• Title/Summary/Keyword: Switching method

Search Result 2,706, Processing Time 0.027 seconds

Automatic Protection Switching Schemesfor Network Survivability in ATM-PON Networks (ATM-PON망에서 망 생존성을 위한 자동보호절체)

  • 김영구
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.9A
    • /
    • pp.1441-1451
    • /
    • 2000
  • There are two types of protection switching : a) automatic switching and b) forced switching. The switching mechanism is generally realised by OAM functions, therefore, the required OAM information field should be reserved in the PLOAM cells. This paper proposes an unidirectional and a bidirectional protection switching method and potential advantages. The unidirectional protection switching method can be faster than the bidirectional method because the unidirectional method does not require an APS protocol for protection switching. The bidirectional protection switching method uses APS K1 byte and K2 byte, which is included in octets of a PST message through downstream or upstream PLOAM cells, for protection switching. As making comparisons between the unidirectional and the bidirectional protection. switching method, this paper proposes an effective constructing method for ATM-PON network.

  • PDF

A New Switching Method for Reducing switch loss of Single-phase three-level NPC inverter (스위치 손실 감소를 위한 단상 3레벨 NPC 인버터의 새로운 스위칭 방법)

  • Lee, Seung-Joo;Lee, June-Seok;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.268-275
    • /
    • 2015
  • This paper proposes a method of switching to improve power loss for the single-phase three-level NPC inverter. The conventional switching methods, which are called as the bipolar and unipolar switching methods, are used for single phase inverters using three-level topology. However, these switching method have disadvantage in the power loss. Because all of the switch are operated. To reduce the power loss of the three-level NPC inverter, clamp switching method is introduced in this paper. This way, one of the lag is fixed that switching loss is reduced. This paper analyzes and compares power losses of unipolar method and clamp method. The validity of the power loss analysis is verified through the simulation and experimental results.

Implement of Constant-Frequency-Controled Zero-Voltage-Switching Converter-fed DC Motor Drive for Low Power Loss (직류 전동기의 저손실 구동을 위한 일정 주파수 제어형 영전압 스위칭 변환기의 구현)

  • Ko, Moon-Ju;Park, Jin-Hong;Han, Wan-Ok;Lee, Sung-Paik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2148-2150
    • /
    • 1998
  • This paper proposes a constant frequency controlled zero voltage switching method that can reduce switching losses caused by emf on inductance in DC motor. The zero voltage switching method is used more than a zero current switching method because of reducing switching losses by capacitance of depletion region of MOSFET. To simplify the controller circuit, we propose constant frequency controlled zero voltage switching method in the paper. The control method is more stable than a variable frequency control method because it can optimize bandwidth of a closed-loop and reactances. Therefore, we construct a constant frequency controlled zero voltage switching converter and improve zero switching losses in high switching frequency. In the process, we can control low-losses in full range on variable voltage and load. We simulate the proposed converter with P-SPICE and compare results obtained through the experiment.

  • PDF

Analysis of Oscillation Modes Occurred by ON/OFF Time Intervals of Switching Equipments by the RCf Method (RCF 해석법을 사용한 스위칭 설비의 ON/OFF 시간간격에 의한 진동모드 해석)

  • Kim, Deok-Young;Dong, Moo-Hwan;Lee, Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.1
    • /
    • pp.13-17
    • /
    • 2006
  • In this paper, the RCF(Resistive Companion Form) analysis method which is used to analyze small signal stability problems of non-continuous systems including switching devices. The RCF analysis method is mathematically rigorous and computes eigenvalue of the system periodic transition matrix based on discrete system analysis method. As an effect of switching operations, the eigenvalues of the systems are changed and newly unstable oscillation modes may be occurred. As an illustrating example, the oscillation modes of the system with different switching time intervals are computed exactly by the RCF analysis method and the results show that ON/OFF time intervals of switching equipments are important factors to make the system stable or unstable. This result shows that the RCF analysis method is very powerful to analyze small signal stability problems of power systems including switching devices such as FACTS equipments.

Newton Method MPPT Control and Soft Switching Converter Simulation for Improving the Efficiency of PV System (태양광발전 시스템의 효율 개선을 위한 Newton Method MPPT제어 및 소프트 스위칭 컨버터 시뮬레이션)

  • Jang, In-Hyeok;Lee, Kang-Yeon;Choi, Youn-Ok;Cho, Geum-Bae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.246-252
    • /
    • 2011
  • In this paper proposes the soft-switching boost converter and MPPT control for improving the efficiency of PV system. The proposed converter designed H-bridge auxiliary resonant circuit. By this circuit, all of the switching devices perform the soft switching under the zero voltage and zero current condition. Therefore the periodic switching losses can be decreased at turn on, off. The soft switching boost converter designs for 1.5[kW] solar module of the power conversion. Thus, this soft switching boost converter is simulated by MATLAB simulation using Newton-Method algorithm. As a result, Proposed Soft Switching Converter compared to a typical boost converter switching loss was reduced about 61%. And the overall system efficiency was verified to increase about 3.3%.

