Least Square Method: A Novel Approach to Determine Symmetrical Components of Power System

  • Rehman, Bilawal;Liu, Chongru;Wang, Lili
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.39-44
    • /
    • 2017
  • This paper proposes a novel approach to determine symmetrical components of power system by applying method of least squares in time domain. For the modern power system stability, clearance of faults on high voltage transmission lines in zero response time is crucial and important. Symmetrical components have a great attention since last century. They have been found an effective tool for the analysis of symmetrical and unsymmetrical faults in power system. Moreover, magnitude of symmetrical components are also used as a caution about faults in system. With rapid changes in technology, Microprocessor assumed to be fastest machine of the modern era. Hence microprocessor based techniques were developed and implemented for last few decades. The proposed technique apply least square method in the computation of symmetrical components which is suitable as an application in microprocessor based monitoring and controlling power system in order to avoid cascading failures. Simulation of proposed model is carried out in MATLAB/SIMULINK and all results exploit the validity of model.

A New Distribution System Power Flow Method Using Symmetrical Components (대칭성분을 이용한 3상 배전계통 조류계산 기법)

  • Choe, Jeong-Hwan;Jeong, Seong-Il;Park, Je-Yeong;Kim, Gwang-Ho;Kim, Jae-Eon;Park, Jong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.15-22
    • /
    • 2002
  • This paper proposes a new power flow method for distribution system analysis by modifying the conventional back/forward sweep method using symmetrical components. Since the proposed method backward and forward sweeps with the variables expressed by symmetrical components, this method reduces computation time for matrix calculations; therefore, it is able to reduce the computational burden for real-time distribution network analysis. The proposed method was also developed to effectively analyze the unbalanced distribution system installing AVR(Auto Voltage Regulator), shunt capacitors. The proposed algorithm was compared with the conventional Back/forward Sweep method by applying both methods to three phase unbalanced distribution system of IEEE 123-bus model, and the test results showed that the proposed method would outperformed the conventional method in real-time distribution system analysis.

A Study on the Digital Relaying Techniques by Real-Time Symmetrical Components of Power System (전력계통의 실시간 대칭성분을 이용한 거리계전 기법에 관한 연구)

  • 신명철;김철환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.10
    • /
    • pp.695-702
    • /
    • 1987
  • Nowadays as the power systems have been more complicated and have grown to ultra high voltage, it requires a accurate and high speed relaying scheme to improve the reliability and stability of power systems for a harmonious power supplying. For this purpose voltage and current have to be measured at the location of the protective device and the short circuit impedance must be determined. This paper presents the application methods and some results of digital distance relaying scheme which is based upon the theouy of real-time symmetrical components. Usually the symmetrical component have been used to solve the transient systems as well as the steady state systems under unbalanced systems. But, real-time symmetrical component frequently have not been applied to on-line control region of the large power system. We have tried to apply this method to deal with the various type of faults on artificial transmission line. And experimental results demonstrate the validity of the proposed techniques. Therefore, this study is expected that it is contributed to improve the reliability of power supplying, searching for the fault location rapidly and exactly in power system.

  • PDF

Fast Extraction of Symmetrical Components from Distorted Three-Phase Signals Based on Asynchronous-Rotational Reference Frame

  • Hao, Tianqu;Gao, Feng;Xu, Tao
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.1045-1053
    • /
    • 2019
  • A symmetrical component decomposition scheme utilizing the characteristics of the asynchronous rotational reference frame transformation is proposed in this paper for the extraction of the positive and negative sequence components of distorted three-phase grid voltages. The undesired frequency component can be removed using a specially designed series coordinate transformation and half-cycle delays, where the delay can be controlled by adjusting the frequency of the rotating reference frame. The extracted symmetrical component can then be compensated based on the applied coordinated transformation. The dynamic response of the proposed algorithm is improved when compared to that of conventional methods. The effectiveness of the proposed algorithm is verified by simulation and experimental results.

A Study on the Digital Distance Relaying Techniques Using Kalman Filtering (칼만필터링에 의한 디지털 거리계전 기법에 관한 연구)

  • 김철환;박남옥;신명철
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.3
    • /
    • pp.219-226
    • /
    • 1992
  • In this study, Kalman filtering theory is applied to the estimation of symmetrical components from fault voltage and current signal when it comes to faults with the power system. An algorithm for estimating fault location accurately and quickly by calculating the symmetrical components from the extracted fundamental voltage phasor and current phasor is presented. Also, to confirm the validity of digital distance relaying techniques using Kalman filtering, the experimental results obtained by using the digital simulation of power system is shown.

