• Title/Summary/Keyword: Suction surface

Search Result 303, Processing Time 0.029 seconds

Numerical Simulation on Dispersion of Fume Micro-Particles by Particle Suction Flows in Laser Surface Machining (입자 석션유동에 따른 레이저 표면가공의 마이크로 흄 오염입자 산포 특성 해석연구)

  • Kyoungjin Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.1-6
    • /
    • 2023
  • In CO2 laser surface machining of plastic films in modern display manufacturing, scattering of fume particles could be a major source of well-recognized film surface contamination. This computational fluid dynamics research investigates the suction air flow patterns over a film surface as well as the dispersion of micron-sized fume particles with low-Reynolds number particle drag model. The numerical results show the recirculatory flow patterns near laser machining point on film surface and also over the surface of vertical suction slot, which may hinder the efficient removal of fume particles from film surface. The dispersion characteristics of fume particles with various particle size have been tested systematically under different levels of suction flow intensity. It is found that suction removal efficiency of fume particles heavily depends on the particle size in highly nonlinear manners and a higher degree of suction does not always results in more efficient particle removal.

  • PDF

Effect of the suction plate shape on metering performance of a vacuum metering device for garlic seeds

  • Kim, Deok-Keun;Choi, Yeong-Soo;Yang, Seung-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.4
    • /
    • pp.829-844
    • /
    • 2020
  • A vacuum metering device for garlic seeds was developed, and its metering performance was tested according to the design factors. Three design factors were as follows: suction surface diameter (Edge), suction surface curvature (Type), and guide height (Guide). The suction surface curvature represents the distance between the center of the grooved suction plate and the bottom of suction plate. The metering rate and multiple metering rate were analyzed as the metering performance of the developed device with two varieties of garlic seeds: Namhae (warm region-adapted garlic) and Uiseong (cold region-adapted garlic). The best metering performance for the Namhae seeds were found with the following conditions: An Edge, Guide and Type of 40, 4, and 35 mm, respectively. In the case of the Uiseong seeds, the best conditions were as follows: An Edge, Guide and Type of 35, 4, and 30 mm, respectively. The guide height was found to be the most influential design factor on the metering performance of the metering rate and multiple rate for both Namhae seeds and Uiseong seeds. Additionally, the interaction between the area of the suction surface and the curvature of the suction surface had some effects on the multiple rate for the Uiseong seeds. It was concluded that the guide height should be 4 mm or higher so that more than 90% of the metering rate could be achieved for the tested garlic seeds with the developed metering device.

Experimental Investigation on Separated Flows of Axial Flow Stator and Diagonal Flow Rotor

  • Kinoue, Yoichi;Shiomi, Norimasa;Setoguchi, Toshiaki;Jin, Yingzi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.3
    • /
    • pp.223-231
    • /
    • 2009
  • Experimental investigations were conducted for the internal flows of the axial flow stator and diagonal flow rotor. Corner separation near the hub surface and the suction surface of stator blade are mainly focused on. For the design flow rate, the values of the axial velocity and the total pressure at stator outlet decrease between near the suction surface and near the hub surface by the influence of corner wall. For the flow rate of 80-90% of the design flow rate, the corner separation of the stator between the suction surface and the hub surface is observed, which becomes widely spread for 80% of the design flow rate. At rotor outlet for 81% of the design flow rate, the low axial velocity region grows between near the suction surface of rotor and the casing surface because of the tip leakage flow of the rotor.

A model of roof-top surface pressures produced by conical vortices : Evaluation and implications

  • Banks, D.;Meroney, R.N.
    • Wind and Structures
    • /
    • v.4 no.4
    • /
    • pp.279-298
    • /
    • 2001
  • The greatest suction on the cladding of flat roof low-rise buildings is known to occur beneath the conical vortices that form along the roof edges for cornering winds. In a companion paper, a model of the vortex flow mechanism has been developed which can be used to connect the surface pressure beneath the vortex to adjacent flow conditions. The flow model is experimentally validated in this paper using simultaneous velocity and surface pressure measurement on a 1 : 50 model of the Texas Tech University experimental building in a wind tunnel simulated atmospheric boundary layer. Flow visualization gives further insight into the nature of peak suction events. The flow model is shown to account for the increase in suction towards the roof corner as well as the presence of the highest suction at wind angles of $60^{\circ}$. It includes a parameter describing vortex suction strength, which is shown to be related to the nature of the reattachment, and also suggests how different components of upstream turbulence could influence the surface pressure.

A study on evaluation of duplex loading pressure in Suction Drain Method (Suction Drain 공법에서 양방향 압력재하에 의한 효율 평가에 관한 연구)

  • Ahn, Dong-Wook;Chae, Kwang-Seok;Han, Sang-Jae;Yoon, Myung-Seok;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1256-1263
    • /
    • 2010
  • Suction Drain Method is soft ground improvement technique, in which a vacuum pressure can be directly applied to the Vertical Drain Board to promote consolidation and strengthening the soft ground. This method does not require a surcharge load, different to embankment or Preloading Method. In this study, ground improvement efficiency of suction drain method was estimated when duplex loading pressure with vacuum and pressure. During suction drain method process, surface settlement and pore pressure were monitored, and cone resistance test as well as water content were also measured after the completion of Suction Drain Method treatment.

