• Title/Summary/Keyword: Supply apparatus

Search Result 125, Processing Time 0.03 seconds

Technical Considerations of Recycling Water Treatment/Supply Apparatus using Living Waste Water (생활 오배수를 이용한 중수처리 공급장치의 기술성 고찰)

  • Cho, Chung-Sik;Lee, Hee-Wan;Kim, Hong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.493-498
    • /
    • 2008
  • The several water resources are showed recently the various pollution types due to the industrialization and the disarranged district development. The living waste water, plant waste water and so are contaminated continuously and the recycling water is concerned highly to save the cost and to improve the environment as the general people. The dust and the heavy metal in the air and the acid rain are contaminating the river water and the underground water. The clean environment is on the rise to the general people and is to be the social problems. There is going to complement and repair the water supplying and fire extinguishing pipeline to save the construction cost and improve the environment in the construction facilities parts. Therefore, in this paper the recycling water treatment/supply apparatus using the living waste water is considerated technically and is raised on the practical uses.

  • PDF

A Study on the Feed Apparatus of Low Cost Automation for Circumferential Workpiece in Press Working (프레스 작업시 원주형 재료의 간이 자동공급 장치에 관한 연구)

  • 윤상건
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1992.03a
    • /
    • pp.1-10
    • /
    • 1992
  • Press is one of the most dangerous machine among the hazardous machinery. So, the apparatus of low cost automation is suggested to supply circumferential workpieces to press. And the apparatus is mocked up to apply practically.

  • PDF

A Study on the Selection Method of Parameters for Energy Saving in Pneumatic Cylinder Driving Apparatus (소비에너지 절약을 위한 공기압 실린더 구동장치의 파라미터 선정방법)

  • Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.16 no.2
    • /
    • pp.60-65
    • /
    • 2012
  • Pneumatic actuators are clean, lightweight, and can be easily serviced, whereas low energy efficiency has been considered as a critical shortcoming compared with corresponding hydraulic and electrical actuators. This study describes a new design method of pneumatic cylinder driving apparatus by lowering a supply pressure. The simulation study demonstrates that the designed system with the proposed method can operate at the smaller energy consumption state compare to the designed system with the conventional method for the specified working conditions.

A Study on Supply and Rate Policy of Midnight Power Apparatus in the Deregulation (구조개편에 따른 심야기기 보급정책과 심야요금의 변화)

  • Kim, C.S.;Rhee, C.H.;Lee, K.D.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.410-412
    • /
    • 2002
  • So far, electricity rate under the midnight hour incorporates policy consideration and maintains fixed irrespective of generation cost. Therefore, the promotion of midnight power apparatus has been rapidly increased due to increasing difference in substitute heating cost. This paper estimates the power supply cost during midnight times and analyzes the rate mechanism which can promote economic midnight power apparatus. In addition it provides the alternative on the direction of policy after the restructuring.

  • PDF

A Study on Design of Multi-Winding Transformer for Poly Silicon Production using Heat Pipe (히트파이프를 이용한 폴리실리콘 제조용 다중권선 변압기 설계에 관한 연구)

  • Lee, Chun-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.11
    • /
    • pp.1626-1630
    • /
    • 2015
  • This paper reflected the Temperature test value and compare the Computational Fluid Dynamic analysis value on particular characteristics of the multi-winding transformer's cooling apparatus equipped by heat pipe with excellent heat transfer ability on design Particularly if you look at multi-winding transformers that supply high-quality Direct current power to silicon production apparatus, heat generation due to high current supply is excessive thus, an innovative cooling apparatus is required in particular for reduced size transformer.

A study on present status and improvement of protection relay system in subway station for stable power supply (지하철 역사의 안정적 전원공급을 위한 보호시스템 검토)

  • Na, Jong-Woo;Jo, Won-Kang;Park, Dong-Seon;Yoo, Yeon-Seong;Moon, Hwa-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

A Method of Estimation of Energy Consumption according to a Supply Pressure for Pneumatic Cylinder Driving Apparatus (공급압력 변화에 의한 공기압 실린더 구동장치의 소비에너지 변화량 추정 방법)

  • Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.15-20
    • /
    • 2012
  • Pneumatic cylinder meter-out driving apparatus is used widely because it is clean, lightweight, and can be easily serviced. In this study an estimation method of energy consumption for pneumatic cylinder meter-out driving apparatus is proposed. The proposed method is derived from state equation and energy equation of air, and, the equation of motion of a moving part of a pneumatic cylinder reflecting the characteristics of the meter-out driving. The effectiveness of the proposed method is proved by simulation study and it demonstrates that the proposed method can evaluate the energy consumption quickly and easily when the parameters of the driving apparatus are changed.

Supply Chain Analysis in Public Works: The Role of Work Climate, Supervision and Organizational Learning

  • SOETJIPTO, Noer;KURNIAWAN, Gogi;SULASTRI, Sulastri;RISWANTO, Ari
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.12
    • /
    • pp.1065-1071
    • /
    • 2020
  • The study aims to analyze the supply chain role of supervision, discipline, work climate, and organizational learning on the performance of community services at the public works. This study took a sample of employees through purposive sampling technique at the Public Works Office and Bina Marga in a regency in East Java. Data through questionnaire was collected through a 5-point Likert scale model. The results show that the application of employee discipline affects the performance of public services, with a contribution of 39.7%, meaning that discipline and organizational learning are implementation factors that have an effect on public service performance. In stepwise regression analysis, the supervisory factor has a correlation with service performance, but it is less relevant, while the work climate is not relevant as a predictor variable to improve public service performance. The study revealed the importance of the supply chain policy of implementing good and clean governance and the enactment of the performance appraisal of the government apparatus established through Good Corporate Governance of the state apparatus. The findings provide a basis to encourage the public sector performance to smooth every step of supply chain management of every government project work, especially in the field of public services.

A Study on the Reaching Time of Setting Temperature with Ventilation Air (급기환기량에 따른 공조기의 설정온도 도달특성 분석 연구)

  • Kang Tae-Wook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.50-57
    • /
    • 2006
  • This study describes to analyze the cooling load characteristics for a room air conditioner as a function of supply ventilation air when an air conditioner is running An experimental apparatus consists of a test room, a room air conditioner, a humidifier, an electrical heater a supply fan and a controller The reaching time to the inside setting temperature of the room air conditioner with is evaluated theoretically and experimentally in a conditioned space cooling loads such as supply ventilation air, lighting, occupancy and infiltration. In the conditions of cooling loads for the supply ventilation air of 9.5 L/s(0.98 ACH). lights. one Person, and infiltration, the reaching time to the inside setting temperature ($27\;^{\circ}C$ dry-bulb) increases up to $35\%$ more than for no supply ventilation air condition. Theoretical modelling of the reaching time shows good agreement with experimental results.

Arc-Withstanding Characteristics with respect to the nozzle material for EHV Class Gas Circuit Breakers (초고압 가스차단기용 노즐의 재질에 따른 내아크 특성)

  • Chong, J.K.;Song, K.D.;Park, K.Y.;Song, D.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.860-863
    • /
    • 2002
  • Recently, main nozzle and inner nozzle for EHV class gas circuit breakers were made by PTFE(Poly Tetra Fluoro Ethylen) for the basic material composite. But, nowadays strengthened PTFE was demanded because the supply of electric power increased. This paper shows the research results for nozzles according to the filler materials.

  • PDF