Ultrasonic Transducer Design for the Axial Flaw Detection of Dissimilar Metal Weld (이종금속 용접부 축방향 결함 검출을 위한 초음파 탐촉자 설계)

  • Yoon, Byung-Sik;Kim, Yong-Sik;Yang, Seung-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.536-542
    • /
    • 2011
  • Dissimilar metal welds in nuclear power plant are known as very susceptible to PWSCC flaws, and periodically inspected by the qualified inspector and qualified procedure during in-service inspection period. According to field survey data, the majority of their DMWs are located on tapered nozzle or adjacent to a tapered component. These types of configurations restrict examination access and also limit examination volume coverage. Additionally, circumferential scan for axially oriented flaw is very difficult to detect located on tapered surface because the transducer can't receive flaw response from reflector for miss-orientation. To overcome this miss-orientation, it is necessary adapt skewed ultrasonic transducer accomodate tapered surface. The skewed refracted longitudinal ultrasonic transducer designed by modeling and manufactured from the modelling result for axial flaw detection. Experimental results showed that the skewed refracted longitudinal ultrasonic transducer get higher flaw response than non-skewed refracted longitudinal ultrasonic transducer.

The Gasoline Atomization Characteristics and Static Pressure Distribution of Tapered Nozzle Swirl Spray (경사노즐 선회분사기의 가솔린 미립화 및 분무 내부 압력 분포)

  • Moon, Seok-Su;Choi, Jae-Joon;Bae, Choong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.3 s.258
    • /
    • pp.283-291
    • /
    • 2007
  • The static pressure distribution, atomization characteristics and velocity distribution of tapered nozzle swirl spray is analyzed and then compared with original swirl spray. The static pressure distribution inside the swirl spray is measured using a piezoresistive pressure transducer. Phase Doppler anemometry (PDA) is applied to measure and analyze the droplet size and velocity distribution of tapered nozzle and original swirl spray. The static pressure inside the spray shows the lower value compared to the atmospheric pressure and this pressure drop is getting attenuated as the taper angle is increased. The droplet size of tapered nozzle spray shows similar value compared to the original swirl spray at the horizontal mainstream while it shows increased value at vertical mainstream. The deteriorated atomization characteristics of tapered nozzle spray is improved by applying high fuel temperature injection without causing the spray collapse. The velocity results show that the larger portion of fuel is positioned with higher injection velocity, and the smaller portion of fuel is positioned with lower injection velocity with causing spatially non-uniform mixture distribution.

Characteristics Variation Analysis by Shape of Piezoelectric Ultrasonic Transducer with Non-Uniform Thickness (두께 불균일 압전 초음파 트랜스듀서의 형태에 따른 특성변화 해석)

  • Kim, Dong-Hyun;Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.271-278
    • /
    • 2008
  • The electro-mechanical characteristics were theoretically analyzed for the wideband ultrasonic transducer made of non-uniform thickness piezoelectric vibrator. This paper proposes a combination of exponential functions which describes the thickness variation along the length of the vibrator to derive the input admittance and power transfer function of the transducer. The bandwidth and the power transfer function of the transducer were investigated while the lateral shape of the vibrator changes. The results showed there is an optimum shape for the wideband characteristics of the transducer, and the bandwidth has increased up to over 100% as the ratio of minimum value of thickness to maximum value decreases. However, the power transfer function had a downward trend as the ratio of thickness decreases. Also we confirmed that even though the value of transfer function increases as the length of the piezoelectric vibrator increases, the shape providing wideband characteristics is very limited. It means that precision processing is required to manufacturing a wideband ultrasonic transducer with high efficiency.

Design of Mode Transducer between $TE_{10}$ Mode in Rectangular Waveguide and $TE_{11}$ Mode in Circular Waveguide (구형 도파관 $TE_{10}$모드와 원형 도파관 $TE_{11}$모드간의 모드변환기 설계)

  • Doo-Yeong Yang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.3
    • /
    • pp.246-253
    • /
    • 1996
  • In this paper, a problem that occurred in the telegraphist equation established by mode conversion method is solved as analysis tapered transmission line is applied to a waveguide taper. After comparing and analyzing the taper function with variant properties, we select on of taper functions not only that is easily designed but also that have good properties. And then we propose the applicant method to design the waveguide taper and deal with the design of mode transducer between rectangular waveguide and circular waveguide. The measured results of scattering coefficients for the mode transducer fabricated with designed data are agreed well with the theoretical results and the validity of the proposed design and analysis method has been confirmed.

  • PDF

A Study on the Fabrication and the Impedance Matching of SPUDT Type SAW Filter (단상 단방향 형태의 표면탄성파 필터 제작 및 임피던스 정합)

  • You Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.602-608
    • /
    • 2005
  • We have studied to obtain the SAW filter for the Single Phase Unidirectional Transduce. (SPUDT), was formed on the Langasite substrate and was evaporated by Aluminum-Copper alloy and then we performed computer-simulated by simulator. We can fabricate that the block weighted type IDT as an input transducer of the filter and the withdrawal weighted type IDT as an output transducer of the filter from the results of our computer-simulations. Also, we have performed to obtain the properly conditions about impedance matching of the SAW filter for SPUDT. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflector are 5000A and $3.6{\mu}m$, respectively. And the width of IDT' fingers is $2.4{\mu}m$, and the space between IDT' finger and reflector is $2.0{\mu}m$. Frequency response of the fabricated SAW filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 7.7MHz after when we have matched impedance. Also, we could obtain that ripple characteristics is less than 0.4dB and standing wave ratio is probably 1.5 after when we have matched impedance.

Design of An Orthomode Transducer for Use in Multi-Band Antenna Feeds (다중 대역 안테나 피드용 직교모드 변환기 설계)

  • 황순미;김영민;이석곤;안병철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.53-59
    • /
    • 2002
  • In this paper, we present design results for an orthomode transducer(OMT) to be used in multi-band antenna feeds. The OMT is realized in the form of a tapered square waveguide, where 18-20 GHz ports are placed in the taper region normal to the waveguide axis, while 30-45 GHz ports are placed in line with the waveguide axis. The reflection coefficient of each port is designed to be less than 20 dB, while the isolation between ports are greater than 15 dB. Thin septa are placed in side ports to reduce the effect of side ports on the return loss of the in-line port. The commercial software HFSS? is used to design the whole structure.

Improving Wave Propagation Performance of an Ultrasonic Waveguide for Heat Isolation (열 차단용 초음파 도파관의 전파성능 향상 연구)

  • 최인석;전한용;김인수;김진오
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.545-553
    • /
    • 2003
  • This paper is concerned with protecting piezoelectric transducers used in an ultrasonic flowmeter from the high temperature of hot fluid in a pipe by using a waveguide and with improving the propagation of ultrasonic longitudinal vibration in the waveguide. Waveguide material has been chosen for efficient insulation of heat transferred in the waveguide, and the minimum length of the waveguide for protecting piezoelectric transducer has been estimated. Forced response of the longitudinal vibration in a uniform circular rod has been obtained and the length of the waveguide has been selected for maximum amplitude. Longitudinal vibration response of a conically-tapered rod excited at a natural frequency has been obtained to confirm that wave motion is amplified as the cross-sectional size of the waveguide decreases along the axial direction. The fact that dispersion of a pulse wave in a waveguide is reduced as the cross-sectional radius is decreased has been examined theoretically and confirmed experimentally by using a single-rod waveguide. A bundle-type waveguide has proven to be a practical one through the evaluation of the wave propagation performance.