Reducing Switching Losses in Indirect Matrix Converter Drives: Discontinuous PWM Method

  • Bak, Yeongsu;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1325-1335
    • /
    • 2018
  • This paper presents a discontinuous pulse width modulation (DPWM) method to reduce switching losses in an indirect matrix converter (IMC) drive. The IMC has a number of power semiconductor switches. In other words, it consists of a rectifier stage and an inverter stage for AC/AC power conversion, which are composed of 12 and 6 switching devices, respectively. Therefore, the switching devices of the IMC suffer from high switching losses in the IMC drives. Various topologies to reduce switching losses have been studied by eliminating a number of switches from the rectifier stage. In this study, in contrast to prior research, a DPWM method is presented to reduce the switching losses of the inverter stage. The effectiveness of the proposed method to reduce switching losses in IMC drives is verified by simulations and experimental results.

Discontinuous PWM Scheme for Switching Losses Reduction in Modular Multilevel Converters

  • Jeong, Min-Gyo;Kim, Seok-Min;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1490-1499
    • /
    • 2017
  • The modular multilevel converter (MMC) is generally considered to be a promising topology for medium-voltage and high-voltage applications. However, in order to apply it to high-power applications, a huge number of switching devices is essential. The numerous switching devices lead to considerable switching losses, high cost and a larger heat sink for each of the switching device. In order to reduce the switching losses of a MMC, this paper analyzes the performance of the conventional discontinuous pulse-width modulation (DPWM) method and its efficiency. In addition, it proposes a modified novel DPWM method for advanced switching losses reduction. The novel DPWM scheme includes an additional rotation method for voltage-balancing and power distribution among sub modules (SMs). Simulation and experimental results verify the effectiveness and performance of the proposed modulation method in terms of its switching losses reduction capability.

An Indoor Positioning System Using Time-Synchronized Switching GPS Repeater (시각동기 스위칭 GPS 중계기를 이용한 실내측위 시스템)

  • Im Sung-Hyuck;Jee Gyu-In
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.8
    • /
    • pp.789-797
    • /
    • 2006
  • A new method for the GPS repeater based indoor positioning is proposed and its feasibility is verified by experiments in previous paper. But the problems how can identify switching GPS repeater's ID and when switching will be occurred are remained. To solve the problem faced with, we propose the time synchronized switching GPS repeater and the methods of the detection of switching time and the estimation of TDOA. First, switching GPS repeater retransmits the signals synchronized on GPS time, sequentially. Always, first switching time is synchronized with 1 PPS. Second, we formulate the detection of switching time and the estimation of TDOA and propose the various methods. No method is existed absolutely superior to others in any conditions but the method is existed superior to others in specific condition. Finally, feasibility of indoor positioning using time-synchronized switching GPS repeater is evaluated through experiments in anechoic chamber and general environment with multipath.

Turn-on Loss Reduction for High Voltage Power Stack Using Active Gate Driving Method

  • Kim, Jin-Hong;Park, Joon Sung;Gu, Bon-Gwan;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.632-642
    • /
    • 2017
  • This paper presents an improved approach towards reducing the switching loss of insulated gate bipolar transistors (IGBTs) for a medium-capacity-class power conditioning system (PCS). In order to improve the switching performance, the switching operation is analyzed, and based on this analysis, an improved switching method that reduces the switching time and switching loss is proposed. Compared to a conventional gate drive scheme, the switching loss, switching time, and delay are improved in the proposed gate driving method. The performance of the proposed gate driving method is verified through several experiments.

The Study on High-Frequency Switching Drive Method Using IGBT For Non-Magnetic Induction Heating System (비자성 유도가영시스템을 위한 IGBT를 이용한 고속스위칭 구동에 관한 연구)

  • 김정태;권경안;정윤철;박병욱
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.24-26
    • /
    • 1998
  • A new high frequency switching drive method using IGBT is proposed for non-magnetic induction heating system. Using this method, the switching and conduction losses of the switching devices can be reduced. In addition, since IGBT cosl is lower than MOS-FET one, the system cosl can be remarkably pared down. The prototype induction heating system with 1.2㎾ power consumption is builted and tested to verify the operation of the proposed high frequency switching drive method.

  • PDF