• Title/Summary/Keyword: Sulfur detection

Search Result 72, Processing Time 0.024 seconds

Monitoring of Residual Sulfur Dioxide in Herbal Medicines (유통 한약재의 잔류이산화황에 대한 모니터링)

  • Kim, Mi-Kyeong;Hur, Moon-Hye;Lee, Chang-Hee;Jin, Jong-Seong;Jin, Sun-Kyung;Lee, Young-Ja
    • Korean Journal of Pharmacognosy
    • /
    • v.35 no.4 s.139
    • /
    • pp.276-282
    • /
    • 2004
  • This study has been conducted to investigate the amount of residual sulfur dioxide for herbal medicines of 30 species which are purchased in 13 different regions (Bonghwa, Busan, Chunju, Jecheun, Kwangiu, Keumsan, Seoul, Taeku, Cheungdu, Xian, Beijing, Tokyo and Osaka). The sulfur dioxide residues were determined in the collected 386 samples by the modified Monier-Williams method. The residues of sulfur dioxide in 386 samples ranged from ND (under detection limit) to 2808 ppm. The sulfur dioxide in Cassiae Semon, Cinnamomi Ramulus, Cervi Cornu, Hoelen, Crataegi Fructus, Artemisiae Argyi Herba, Scolopendrae Corpus, Schizandrae Fructus and Cyperi Rhizoma were detected under the detection limit regardless of the collected regions. The sulfur dioxide residues in herbal medicines collected in domestic regions were relatively lower than those in foreign regions. There are no standards for sulfur dioxide residual limits of herbal medicines in Korea. This results will provide the scientific basis for the standardization of sulfur dioxide residues in Korea Pharmacopoeia.

Molecular Emission Spectrometric Detection of Low Level Sulfur Using Hollow Cathode Glow Discharge

  • Koo, Il-Gyo;Lee, Woong-Moo
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.73-78
    • /
    • 2004
  • A highly sensitive detecting method has been developed for determining part per billion of sulfur in $H_2S$/Ar plasma. The method is based on the excitation of Ar/$H_2S\;or\;Ar/H_2S/O_2$ mixture in hollow cathode glow discharge sustained by radiofrequency (RF) or 60 Hz AC power and the spectroscopic measurement of the intensity of emission lines from electronically excited $S_2^*\;or\;SO_2^*$ species, respectively. The RF or AC power needed for the excitation did not exceed 30 W at a gas pressure maintained at several mbar. The emission intensity from the $SO_2^*$ species showed excellent linear response to the sulfur concentration ranging from 5 ppbv, which correspond to S/N = 5, to 500 ppbv. But the intensity from the $S_2^*$ species showed a linear response to the $H_2S$ only at low flow rate under 20 sccm (mL/min) of the sample gas. Separate experiments using $SO_2$ gas as the source of sulfur demonstrated that the presence of $O_2$ in the argon plasma is essential for obtaining prominent $SO_2^*$ emission lines.

A Study on the Exhaust Emissions Characteristics of LPG Vehicle using LPG Fuel with Sulfur Free Odorant (비황분계 부취제를 혼합한 LPG 연료의 차량 배출가스 특성에 관한 연구)

  • Kim, Jae-Kon;Lee, Ho-Kil;Yim, Eui Soon;Jung, Choong-Sub
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.545-554
    • /
    • 2014
  • In general, odorant was added to fuel gases, such as LPG, LNG and city gas, to prevent gas poisoning, ignition, explosion, or other accident caused by fuel gases, and to enable immediate and easy detection of fuel-gas leakage by emitting an offensive smell. This study describes a study on the exhaust emissions characteristics and fuel economy of liquefied petroleum gas (LPG) vehicle using LPG fuel with new sulfur free odorant. New sulfur free odorant was added to LPG to reduce sulfur content of the LPG. Its performance and exhaust emission were compared to those of LPG with sulfur containing odorant (EM, ethyl mercaptan). Engine performance using LPG with sulfur free odorant was similar to that with sulfur-containing odorant. Exhaust emissions from the LPG vehicle with LPG including sulfur free odorant were also similar to those with LPG including sulfur containing odorant in the FTP 75 and NEDC mode. There experimental results suggest that the sulfur free odorant may substitute for the sulfur containing odorant in LPG fuel.

