• Title/Summary/Keyword: Substation

Search Result 996, Processing Time 0.033 seconds

A Study on Description of IEC 61850 based Substation Topology for Implementing the Engineering Tool of Digital Substation (디지털변전소 엔지니어링 툴 구현을 위한 IEC 61850 국제규격 기반의 변전소 토폴로지 표현에 관한 연구)

  • Lee, Nam-Ho;An, Yong Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.23-32
    • /
    • 2015
  • In order to complete engineering works of the digital substation, Both Data transmission among a variety of IEDs and HMIs, and single line diagram of the substation might be done based on XML documents published in IEC 61850 international standards. This kind of XML based engineering process for the digital substation must be implemented not by manual written work but by the engineering tool using a computer. But most of the engineering tools do not support system based engineering works such as single line diagram of the substation but have only function to set IEDs as single device unit. Accordingly, this paper presents a new design method of the system based engineering description applicable to real IEC 61850 based substation through analyzing the current international standard and its sampled engineering file, and shows implementation of the engineering tool of the digital substation with the result of this study.

Planning for Construction and Expanding of Distribution Substation Considering Contingency (상정사고를 고려한 배전용 변전소 신,증설 계획 수립)

  • Choi, Sang-Bong;Kim, Dae-Kyeong;Jeong, Seong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.7
    • /
    • pp.303-308
    • /
    • 2001
  • This paper presents algorithm to plan construction and expanding of substation considering contingency accidents by proposing utilization factor according to configuration of substation bank system. In this paper, firstly, proper sphere of supply area by each district which could be standardized with respect to its supply capacity is established under assumption of long term load forecasting. Secondly, goal of utilization ratio based on configuration of substation bank was set to keep reliability by remaining sound bank when it happen to one bank accidents. Finally, it is set up for optimal construction and expanding of substation considering economy and reliability simultaneously about substation to exceed these ratio. To verify proposed algorithm, at first, after adopting a part of Kangnam area in Seoul as area for testing, it is divided into several regions for this area according to power branches of power utility. Secondly, by deriving correlation factor between load demand and economic indicators in these region respectively, the regional load forecasting was performed with economic growth and city plan scenario. Finally, based on the predicted load demand by region and land use data which is identified from air-photographic, the load demand by district was predicted. Also, planning for substation considering contingency is formulated to expand taking into account computing utilization factor which is based on configuration of substation bank respectively.

  • PDF

Seismic Fragility Analysis of Substation Systems by Using the Fault Tree Method (고장수목을 이용한 변전소의 지진취약도 분석)

  • Kim, Min-Kyu;Choun, Young-Sun;Choi, In-Kil;Oh, Keum-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.47-58
    • /
    • 2009
  • In this study, a seismic fragility analysis was performed for substation systems in Korea. To evaluate the seismic fragility function of the substation systems, a fragility analysis of the individual equipment and facilities of the substation systems was first performed, and then all systems were considered in the fragility analysis of the substation systems using a fault-tree method. For this research, the status of the substation systems in Korea was investigated for the classification of the substation systems. Following the classification of the substation systems, target equipment was selected based on previous damage records in earthquake hazards. The substation systems were classified as 765kV, 345kV, and 154kV systems. Transformer and bushing were chosen as target equipment. The failure modes and criteria for transformer and bushing were decided, and fragility analysis performed. Finally, the fragility functions of substation system were evaluated using the fault tree method according to damage status.

A Study on the Substation for the Bad Measuring Devices Detection and Correction (변전소 측정기기의 검.교정 알고리즘에 관한 연구)

  • Lee, H.J.;Park, S.M.;Kim, Y.H.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.313-315
    • /
    • 2001
  • The power system automation, especially the substation automation is a major issue. so it has been widely studied each country in the world. Since the substation system includes lots of measuring devices. a lot of data and system information are transmitted to operators. The measured values usually have the error that results from the communication process, and it can degrade the reliability of estimated values. So. the detection and correction of measured values at a substation are important factors for substation automation. In this paper, we study the detection and col of measured values at the domestic 154kV/2 distribution substation of double bus structure study will be useful for expected economic dispatch measuring device's inspection and corr management by SCADA system operation, substation automation.

  • PDF

SCL based HMI Development Methodology for IEC 61850 SAS (IEC 61850 자동화 변전소에 SCL 기반 HMI 개발방법 연구)

  • Choi, Young-Jun;Kim, Tae-Wan;Choi, Myeon-Song;Lee, Seung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.255-261
    • /
    • 2010
  • In this paper, a substation HMI based on IEC 61850 is proposed that uses SCL to have all information in substation to include standard concept of IEC 61850. A proposed substation HMI using SCL based on IEC 61850 expresses different display by each substation structure and component device change in substation. A proposed substation HMI is designed by IEC 61850 standard, and it suits for future substation HMI based on IEC 61850. A proposed HMI is proved by a program that is made by Visual C++ to use SCL file based on XML.

