueng;Yoon, Jong-Keon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.365-366
    • /
    • 2015
  • This paper describes the analysis on thermo-mechanical characteristics of underground cable termination. Specially, the interface pressures between stress relief cone and XLPE insulation were analysed according to the change of conductor temperature and ambient temperature. This interface pressures were measured by real test with current transformer and chamber and the interface pressure was changed with conductor and ambient temperature. This paper will continue to perform the test with various cases, then the relation between low interface pressure and breakdown will prove with test results in the near future.

  • PDF

A Study on the measurement of Interfacial Pressure for the Stress Relief Cone in the High Voltage Level Prefabricated Type Joint Box (초고압용 종단접속함 스트레스 콘의 계면압 측정 연구)

  • Kim, Ki-Sang;Hong, Dong-Suk;Jung, Chae-Kyun;Jang, Tae-In;Kang, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.445-446
    • /
    • 2015
  • 본 논문은 지중송전 케이블 접속함의 이종 절연물에 대한 계면압력 측정에 대하여 기술하였다. 일반적으로 지중 송전케이블의 접속함의 경우, 운전 및 외부조건에 따라 절연물간의 계면압력은 변화하게 되고, 특히 저온에서 계면의 절연성능이 저하되면 고장발생 가능성이 높아진다. 이러한 계면압력 변화 경향을 파악하기 위하여 본 논문에서는 유압 시험을 통해 접속함 조립 시의 초기 계면압력을 측정하였고 그 결과를 기술하였다. 또한 응력 시뮬레이션과 유압 측정값을 비교하여 이론 및 실측값에 대한 신뢰성을 확보하였다.

  • PDF

A Study on the Insulation Design of Normal Joint in 345kV Oil-Filled Cable (345kV OF 케이블 보통접속재의 절연설계에 관한 연구)

  • Lee, Jung-Bum;Kang, Dong-Sik;Kang, Do-Hyun;Lee, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.308-311
    • /
    • 1990
  • This paper presents the insulation design of 345kV OF cable normal joint which is essential to construction of underground transmission system. The insulation designs of stress relief cone, pencilling and sleeve were proposed in this paper, and the final insulation design was decided by the results of the electric field and thermal analysis using FEM. It is shown that the designed normal using proves the effect when the developing test is carried out to construct 345kV OF cable if the domestic underground transmission system.

  • PDF

The Analysis of HVDC Cable Oil Swelling Characteristics on the Silicone Rubber (HVDC 절연유 중에서 Silicone Rubber의 팽윤특성 분석)

  • Lee, T.H.;Kim, N.Y.;Kim, J.N.;Jeon, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.623-624
    • /
    • 2007
  • This work examines the effects of swelling MI type HVDC cable oil on the semiconductive silicone rubber and silicone rubber as used in accessories for application on outdoor termination (EBA) slip on sleeve. The behavior of volume resistivity is monitored as a function of the amount of cable oil diffused into the material. Resistivities of semiconductive silicone samples up to the typical insulator range (${\sim}10^{10}{\Omega}-cm$) are observed as a consequence of swelling due to the presence of the diffused oil. The measured volume resistivities of the oil-impregnated semiconductive silicone rubber are compared to desired value as function of stress relief cone.

  • PDF

Performance Evaluation of 154 kV Separable Dry Type Plug-in Connector (154 kV 건식형 지중종단접속함의 성능 평가)

  • Kim, Seok-Sou;Park, Young-Chang;Oh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.470-471
    • /
    • 2007
  • Underground connectors in 154kV for the connection between power cables and power equipments represent a greater part of power system stability and reliability. This paper presents the performance evaluation of 154kV separable dry type plug-in connector of a company in Japan for transformers and Gas Insulated Switchgear. And the possibility of the application on domestic underground line was considered.

  • PDF

A Evaluation Technique for Reliability of Extra-High Voltage Cable Accessories using High Frequency Partial Discharge Measurement (고주파 부분방전 측정에 의한 초고압 접속함 신뢰성 평가 기술)

  • Sin, Du-Seong;Lee, Chang-Yeong;Kim, Chung-Sik;Jeon, Seung-Ik;Kim, Dong-Uk;Park, Wan-Gi
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.3
    • /
    • pp.186-195
    • /
    • 2000
  • In this paper, partial discharge (PD) measurement was performed to evaluate the quality of the cable joint and termination constructions. The resistive coupling technique for PD detection using resistivity of semiconducting layer of the cable in the accessories, such as joints and terminations. With high frequency PD (HEPD) measurement, an excellent sensitivity below 20pC could be achieved under unshielded condition. The localization of the defects in the accessories could be identified. During heating cycle, PDs were monitored and analyzed. At that time, the PDs were dependent on the temperature of the heating cycle and showed cyclic behaviors, which were attributed to local delamination of the interfaces, between epoxy unit and stress relief cone(SRC) and between SRC and cable, due to the difference of thermal expansion. As a conclusion, HFPD measurement technique was proven to be an effective diagnostic method for qualification of extra high voltage (EHV) cable accessories. With this technique, the optimal design of the components of the accessories could be verified not only in an early stage but also under operating condition. This technique would result in the improvement of the reliability of the EHV cable accessories.

  • PDF

Breakdown Voltage and Partial Discharge Characteristics at the Simulated Interface in a Prefabricated Joint for Ultra High Voltage Cable (초고압용 조립형 접속함 모의계면에서 압력에 따른 절연파괴 및 부분방전 특성)

  • Kim, J.N.;Baek, J.H.;Shin, D.S.;Lee, C.Y.;Kim, C.S.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1099-1101
    • /
    • 1999
  • PJB(Prefabricated Joint Box) is consisted of three major components ; an epoxy unit, a stress relief cone and a spring unit. The insulation structure of PJB is maintained by the interfacial pressure, and the dielectric performance at the interface depends on the interfacial pressure which is regarded as the most important factor for preventing breakdown failure. This experiment was performed to investigate breakdown voltage characteristic and partial discharge patterns under the controlled pressure conditions at the simulated interface. Finally, this paper presents the optimal pressure conditions at the interface by analyasing the PD patterns.

  • PDF