  • PDF

A Study on the Wall Components of Sarang-taechong in the Upper Class houses of Chosun Dynasty (조선시대 상류주택 사랑대청의 실내입면구성요소에 관한 연구)

  • 오혜경;홍이경
    • Journal of Families and Better Life
    • /
    • v.18 no.2
    • /
    • pp.191-202
    • /
    • 2000
  • The purpose of this study was to clarify the wall components of Sarang-taechong in the upper class houses of Chosun dynasty. Physical trace method was used for this study. The samples were taken from the Sarang-taechong of 6 traditional Korean houses; Yunkyungdang, the ancient Chusa estate, Sunkyojang, Chunghyodang, Yangjindant, Unjorn. The makor findings were summarized as follows; 1) The common components of each wall were pillars, sanginbangs(upper horizontal beams), hainbangs (lower horizontal beams), door and windows. Changbangs(wood eave pieces that suported decoration blocks), changyos(a pice of wood fitted between the tops of pillars and upper tori cross beams), and morums(the top wainscot board laid horizontally between the bottom beam and the bottom portion of a window frame) were additional. 2) The composition of every south wall was symmetrical and the other threes were mixed symmetrical and asymmetrical. 3) The image of wall was classified-fine, strong, and modera e, according to the symmetry or asymmetry of wall composition, the width of each components, the kind of window.

  • PDF

A Study on the Optimal Method for Mal-function of Re-closer at the Distribution Feeders Interconnected with PV Systems (태양광발전이 연계된 배전계통의 보호기기 오동작에 대한 최적 운용방안에 관한 연구)

  • Kim, Chan-Hyeok;Park, Hyeon-Seok;Rho, Dea-Seok;Shin, Chang-Hoon;Yoon, Gi-Gab
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1512-1518
    • /
    • 2009
  • Recently, new dispersed power sources such as photovoltaics, wind power, fuel cell etc. are energetically interconnected and operated in the distribution systems, as one of the national projects for alternative energy. This paper deals with the optimal countermeasures for the mal-function of protective devices at primary feeder in distribution systems when new power sources like photovoltaic (PV) systems are interconnected, based on the symmetrical components of short circuit studies. When new power sources are considered to be interconnected to distribution systems, bi-directional power flow and interconnection transformer connection of new power sources may cause the operation problems of protective devices (mainly re-closer), since new power sources can change typical characteristics of distribution systems. Therefore, this paper shows an analysis skill of the mal-functional mechanism of protective relay and proposes the optimal solution for the mal-function problem using the symmetrical components of fault analysis. And, this paper also shows the effectiveness of proposed method by the simulation at the field distribution systems.

A Study on the Fuzzy-based Fault-type Detection Using Symmetrical Component (대칭성분에 의한 퍼지형 고장형태판별에 관한 연구)

  • Park, C.W.;Jeon, B.J.;Shin, M.C.;Lee, B.K.;Yun, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.857-860
    • /
    • 1997
  • This paper is on the application of fuzzy for fault-type approach using symmetrical components method. To evaluate performance of the proposed technique, we have been tested using a relaying signals obtained from EMTP simulation package.

  • PDF

Phase Selection Algorithm Symmetrical Components for Transmission Line Protection (대칭분 전류를 이용한 송전선로 보호용 고장상 선택 알고리즘)

  • Lee, Seung-Jae;Lee, Myoung-Soo;Lee, Jae-Gyu;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.22-24
    • /
    • 2001
  • This paper presents a fault phase selection algorithm for transmission line protection by means of the symmetrical components. Accurate fault phase selection is necessary for collect functioning of transmission line relaying, particularly in Extra High Voltage (EHV) networks. The conventional phase selection algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to abstract only fault current since we can not know the time which a fault occurs. The proposed algorithm can select the accurately fault phase using fault current contained pre-fault current.

  • PDF

Advanced aerostatic stability analysis of suspension bridges

  • Xiao, Ru-Cheng;Cheng, Jin
    • Wind and Structures
    • /
    • v.7 no.1
    • /
    • pp.55-70
    • /
    • 2004
  • Aerostatic instability of a suspension bridge may suddenly appears when the deformed shape of the structure produces an increase in the value of the three components of displacement-dependent wind loads distributed in the structure. This paper investigates the aerostatic stability of suspension bridges using an advanced nonlinear method based on the concept of limit point instability. Particular attention is devoted to aerostatic stability analysis of symmetrical suspension bridges. A long-span symmetrical suspension bridge (Hu Men Bridge) with a main span of 888 m is chosen for analysis. It is found that the initial configuration (symmetry or asymmetry) may affect the instability configuration of structure. A finite element software for the nonlinear aerostatic stability analysis of cable-supported bridges (NASAB) is presented and discussed. The aerostatic failure mechanism of suspension bridges is also explained by tracing aerostatic instability path.