• Title/Summary/Keyword: Supply ratio

Search Result 1,352, Processing Time 0.028 seconds

Emission characteristics of diesel engine by mixing LPG (디젤기관의 LPG 혼합에 의한 오염배출물 저감특성)

  • 장영준;전충환;이춘우
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.44-52
    • /
    • 1993
  • In this study, the characteristics of decreasing exhaust gas of diesel engine was examined in dual fuel method by using commertial LPG for automotive. LPG was supplied to engine intake port by fumigation method and flow rate was controlled by using the needle valve. LPG supply ratios were 0, 20, 30% of total fuel amount to be supplied to engine by mass base. We investigated the effect of LPG supply ratio on exhaust gas concentrations related to excess air ratio and engine load at 1600, 1800, 2000 rpm. Soot concentration decreased about 30% in proportion to the increase of the LPG supply ratio. NOx concentration decreased in proportion to the increase of the LPG than diesel only and the increase rate was higher at low engine load. BSFC(Brake specific fuel consumption) was lower in proportion to the increase of the LPG supply ratio at high engine load and to the decrease of LPG supply ratio at low engine load.

  • PDF

Parallel reservoirs system operation using NYC-Space Allocation-Rule (NYC-Space Allocation Rule을 이용한 병렬저수지 연계운영)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.533-542
    • /
    • 2005
  • In this study, an optimization technique was developed from the application of Allocation Rule. Average Allocation coefficients of the Andong and Imha dam compare constant water supply condition with vary water supply condition that are above the contribute ratio $67\%\~50\%$ the Andong dam in Rule(A)-Rule(C). In the Refill Season, Andong dam water supply contribution is higher than Imha dam at the Control point water supply. In the Allocation analysis results, Rule(A) is calculated storage ratio because Andong dam contribute to Control point larger than Imha dam which Andong dam storage is larger than Imha dam storage. Rule(B) calculated sum of the storage and inflow ratio for Andong dam and Imha dam, as Andong dam contribution is higher than Imha dam. Rule(C) calculated that sum of storage, inflow and water supply is divided average storage ratio, as the best results of the Allocation coefficients and water supply capacity. The results of storage analysis is larger vary water supply condition than constant water supply condition and the results of water supply analysis is larger vary water supply condition than constant water supply condition. Water supply deficit is decrease $30\%$ for vary water supply condition.

A study on method for improving renewable energy supply ratio for the school building applied PV system (태양광발전 시스템이 설치된 학교건물의 신재생에너지 공급비율 증가방안에 관한 연구)

  • Kim, Seok-Hyun;Lee, Yong-Ho;Hwang, Jung-Ha;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.42-49
    • /
    • 2013
  • Recently, the attention to renewable energy has increased globally because of the environmental issue and the global energy crisis. Accordingly, south korea is focused on increasing the renewable energy usage. And the government enforced a law to the public buildings to install the renewable energy facilities. In this study, the building to evaluate renewable energy consumption and supply ratio was selected. This building has 9.79% of renewable energy supply ratio by PV system. In this study, the method for improving renewable energy supply ratio was analyzed using additional PV system. And The 5 methods to increasing electricity were evaluated. The method of increase 4.24 times PV arrays area is most efficient way to increase the renewable supply ratio. The case 1, show that the increasing renewable energy supply ratio of 39.2% compared to exsiting PV system. The result of the above, consider the additional supply of renewable energy.

An Investigation of the Relationship between Revenue Water Ratio and the Operating and Maintenance Cost of Water Supply Network (상수관망 유수율과 유지관리 비용의 관계 분석)

  • Kim, Jaehee;Yoo, Kwangtae;Jun, Hwandon;Jang, Jaesun
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.202-212
    • /
    • 2012
  • Due to the deterioration of water supply network and the deficiency of raw water, the water utility of local governments have performed various projects to improve their revenue water ratio. However, it is very difficult to estimate the cost for maintaining the revenue water ratio at higher level after completing the project, because local governments have different conditions affecting the operating and maintenance cost of water supply network. The purpose of this study is to present a procedure to estimate the operating and maintenance cost required to maintain the target revenue water ratio of the water supply network. For this purpose, we estimated the cost used only for operation and maintenance of water supply network of 164 local governments with the aid of K-Mean Clustering Analysis and the data from 40 representative local governments. Then, the regression analysis was performed to find relationship between revenue water ratio and the operating and maintenance cost with two different data sets generated by two classification methods; the first method classifies the local governments by means of k-means clustering, and the other classifies the local governments according to the index standardized by the operating and maintenance cost per unit length of water mains per revenue water ratio. The results shows that the method based on the index standardized by the cost and revenue water ratio of each government produces more reliable results for finding regression equations between revenue water ratio and the operating and maintenance cost only for water supply network. The estimated regression equations for each group can be used to estimate the cost required to keep the target revenue water ratio of the local government.

The Analysis on the Correlationship for Rousing Demands and Water Supply Ratio (주택수요 예측을 위한 주택량과 상수도보급률의 상관성 분석)

  • Yang Seung-Won;Park Keun-Joon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.2 s.24
    • /
    • pp.61-68
    • /
    • 2005
  • The analysis described in this paper indicate the existence of a correlationship for housing demand and water supply ratio. Using subjective statistical data for the trend of population on regional area, water supply ratio and the number of households, the paper examines the correlationship of forecasting factors for apartments in the ways in which the tendency of demands for apartments and water supply ratio have been analyzed within small and mediumsized city. Differences in the correlationship on the several scale of a city are also taken into account in the analysis. The summary table of the tendency for housing supplies, population and water supply ratio on each scale of a city was generated using data from LAIB. This study attempted to address certain factors that are measurable within a specified paradigm, in order to investigate the extent to which the expectation of apartment supplies can be estimated from the correlationship of water supply ratio. Therefore, it can be suggested that the limited scale of a city are set to maintain the correlationship for housing demands and water supply ratio.