Development of an Intelligent Station HMI in IEC 61850 Based Substation

  • Rim, Seong-Jeong;Zeng, Sheng-Wu;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • Because the existing Human-Machine Interface (HMI) for the conventional substation cannot dynamically indicate the configuration information of the Substation Automation System (SAS). In this paper, an intelligent station HMI is proposed for IEC 61850 based substation. The program of the proposed HMI not only can automatically generate the layout of single line diagram, but can also indicate the communication network and functions of IEDs by reading SCL files. It greatly helps monitor the operation status, communication network and each IED dynamically, such as failure detection in SAS. Furthermore, this paper presents the possibility of developing new software for SAS with the full use of IEC 61850-6. Once the software is complete, there is no need to change it when the substation is upgraded or when it is migrated to other IEC 61850 based substations, which is a cost-effective solution.

Prototype design of fiber optics based 765kV substation control system (광 LAN을 적용한 765kV변전소 감시제어 시범시스템 설계)

  • 송인호;박종화;최종협
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.996-999
    • /
    • 1996
  • This paper introduces prototype design of 765kV Substation control system based on fiber optics LAN and distributed network protocol. Two major important facts, immunity of any surge which frequently occurs in Ultra High Voltage Substation and the most suitable communication protocol for substation control system, are considered on the system design conception. To meet the first fact, use of fiber optics cable and isolation transformer are considered, and to satisfy the second fact, DNP3.0(Distributed Network Protocol) which is IEC870-5 compatible is adopted.

  • PDF

R&D Trends of Substation Automation (변전소 종합 자동화 기술개발 동향)

  • Lee, Bong-Hee;Park, Soon-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.548-550
    • /
    • 2002
  • In this paper the domestic and worldwide trends of substation automation are described in order to cope with the coming new environment in this part On the world market of substation control it will be change from analog technology to digital technology. And the technology of a system integration relevant to a substation automation become more important than that of individual power apparatus. Therefore development of substation automation technology is needed.

  • PDF

Application Standards for Substation Types and Facility Scales (변전소 형태 및 설비규모의 결정)

  • Min, Byeong-Wook;Shin, Myoung-Sik;Bahng, Seon-Woong;Kim, Young-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.438-439
    • /
    • 2011
  • Substations in Korea are classified into an outdoor steel structure type, an outdoor GIS(Gas Insulated Switchgear) type, an indoor GIS type, an underground GIS type, and a complex GIS type. Before 1970, substations were built in outdoor steel structure types only. In 1980, an 154kV indoor GIS type substation was built for the first time in Pusan. And the first 345kV indoor GIS type substation, the first 765kV full GIS substation were built in 1984 and in 2002 each. In 1998, 154kV indoor type substations were standardized into regular type and urban type which applied steel frames to structures. In 2002, this was re-standardized into five different types in detail. In 2007, hub substations which had high capacity were built in the region of industrial zone and heavy load areas. And 154kV compact substation was developed and standardized by compacting an indoor GIS type substation in 2009. This paper would present a series of substation type transition and application standards for substation types and facility scales.

  • PDF

Assessing the Impact of Advanced Technologies on Utilization Improvement of Substations

  • Han, Dong;Yan, Zheng;Zhang, Dao-Tian;Song, Yi-Qun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.1921-1929
    • /
    • 2015
  • The smart substation is the heart of a transmission system, which is particularly emphasized as the most significant composition of smart grids in China. In order to assess the functionality performance of substation technologies, this paper presents methods used to identify the most promising solutions for smart substation design and to evaluate the technical levels of available technologies. The multi-index optimization model is presented to address the issue of smart substation planning. A mathematical model of the planning decision problem is established with multiple objectives consisting of economic, reliability, and green key indices, and many kinds of concerns including physical and environmentally friendly operations are formulated as a set of constraints. With respect to the assessment of the technical level regarding integration of advanced technologies into a substation, a modified grey whitenization weight function is adopted to structure a novel grey clustering method. The proposed grey clustering approach is used to overcome the difficulty of insufficient quantitative assessment capacity for traditional methods. The evaluation of technical effects provides the classification definition for the development phase and the maturity level of the smart substation. The effectiveness of the proposed approaches in planning decision-making and evaluation of construction efforts is demonstrated with case studies involving the actual smart substation projects of Wenchongkou substation in China Southern Power Grid (CSG) and Mengzi substation in State Grid Corporation of China (SGCC).