• Title/Summary/Keyword: Surface hardness

Search Result 2,493, Processing Time 0.039 seconds

HARDNESS CHANGE OF LIGHT-ACTIVATED GLASS IONMER CEMENT WITH THICKNESS AND TIME (광경화형 글래스아이오노머 시멘트의 두께 및 시간경과에 따른 경도의 변화)

  • Lee, Kyoung-Jin;Oh, Won-Mann;Kim, Sun-Hun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.303-315
    • /
    • 1995
  • An adequate and homogeneous cure of light-activated restroative material is very important for improvement of marginal adaptation and prevention of marginal leakage, secondary caries and pulpal irritation as well as expressing natural physical property of that material. The purpose of this study was to evaluate the change of surface hardness and cure uniformity of light-activated glass ionomer cements. Restorative(Fuji II LC, Vitremer) and lining(Baseline VLC, Vitrebond) light-activated glass ionomer cements were investigated for this study. The surface hardness of the top and bottom surfaces and cure uniformity of each 1mm, 1.5mm, 2mm, 2.5mm & 3mm in the thickness of specimen were measured immediately, at 1 hour, 24 hours and 1 week after light activation. The surface hardness change and cure uniformity of all the specimens were measured by Knoop hardness tester. The results were as follows. 1. The surface hardness of top and bottom surfaces in all groups increased with time(p<0.01). 2. Both top and bottom surfaces hardness of Vitrebond group measured immediately after light-activation were significantly lower than those of the other groups(p<0.01). 3. The surface hardness of top and bottom surfaces of restorative light -activated glass ionomer cements was higher than those of lining materials at 1 week(p<0.10). 4. Surface hardness of Vitremer group decreased as the specimen thickness increased, except top and bottom surfaces hardness of the specimen at 1 week(p<0.01). There was no significant difference in the surface hardness of Fuji II LC with changes in the thickness except bottom surface hardness of specimen at 24 hours and 1 week (p>0.05). 5. Surface hardness of Vitrebond group significantly decreased as the specimen thickness increased(p<0.01). There was no significant difference in the surface hardness of Baseline VLC group with changes in the thickness except bottom surface hardness of specimen measured immediately after light -activation(p>0.05). 6. The hardness ratio of top against bottom surface in all groups decreased with time(p<0.05). 7. There was no significant difference in the hardness ratio of top against bottom surface with changes of the thickness except Vitrebond group, 24 hours and 1 week of Vitremer group and 1 week of Baseline VLC group (p>0.05). These results suggest that surface hardness of restorative ligh-activated glass ionomer cements were highter than those of lining light-activated materials. In all groups, the surface hardness and cure uniformity continuously increased with time.

  • PDF

Surface hardness measurement of NiP-plated AA7050

  • Moon, Sungmo;Kim, Juseok
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.4
    • /
    • pp.171-177
    • /
    • 2021
  • This paper is concerned with the surface hardness measurement of NiP-coated AA7050 using different loads from 10 to 100 g. The surface hardness was observed to increase from 180 to 600 Hv with increasing NiP layer thickness, depending on the load applied for indentation. When NiP coating thickness is thinner than 2 ㎛, the surface hardness of NiP-coated AA7050 was mainly determined by AA7050 substrate, while it was significantly increased by NiP coating layer when NiP coating thickness is thicker than 2 ㎛. Hardness of AA7050 substrate itself was not dependent on the applied load but the hardness of NiP-coated AA7050 was largely influenced by the load applied for indentation. The largest difference of hardness between 10 g and 100g of applied loads, was obtained at the NiP thickness of about 8 ㎛ above which the measured hardness at 10 g reached a maximum value of about 600 Hv. It was also observed that indentation-induced plastic deformation next to the indented zone occurs when NiP layer is 5.64 times thicker than the depth of impression formed by indentation.