Development of an Analytical Approach to Measure Volatile Sulfur Compounds Using a Non-Cryogenic Preconcentration Method (비냉각형 선농축 방식에 의한 대기 중 휘발성 황화합물의 분석방법 개발)

  • 김기현;이강웅
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.5
    • /
    • pp.355-360
    • /
    • 1997
  • The atmospheric concentration of dimethylsulfide (DMS), known as the predominant volatile organic. sulfur compound, is determined at subnanogram level by a combined application of non-cryogenic preconcentration method and gas chromatography with flame photometric detection (GC/FPD). The volatile DMS in air is preconcentrated using a trapping tube containing adsorbent like Molecular Sieve 5A (or gold-coated sands). The tube is then connected to the GC/FPD system via a six-way rotary valve, thermally desorbed at 40$0^{\circ}C$, separated on OV101 column, and detected by a flame photometric detector. The DMS peak elutes at about 2.5 mins and is integrated electronically. The analytical precision, if expressed in terms of relative standard error, is around 5%. The detection limit of our GC/FPD system is ca 1 ng of DMS. Details of our analytical system are presented.

  • PDF

A New Methodology of Measuring Water Toxicity using Sulfur Oxidizing Bacteria (황산화미생물을 이용한 새로운 수(水)중 생태독성탐지 방법)

  • Oh, Sang-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.6
    • /
    • pp.555-562
    • /
    • 2010
  • For the rapid and reliable detection of toxic compounds in water, a novel toxicity detection methodology based on sulfur-oxidizing bacteria (SOB) has been developed. The methodology exploits the ability of SOB to oxidize elemental sulfur to sulfuric acid in the presence of oxygen. The reaction results in an increase in electrical conductivity (EC) and a decrease in pH. Using a synthetic stream water (EC=0.12 mS/cm and pH=7.2), the baseline steady-state EC and pH values were 0.5~1.2 mS/cm and ~2.5 over 7 days of testing at HRT 30 minutes. When nitrite compounds were added to the system, the effluent EC decreased and the pH increased due to the inhibition of the SOB. Optimum HRT was 30 min and this HRT could be decresed by using smaller sulfur particles.

A Study on the Distribution of Atmospheric Concentrations of Sulfur Compounds by GC/FPD (GC/FPD에 의한 대기 중 황화합물 농도분포에 관한 연구)

  • Yang, Sung Bong;Yu, Mee Seon;Hwang, Hee Chan
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.240-248
    • /
    • 2003
  • Sulfur compounds which are well-known odor-active compounds in industrial area have very low detection threshold values. Trace amounts of volatile sulfur compounds in enviroment air around several odor sources were concentrated in liquid argon bath and determined by gas chromatograph with flame photometric detector (FPD) which exhibits very good selectivity and sensitivity. 25% ${\beta}$,${\beta}$-Oxydipropionitrile on 60/80 Chromosorb W was used as adsorbent for the preconcentration of sulfur compounds in air sample and also as packing material for a packed glass column. Concentration volume of air sample was different from place to place in the range of 0.1~3.0L. Atmospheric concentrations of sulfur compounds in air of residential districts and boundaries of business establishments, and also those in the exhausted gases of emission points such as a sewage disposal plant in industrial area were measured.

Comparison of Solid Phase Microextraction-Gas Chromatograph/Pulsed Flame Photometric Detector (SPME-GC/PFPD) and Static Headspace-Gas Chromatograph/Pulsed Flame Photometric Detector (SH-GC/PEPD) for the Analysis of Sulfur-Containing Compounds (Solid phase microextraction-gas chromatograph/pulsed flame photometric detector(SPME-GC/PFPD)와 static headspace-gas chromatograph/pulsed flame photometric detector(SH-GC/PEPD)를 이용한 황 함유 화합물들의 분석 방법 비교)

  • Yang, Ji-Yeon;Kim, Young-Suk
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.695-701
    • /
    • 2005
  • Efficient method was established for analysis of sulfur-containing compounds, including dimethyl disulfide, dimethyl trisulfide, 3-methyl thiophene, allyl mercaptan, 2-methyl-3-furanthiol, and methional. Sulfur-containing compounds were extracted through solid phase microextraction (SPME) or static headspace extraction (SH), and quantified using gas chromatograph equipped with pulsed flame photometric detector. All sulfur compounds, except ally mercaptan, showed higher detection response when dissolved in hexane than in dichloromethane. Linear range was $10^2-10^4$. Dimethyl trisulfide showed lowest limit of detection (LOD) value of 15.2 ppt, and methional highest of 70.5 ppb. Highest extraction efficiency for sulfur-containing compounds, particularly polar and small molecular weight compounds, was observed in 75mm carboxen/polydimethylsiloxane fiber, followed by 65mm polydimethylsiloxane/divinylbenzene and 100mm polydimethylsiloxane. Compared to SPME, less sulfur-containing compounds could be analyzed by SH, mainly due to its low extraction efficiency, although lower amount of artifacts were formed during sample preparation.

