• 제목/요약/키워드: Submerged biofilm process

검색결과 12건 처리시간 0.033초

굴패각을 담체로 사용한 침적고정 생물막공법 및 예측 (The Submerged Biofilm Process using Oyster-Shell Media for Wastewater Treatment and Prediction)

  • 문병현;이택순
    • 한국환경과학회지
    • /
    • 제6권6호
    • /
    • pp.671-678
    • /
    • 1997
  • This study was conducted to use oyster shell as media for biological wastewater treatment. The comparison between the removal efficiencies of the activated sludge and the submerged biofilm process with oyster shell media (5% of reactor volume) for domestic sewage treatment was made. The contaminant removal efficiencies of the submerged process were higher than that of the activated sludge process. And the removal efficiencies of the submerged biofilm process with oyster shell media of 10% and 18% were Investigated at various loading rate. The removal efficiencies of 10% were higher than that of the 18% during the experimental period. The effluent concentration from the sub- merged bloom process using oyster shell media was prediceted by the Stover-Kincannon model.

  • PDF

침지형 생물막공법에 있어서 포기강도가 처리효율에 미치는 영향 (Effect of Aeration Intensity on the Treatment Efficiency in Submerged Biofilm Process)

  • 박종웅
    • 한국환경보건학회지
    • /
    • 제15권1호
    • /
    • pp.89-96
    • /
    • 1989
  • An aerated submerged biofilm reactor is the reactor in which influent organic substrates are aerobically oxidized by suspended biomass and attached biomass of biofilm grown on the surface of submerged media. The objective of this study was to investigate the effect of aeration intensity on microbial characteristics and treatment efficiency in submerged biofilm process. In the organic loading rate (4.3kg BOD/$m^{3} \cdot day$), biofilm thickness (420-780$\mu$m) and attached biomass(1.79-2.94mg/cm$^{2}$) increased as the aeration intensity increased (2-8m$^{3}$ air/$m^{2} \cdot hr$), but biofilm density decreased (42.25-37.69mg/cm$^{3}$). The minimum aeration intensity for prevention of deposited biomass was 2m$^{3}$ air/$m^{2} \cdot hr$. The minimum dissolved oxygen of 2.5mg/l had to be maintained for improved efficiency.

  • PDF

호기성 침지형 생물막법을 이용한 Polyester 감량폐수의 처리 (Treatment of Polyester Weight Loss Wastewater by Aerated Submerged Biofilm Process)

  • 박종웅;김대희
    • 한국환경보건학회지
    • /
    • 제23권3호
    • /
    • pp.85-90
    • /
    • 1997
  • The objective of this study was to investigate biodegradation of TPA(terephthalic acid) and EG (ethylene glycol), treatment efficiency of polyester weight loss wastewater and microbial characteristics by aerated submerged biolfilm(ASB) p.rocess. In a batch reactor, pH increased from 7.0 to 8. 5 in the biodegradation of TPA. Whereas, in case of EG, decreased from 7.0 to 5.2. COD concentration rapidly decreased within 24hr in the biodegradation of TPA and EG. COD removal velocity constant(k) were 0.065-0.088 hr$^{-1}$. The biodegradation velocity of TPA was 1.4 times faster than that of EG. The ratio of suspended biomass to the total biomass in the reactor was 18.3-33.3%, increased as a high ratio of EG content. Biofilm thickness, biofilm dry density and attached biomass were 346-432 $\mu$m, 41.8-61.9 mg/cm$^3$, 1.45-2.67 mg/cm$^2$, respectively. There values increased as a high ratio of TPA content. In the hydraulic retention time of 36 hr, organic loading rate of 4 kgCOD/m$^3\cdot$ day and packing ratio of 70%, the effluent concentrations of TCOD, SCOD in a continuous flow reator were 1,388 mg/l, 147 mg/l and removal efficiencies were 77%, 97.6%, respectively.

  • PDF

호기성(好氣性) 침지형(浸漬型) 생물막공법(生物膜工法)에서 온도(溫度)가 처리효율(處理効率)에 미치는 영향(影響) (Effect of Temperature on the Treatment Efficiency in Aerated Submerged Biofilm Process)