  • PDF

Studies on the flow stabilization around the turbine suction with utilizing the surface water overflow at small-hydraulic power plant (표층수의 월류를 통한 소수력빌전소 수차터빈측의 유동안정화 연구)

  • Lee, Sungmyung;Kim, Cheolhan;Yoo, Gunjong;Kim, Wonseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.165.2-165.2
    • /
    • 2011
  • Flow with suction to water turbine must be in stable state at small hydraulic power plant. But because of water level fluctuation and water gate effect according to irregular supply of cooling water, it would happen to produce bubble and vortex and finally lead to problems in power-plant system. With utilizing the concept design of double size gate, surface water overflowed the overhead of gate for stable flow at suction. We developed the overflow condition and analyzed the design factor with existed one such as water level(overflow amount) and overhead of water gate(overflow figure). Flow test and CFD simulation say that flow have stable state around suction and 20% of wave reduction effect at surface layer after surface water overflow.

  • PDF

Yield Surface and Hardening Laws of Unsaturated Clayey Soils for Isotropic Compression (불포화 점성토의 등방압축 상태에서 발생하는 항복곡면과 경화감수)

  • 송창섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.1
    • /
    • pp.93-101
    • /
    • 1997
  • This paper presents yield surfaces and hardening laws for describing the state of an unsaturated soil under isotropic compression and suction changes. The yield surface is formulated within the framework of hardening plasticity using two independent sets of stress variables : the excess of total stress over air pressure and the suction. And the application of the yield surfaces and hardening laws are confirmed from the result of the experiment. To this end a series of suction-controlled isotropic tests are conducted on clayey soils. Matric suction is controlled by the axis translation technique using high air entry ceramic disk. The specimens are compacted using a half of Proctor compaction energy with 5 % lower of water content than the optimum moisture contents. From test results, existence of the yield surfaces and an application of hardening laws to samples are confirmed by comparison between test and predicted results. And it is confirmed that LC yield locus is extened with the total plastic deformations induced by suction or stress changes, however, SI yield locus is only extended with the plastic deformations by induced suction changes.

  • PDF

Assessment of Air Flow Misalignment Effects on Fume Particle Removal in Optical Plastic Film Cutting Process

  • Kim, Kyoungjin;Park, Joong-Youn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.51-58
    • /
    • 2020
  • Many types of optical plastic films are essential in optoelectronics display unit fabrication and it is important to develop high precision laser cutting methods of optical films with extremely low level of film surface contamination by fume particles. This study investigates the effects of suction and blowing air motions with air flow misalignment in removing fume particles from laser cut line by employing random particle trajectory simulation and probabilistic particle generation model. The computational results show fume particle dispersion behaviors on optical film under suction and blowing air flow conditions. It is found that suction air flow motion is more advantageous to blowing air motion in reducing film surface contamination outside designated target margin from laser cut line. While air flow misalignment adversely affects particle dispersion in blowing air flows, its effects become much more complicated in suction air flows by showing different particle dispersion patterns around laser cut line. It is required to have more careful air flow alignment in fume particle removal under suction air flow conditions.

The Shear Characteristics of Unsaturated Sandy Soils (불포화 사질토의 전단특성)

  • Lim, Seong-Yoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.10
    • /
    • pp.57-64
    • /
    • 2007
  • Since matric suction of unsaturated soil was related to soil and ground water contaminations, it is very important to analyze its mechanism that was represented by shear characteristics. In three phases of soil, a little air makes the condition of unsaturated soil on contract or shrinkage surface between water and air. Capillarity and suction in pore of unsaturated soil cause surface tension and surface force so it makes negative pore water pressure and increases effective stress as a result. Therefore, negative pore water pressure in partially saturated soil affects the soil structure and degree of saturation and it is important to evaluate accurately unsaturate flow and behavior. In this study, the shear strength characteristics of the seven sandy soils were investigated using consolidated drained triaxial tests with special emphasis on the effects of the negative pore pressure and the matric suction. These tests involved shearing under either a constant net confining pressure and varying matric suction or under a constant matric suction and varying net normal stress.

Vortices within a Three-Dimensional Separation in an Axial Flow Stator of a Diagonal Flow Fan

  • Kinoue, Yoichi;Shiomi, Norimasa;Setoguchi, Toshiaki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.2
    • /
    • pp.262-270
    • /
    • 2011
  • Experimental and numerical investigations were conducted for an internal flow in an axial flow stator of a diagonal flow fan. A corner separation near the hub surface and the suction surface of a stator blade was focused on, and further, three-dimensional vortices in separated flow were investigated by the numerical analysis. At low flow rate of 80% of the design flow rate, a corner separation of the stator between the suction surface and the hub surface can be found in both experimental and calculated results. Separation vortices are observed in the limiting streamline patterns both on the blade suction and on the hub surfaces at 80% of the design flow rate in the calculated results. It also can be observed in the streamline pattern that both vortices from the blade suction surface and from the hub surface keep vortex structures up to far locations from these wall surfaces. An attempt to explain the vortices within a three-dimensional separation is introduced by using vortex filaments.