Fluorescence-Quenched Sensor for Trinitophenol in Aqueous Solution Based on Sulfur Doped Graphitic Carbon Nitride

  • Min, Kyeong Su;Manivannan, Ramalingam;Satheshkumar, Angu;Son, Young-A
    • Textile Coloration and Finishing
    • /
    • v.30 no.2
    • /
    • pp.63-69
    • /
    • 2018
  • In this study, we report on successful attempt towards the synthesis of sulfur self-doped $g-C_3N_4$ by directly heating thiourea in air. The synthesized materials were characterized using UV-vis spectral technique, FT-IR, XRD and TEM analysis. Further, the obtained material shows an excellent detection of carcinogenic TNP(Tri nitro phenol) in the presence of 10-fold excess of various other common interferences. The strong inner filter effect and molecular interactions(electrostatic, ${\pi}-{\pi}$, and hydrogen bonding interactions) between TNP and the $S-g-C_3N_4$ Nano sheets led to the fluorescence quenching of the $S-g-C_3N_4$ Nano sheets with an excellent selectivity and sensitivity towards TNP compared to that of other nitro aromatics under optimal conditions and the detection limit calculated was found to be 6.324 nM for TNP. The synthesized nanocomposite provides a promising platform for the development of sensors with improved reproducibility and stability for ultra-sensitive and selective sensing of TNP.

The Selection of Sample Injection Modes and Its Effect on the Calibration Bias in S Gas Detection by Gas Chromatography (GC의 주입방식 차에 따른 고농도 악취황 성분의 검량오차 연구 : 주입부피의 고정방식 대비 주입농도의 고정방식 간 비교연구)

  • Kim Ki-Hyun;Choi YJ
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.269-274
    • /
    • 2005
  • In this work, analytical bias arising from the gas chromatographic determination of sulfur compounds was evaluated by the application of direct loop injection method to the GC/PFPD detection of four sulfur compounds including H$_{2}$S, CH$_{3}$SH, DMS, and DMDS. For the proper evaluation of analytical uncertainties involved in GC calibration, we employed two comparative techniques of calibration at fxed concentration injection (CFCI) vs calibration at fixed volume injection (CFVI) method. The results of our study indicate that CFCI method exhibits very poor sensitivity due to the matrix effect with varying injection volumes. On the other hand, as CFVI method overcomes such limitation, it can be used to obtain very accurate quantification of S compounds at their high concentration levels above a few to a few tens ppb.

Monitoring of Residual Sulfur Dioxide in Herbal Medicines Distributed at Domestic (국내 유통 한약재의 잔류이산화황 함량 모니터링)

  • Lee, Ah Reum;Jang, Seol;Kim, Tae Hee;Lee, A Yeong;Choi, Goya;Kim, Ho Kyoung
    • Korean Journal of Medicinal Crop Science
    • /
    • v.21 no.2
    • /
    • pp.124-129
    • /
    • 2013
  • This study was conducted to investigate the residual contents of sulfur dioxide ($SO_2$) in commercial medicinal herbs in Korea in 2012. Among a total of 136 samples of 16 different kinds of herbs, 86 samples (15 Kinds) were domestic, and 50 samples (14 Kinds) were imported. Sulfur dioxide in the samples was measured by a modified Monier-Williams method. Of the 136 samples, 17 samples (12.5%, 6 Kinds) failed to meet the regulations for sulfur dioxide residues of KFDA in medicinal herbs. Among 17 unsuitable samples, 7 samples (8.1%, 3 Kinds) were domestic, and 10 samples (20.0%, 6 Kinds) were imported. The highest amount of sulfur dioxide residues was 3,167.94 mg/kg (Lycii Fructus) in the domestic samples. The detection frequency of sulfur dioxide by medicinal herb parts used, Rhizoma 25.7%, Flos 20.0%. Cortex 12.5%, Radix 15.3%, Fructus 7.6%, p-value 0.011. This results will be used as a basic data for the future legislation on the quality estimation and safety of medicinal herbs.