  • 박종웅;유명진
    • 대한토목학회논문집
    • /
    • 제11권1호
    • /
    • pp.189-196
    • /
    • 1991
  • 본(本) 연구(硏究)에서는 침지형(浸漬型) 생물막(生物膜) 반응조(反應槽)에서 온도(溫度)의 변화(變化)가 미생물(微生物) 성상(性狀)과 처리효율(處理効率)에 미치는 영향(影響)을 구명(究明)하였다. 침지형(沈漬型) 생물막(生物膜) 반응조(反應槽)에서 온도와 매체충전율(媒體充塡率)을 변화시켜 얻어진 연구결과를 요약(要約)하면 다음과 같다. 1. 생물막(生物膜) 밀도(密度), 부착미생물량(附着微生物量), 생물막(生物膜)두께는 온도(溫度)와 매체충전량(媒體充塡量)의 변화에 상당한 영향을 받는다. 2. 반응조 내의 총(總) 미생물(微生物) 중 부유미생물(浮遊微生物)이 차지하는 비율은 약 10-50%로 부유미생물(浮遊微生物)이 기질제거(基質除去)에 관여하는 역할을 무시할 수 없음이 입증되었다. 3. 온도와 총 미생물농도에 따른 BOD 제거효율(除去効率)을 나타내는 관계식을 유도할 수 있었다. 4. 본 공법(工法)은 온도변화에 강(強)한 편으로, Van't Hoff-Arrhenius 변형식(變形式)을 이용하여 구(求)한 온도보정계수(溫度補正係數)는 1.042이었다.

  • PDF

완전침지형 회전매체 생물막 공정에서 포기강도 조절이 동시 질산화/탈질 효율에 미치는 영향 (Effect of Aeration Intensity on Simultaneous Nitrification and Denitrification Efficiency in the Submerged Moving Media Biofilm Process)

  • 김준명;이상민;임경호;김일규;강호
    • 한국물환경학회지
    • /
    • 제24권3호
    • /
    • pp.273-279
    • /
    • 2008
  • Space separation method that use independent reactor for nitrification and other reactor for denitrification has been commonly used for biological nitrogen removal process like $A^2O$ process. However, this method needs large space and complicate pipelines and time separation method such as SBR process have a difficulty in continuous treatment. Thus biological nitrogen removal process which is capable of continuous treatment, easy opeation and space saving is urgently required. In this research, submerged moving media was used for a biofilm process and suspended sludge was used for biological nitrogen removal at the same time. In particular DO environment by controlling air flow rate was investigated for simultaneous nitrification/denitrification. Total nitrogen removal in aeration rate more than $67L/min{\cdot}m^3$ showed 51~53% and rose to 65%, 70% and 78% in $50L/min{\cdot}m^3$, $58L/min{\cdot}m^3$ and $25L/min{\cdot}m^3$ respectively. Total phosphorus removal was very low about 10~20% more than $67L/min{\cdot}m^3$ aeration rates. But total phosphorus removal roses when reduces aeration rate by $58L/min{\cdot}m^3$ low and it showed total phosphorus removal of 72% in aeration rate $25L/min{\cdot}m^3$.

군용시설물(軍用施設物) 폐수처리(廢水處理)를 위한 고정생물막공법(固定生物膜工法)의 연구(硏究) (A Study on the Aerated Submerged Fixed-Film Bioreactor for Military Installation Wastewater Treatment)

  • 서형석;유성호
    • 상하수도학회지
    • /
    • 제7권1호
    • /
    • pp.37-45
    • /
    • 1993
  • This research was performed to examined the applicability of a fixed-biofilm process for the wastewater treatment of military installations. Utilizing plastic net media, synthetic wastewater-average $BOD_5$ cocentration was $192mg/l$ treated in the three sets of reactors that have 8 hours, 6 hours, and 4 hours of hydraulic retention time. The results of this experiment showed that the biofilm was not detached easily, and the reactor was not closed by excess biomass. The average soluble $BOD_5$ concentrations of effluent were $6.0mg/l$ with 8 hours of retention time, $11.3mg/l$ with 6 hours of retention time, and $19.4mg/l$ with 4 hours of retention time. Especially it was reduced to $5.7mg/l$ in the second stage reactor with 4 hours of retention time. These resulted that the fixed-biofilm process could be adapted for the treatment of military installation wastewater.

  • PDF

생물막 반응기에서 아질산성 질소의 축척에 미치는 영향인자 (Parameters Affecting Nitrite Accumulation in Submerged Biofilm Reactor)