Application of Friction Stir Process to Improve Surface Reliability of Light Weight Magnesium Alloy (경량 마그네슘 합금의 표면 신뢰성 향상을 위한 마찰교반공정의 적용)

  • Gil, Ung-Chan;Kim, Jae-Yeon;Hyun, Chang-Young
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.155-161
    • /
    • 2016
  • Purpose: Purpose of this study is to analyze the effect of particle size as well as number of pass on surface microstructure and hardness of SiC(p)/AZ31 surface composite fabricated by friction stir process (FSP). Method: SiC(p)/AZ31 surface composite containing different size of SiC particle (i. e., $2{\mu}m$ and $8{\mu}m$) was fabricated by multi-pass FSP. Microstructure was observed by scanning electron microscope and surface hardness was determined by Vickers hardness tester. Results: For all the FSPed specimens with and without hardening particles, grain size was refined due to dynamic recrystallization behavior. Surface hardness was observed to increase with decreasing particle size in the composite layer. Increasing number of FSP pass was effective for homogeneous distribution of the hardening particles and for resulting increase in surface hardness. Conclusion: FSP was effective to modify surface microstructure for improving surface hardness of SiC/AZ31 composite.

Novel Methods for Measuring the Surface Hardness of Anodic Oxide Films on Aluminum Alloy (알루미늄 합금 양극산화피막의 표면경도 측정법)

  • Moon, Sungmo
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.1
    • /
    • pp.36-42
    • /
    • 2020
  • In this study, two novel methods to measure the surface hardness of anodic oxide films on aluminum alloys are reported. The first method is to impregnate oil-based ink into pores in the anodic oxide film and then to clean the ink on the surface using ethanol, resulting in an impregnation of inks only inside of the pores in anodic oxide film. The second method is to coat the anodic oxide film surface with thin Au layer less than 0.1 ?. Both the ink-impregnating method and Au-coating method provided clear indentation marks on the anodic oxide film surface when it was indented using a pyramidal-diamond penetrator. Thus, Vickers hardness of anodic oxide films on aluminium alloy could be measured successfully and precisely from the anodic film surface. In addition, advantages and disadvantages of the ink-impregnating method and Au-coating method for the measurement of surface hardness of anodic oxide films are discussed.

The Analysis for Surface Hardening by Repeated Sliding Contact (반복 미끄럼 접촉에 의한 표면층의 경화에 대한 해석)

  • 박준목;김석삼
    • Tribology and Lubricants
    • /
    • v.13 no.4
    • /
    • pp.71-78
    • /
    • 1997
  • Wear is affected by numerous factors-contact load, sliding velocity and distance, friction coefficient, material properties and environmental conditions. Among these wear factors, surface hardness is one of very important factors to determine wear. But surface hardness is varied by work hardening during repeated sliding contact. In this reason wear rate is increased or decreased with varying surface hardness, and transition of wear mechanism is happened. In this study, the surface hardening by accumulating residual stress was analyzed by considering the repeated sliding Hertzian contact model. The results showed that surface hardness was increased with increasing contact load, friction coefficient and contact number. And the depth of hardening layer, plastic layer and elastic layer depended upon contact load and number, but they didn't depend upon friction coefficient. The predicted surface hardness was about 1.5-1.8 times as hard as the material.

A Study on the Surface Roughness Influenced by SM45C Hardness in High Frequency Induction Hardening (고주파열처리에 의한 SM45C 경도가 가공 표면 품위에 미치는 영향에 관한 연구)

  • Kim, W.I.;Heo, S.J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 1993
  • In this paper, the surface roughness influenced by Sm45C hardness in high frequency induction hardening and mechanical characteristics for the changed Hv 598 part and the unchanged hardness Hv 223 part by use of cermet and ceramic cutting tools was experimentally examined. Finally, we could be had some important results by processing surface roughness on cutting conditions such as cutting speed, feed rate, depth of cut and changes of tool nose radius. The results are summarized as follows. 1. In case of the same cutting condition, the hardness of workpiece was high and acquired the best processing surface roughness when the radius of the tool nose had 0.8 mm and feed rate was 0.04 mm/rev. 2. In case of the hardness of workpiece, though the cutting speed didn't have an effect on processing surface roughness, the less feed rate and the more processing surface roughness improved. On the other hand, the low inside the hardness of workpiece, the more cutting speed and the more feed rate increase, the processing surface of roughness improved. 3. Regardless of the hardness of workpiece, the change of the cutting depth didn't have great effect on the surface roughness. 4. On cutting the high surface hardness part with cutting tools of cermet and ceramic, it can be acquired the higher processing surface roughness because it hadn't been taken effect on cutting speed, In case of the cutting process of the low inside hardness part the two cutting tools have acquired the similar processing surface roughness.