Characteristics of Fluid Supply in Discontinuous Wheel Grinding (단속연삭의 유제공급 특성)

  • Kwak, Yong-Gil;Hong, Sun-Ik;Song, Ji-Bok;Koo, Yang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.857-861
    • /
    • 1997
  • In discontinuous wheel grinding, temperature is different form conventional grinding. The characteristics of discontinuous grinding with respect to various slotted wheel were compared with those of general grinding. Thermal conditions vary with intermittent ratio, direction of fluid supply for discontinous wheel. According to three direction of grinding fluid supply and intermittent ratio,temperature and surface roughness were analyzed.

  • PDF

Evaluating the Supply Plan of Public Rental Housing under the Lee Myung-bak Government -focused on housing needs of tenants in private rental housing- (보금자리 임대주택 공급목표의 타당성 평가 -민간주택 임차가구의 주거소요 분석을 중심으로-)

  • Nam, Won-Seok
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.187-192
    • /
    • 2011
  • The purpose of this study is to evaluate the supply plan of public rental housing under the Lee Myung-bak government. According to the supply plan, the government will supply public rental housings by 80,000 unit every year from 2009 to 2018, and achieve 12% as stock ratio in 2018. To evaluate the supply plan, this study analyzed housing needs of tenants in private rental housing by using the raw data of Korea Welfare Panel Survey(2008). The results are as follows: (1) It is difficult for the supply plan to meet the housing needs of tenants in private rental housing. (2) The link between supply plan and stock ratio target is weak. (3) To meet the housing needs, it is necessary to supply public rental housings by 107,000 unit every year for 10 years, and, in this case, the stock ratio will be 10% in 2018. In conclusion, this study proposed that the supply plan of public rental housing should be redesigned.

  • PDF

Evaluating the Supply Plan of Public Rental Housing under the Lee Myung-bak Government - Focused on Housing Needs of Tenants in Private Rental Housing - (보금자리 임대주택 공급목표의 타당성 평가 - 민간주택 임차가구의 주거소요 분석을 중심으로 -)

  • Nam, Won-Seok
    • Journal of the Korean housing association
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The purpose of this study is to evaluate the supply plan of public rental housing under the Lee Myung-bak government. According to the supply plan, the government will supply public rental housings by 80,000 unit every year from 2009 to 2018, and achieve 12% as stock ratio in 2018. To evaluate the supply plan, this study analyzed housing needs of tenants in private rental housing by using the raw data of Korea Welfare Panel Survey (2008). The results are as follows: (1) It is difficult for the supply plan to meet the housing needs of tenants in private rental housing. (2) The link between supply plan and stock ratio target is weak. (3) To meet the housing needs, it is necessary to supply public rental housings by 107,000 unit every year for 10 years, and, in this case, the stock ratio will be 10% in 2018. In conclusion, this study proposed that the supply plan of public rental housing should be redesigned.

Investigation of Impact of Revenue Sharing Contract on Performance of Two-Stage Supply Chain System

  • RYU, Chungsuk
    • Journal of Distribution Science
    • /
    • v.20 no.6
    • /
    • pp.125-135
    • /
    • 2022
  • Purpose: The revenue sharing contract has been used in various industries and it is expected to coordinate the individual companies' operations in a way to improve the whole supply chain performance. This study evaluates the performance of the revenue sharing contract to find out whether this contract achieves its original goal, the supply chain coordination. Research design, data, and methodology: The profit optimization models are developed to represent two stage supply chain system with a supplier and a buyer. By using the numerical examples of the proposed mathematical models, this study examines whether this supply chain contract coordinates the supply chain system. Results: The numerical examples show that the revenue sharing contract does not make the same supply chain profit as the centralized system does. With the proper combination of the wholesale price discount rate and revenue share ratio, both manufacturer and retailer can obtain increased profits from the revenue sharing contract. Conclusions: The outcomes of the numerical analysis imply that the revenue sharing certainly improves the supply chain performance but it does not fully coordinate the supply chain system. By controlling the wholesale price and revenue share ratio, every supply chain member can be beneficiaries of this supply chain contract.

Operation Rule Curve for Reservoir with Low Areal Ratio of Watershed to Downstream Paddy Field (유역배율이 작은 저수지의 이수관리방법)

  • Noh, Jae-Kyoung
    • KCID journal
    • /
    • v.18 no.1
    • /
    • pp.68-80
    • /
    • 2011
  • To provide a operation rule curve for reservoir with low ratio of watershed area to paddy field area, Duckyong reservoir with watershed area of $15.8km^2$ and paddy field area of 1,071ha was selected, in which 4 meters are being heightened and full water levels will be increased from EL.26.0m to EL.30.0m, total water storages from 365.6M $m^3$ to 708.0M $m^3$. There was no operation rule curve that satisfied over 90% reliability of water supply in reservoir with watershed area of 1.48 times of paddy field area. The differences between observed and simulated reservoir daily water storages were minimized to determine parameters for simulating reservoir inflow in case of paddy field area of 550ha from 1991 to 2010. A operation rule curve was drawn to have a maximum storage with total water storage, which was in paddy field area of 700ha with ratio of 2.3 between watershed area and paddy field area. This case showed that annual irrigation water supply was 668M $m^3$ and instream flow of 57M $m^3$, water supply reliability of 55.6% in normal operation, and annual irrigation water supply was 605M $m^3$ and instream flow of 38M $m^3$, water supply reliability of 95.6% in withdrawal limited operation. Water supply reliabilities showed 35.6% without flood regulation and 17.8% with flood regulation in existing reservoir before heightening.

  • PDF