  • 황병호;황경엽;최의소
    • 대한환경공학회지
    • /
    • 제22권10호
    • /
    • pp.1789-1797
    • /
    • 2000
  • 질산화에 요구되는 산소량과 탈질소화에 요구되는 탄소원의 양을 감소시킬 수 있는 암모니아성 질소의 아질산성 질소로의 부분적 질산화 반응을 유도하기 위해 생물막 반응기를 이용하여 고농도 암모니아성 질소를 함유하고 있는 혐기성 소화슬러지 탈수여액을 대상으로 알칼리도/암모니아성 질소의 농도비, pH, FA(free ammonia), 온도변화에 따른 아질산성 질소의 축적현상에 대한 연구를 수행하였다. 실험결과 유입수의 알칼리도/암모니아성 질소의 농도비를 증가시킴에 따라 유출수의 아질산성 질소의 축적도 증가하였으며, 이는 알칼리도의 농도가 증가함에 따라 반응기내의 pH가 높게 유지됨으로서 FA의 농도가 증가하게 되어 Nitrobacter의 성장을 선택적으로 저해시키기 때문인 것으로 판단된다. 일정한 알칼리도/암모니아성 질소의 농도비 조건에서 온도가 증가할수록 아질산성 질소의 축적도 증가하였다.

  • PDF

Removal of Organic Load from Olive Washing Water by an Aerated Submerged Biofilter and Profiling of the Bacterial Community Involved in the Process

  • Pozo, Clementina;Rodelas, Belen;Martinez-Toledo, M. Victoria;Vilchez, Ramiro;Gonzalez-Lopez, Jesus
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권5호
    • /
    • pp.784-791
    • /
    • 2007
  • The present work aims to use a biofilter technology(aerated submerged filters) for the aerobic transformation at laboratory-scale of olive washing water(OWW) generated in the first steps of olive oil processing, as well as the genetic profiling and identification to the species level of the bacteria involved in the formation of the biofilm, by means of TGGE. Chemical parameters, such as biological oxygen demand at five days($BOD_5$) and chemical oxygen demand(COD), decreased markedly(up to 90 and 85%, respectively) by the biological treatment, and the efficiency of the process was significantly affected by aeration and inlet flow rates. The total polyphenol content of inlet OWW was only moderately reduced(around 50% decrease of the inlet content) after the biofilter treatment, under the conditions tested. Partial 16S rRNA genes were amplified using total DNA extracted from the biofilm and separated by TGGE. Sequences of isolated bands were mostly affiliated to the $\alpha-subclass$ of Proteobacteria, and often branched in the periphery of bacteria] genera commonly present in soil(Rhizobium, Reichenowia, Agrobacterium, and Sphingomonas). The data obtained by the experimentation at laboratory scale provided results that support the suitability of the submerged filter technology for the treatment of olive washing waters with the purpose of its reutilization.

폭기식 잠수여상을 이용한 고밀도 양식장의 순환수 처리 -1. 해수중의 암모니아 제거 특성- (The Recycling Water Treatment of High Density Fish Culture System Using the Aerated Submerged Filter -1. Ammonia Removal Characteristics in Sea Water-)

  • 이헌모;이재관;정병곤;양병수
    • 한국수산과학회지
    • /
    • 제26권5호
    • /
    • pp.502-509
    • /
    • 1993
  • Submerged filter process was used to evaluate the nitrifying efficiency of ammonia in the recycling water of marine aquatic culture system. The ammonia removal efficiency was achieved as high as $99\%$ at the hydraulic surface loading rate of up to $4.3{\ell}/m^2-day$. And the nitrite accumulation did not occur in the reactor even when the hydraulic surface loading rate of up to $36.8{\ell}/m^2day$ was applied. In the present study, the relationship between the effluent ammonia concentration and ammonia surface loading rate was formulated as an equation. The attachment rate of biofilm on the filter media at the ammonia surface loading rate of 62.3 and $311.7mg/m^2day$ was 15 and $55mg/m^2-day$, respectively, showing the linear relationship between the attachment rate and ammonia loading rates. Biofilm thickness and density of the filter media were found to be the function of the ammonia loading rate.

  • PDF

생물막 끈상여재를 이용한 낙차형태별 수중 미량유해물질 ibuprofen, acetaminophen, caffeine분해특성 (Removal characteristic on micropollutants as ibuprofen, acetaminophen, caffeine in small water fall system using HBC ring media)

  • 독고석
    • 상하수도학회지
    • /
    • 제23권1호
    • /
    • pp.129-135
    • /
    • 2009
  • PPCP (pharmaceuticals and personal care products) is known as micropollutant that is released from wastewater treatment plant. Research represents that these contaminants have increased in the last 10 years. This study tries to make four different trickling filter systems using plastic fiber media to remove PPCP such as acetaminophen, ibuprofen, caffeine. The results of the experiment that compares the process efficiencies of four different systems (A, B, C and D) using HBC media show that almost all the reactor has around 95% removal efficiency. Slope type HBC reactor has twice higher efficiency rather than submerged type reactor to remove PPCP in water system. In 8 hours, 89% of acetaminophen, ibuprofen, caffeine are removed in slope type reactor while 39% of them in submerged type.