  • PDF

Effect of surface hardness on piston wear in the oil hydraulic piston pump (유압 피스톤 펌프의 피스톤 마모에 대한 표면경도의 영향)

  • 김종기;정재연
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.340-345
    • /
    • 2001
  • Surface hardness is one of the major sources on wear in the oil hydraulic axial piston pump. To increase the performance of the oil hydraulic axial piston pump, it is need to know the surface layer characteristics in the sliding contact parts of them. This paper reports an experimental study on surface treatment characteristics in the piston of the oil hydraulic axial piston pump. We investigated surface wear with not only surface hardness and surface roughness but also material of the piston. We obviously observed that the surface hardness of piston in the oil hydraulic axial piston pump plays an important role to high power density and remain long life.

  • PDF

Abrasion Resistance and Surface Hardness of Gold Plated Carbonized Board (도금처리 탄화보드의 내마모성 및 표면경도)

  • Hwang, Sung-Wook;Park, Sang-Bum;Lee, Won-Hee
    • Journal of the Korea Furniture Society
    • /
    • v.23 no.4
    • /
    • pp.435-439
    • /
    • 2012
  • This research was performed to evaluate surface performance of gold plated carbonized board. After the carbonization at $850^{\circ}C$, volume, weight, and density decreased by 65.25%, 71.35% and 17.64%, respectively. Abrasion resistance and surface hardness of non-carbonized board exhibited the highest values of 0.093 g/100 revolution and 26.43 N/$mm^2$, respectively. Gold plated carbonized board showed intermediate values, 0.587 g/100 revolution of abrasion resistance and 24.35 N/$mm^2$ of surface hardness. Carbonized board showed the lowest values, 0.863 g of abrasion resistance and 21.50 N/$mm^2$, of surface hardness. These results were thought to reflect propertional relationship between abrasion resistance and surface hardness. Abrasion resistance and surface hardness of carbonized board appeared able to be improved by surface treatment such as plating.

  • PDF

Experimental Studies on the Improving Surface Hardness of Dental Stone (치과용(齒科用) 경석고(硬石膏) 의 표면경도(表面硬度) 강화(强化)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.23-27
    • /
    • 1969
  • The purpose of this studies is to determine the surface hardness of dental stone and to investigate the methods which increase the surface hardness of dental stone using the dissolved solution of various synthetic resin, the obtained results of hardness value calculated Rockwell Hardness Number by means of Rockwell Hardness Tester. 1) In this experiment, 10% polystyrene dissolved in 100cc amylacetate is excellent solution which provides the surface hardness of dental stone after setting of specimen, and there is no effective way that stone specimen is immersed into polystyrene in amylacetate, polystyrene in benzene and polystyrene in butylacetate above 1 hour. 2) When the stone specimen is immersed into acrylic resin in benzene and melamin resin in amylacetate at least 1 hour to 3 hours, the hardening effect of stone surface is valuable. 3) The stone specimen immersing into urea resin in butylacetate, the surface hardness of the stone specimen decreased within 1 hour, but increased after 3 houre. 4) For the separating medium, the easyfoil is superior to the olive oil in the aspect of improving the hardening effect of the immersed specimen.

  • PDF

Surface Hardness and Water Repellet of Earth Paint (흙페인트의 적절한 사용을 위한 표면경도 및 발수성에 관한 연구)

  • Hawng, Hey-Zoo;Roh, Tea-Hak;Lee, Jin-Sil
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.83-88
    • /
    • 2016
  • Purpose : This study aimed to verify the surface hardness and water repellency of earth paint manufactured with earth, a natural material, and provide the results as basic data for paint made with natural materials. Method : After presenting the accurate manufacturing methods for basic materials for paint, the authors conducted and analyzed experiments to evaluate surface hardness and water repellency, fundamental performance indicators for paint, based on different mixture ratios. From the results of the experiment to assess the surface hardness of flour-based earth paint, we observed high surface hardness only after painting the specimen three times. Since potato starch-based earth paint has higher viscosity than its flour-based counterpart, the former did not paint well on the first occasion, resulting in low surface hardness. After painting two or more times, however, it was observed to have higher surface hardness than flour-based earth paint. Result : It was found that at least three iterations of painting was required to obtain high surface hardness of potato starch-based earth paint. Furthermore, the results of the water resistance experiment of earth paint suggest that the use of environment-friendly finishing materials coupled with boiled linseed oil will mitigate the drawbacks of earth paint. The experiment with one-year-old specimens also demonstrated similar water repellent characteristics, which indicates that the performance will improve once the paint has dried for a sufficient period of time.