• Title/Summary/Keyword: Technology Computer Aided Design

Search Result 437, Processing Time 0.03 seconds

Developing Integrated Compressor Cooler System of 3D Printing Nozzle (3D 프린팅 노즐의 일체형 압출기 쿨링 시스템 개발)

  • Son, Ji-Hwan;Park, Hyun-Woo;Ha, Dong-Woo;Lee, Chang-U;Kim, Jin-Su;Kang, Seong-Ki
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.1
    • /
    • pp.6-12
    • /
    • 2017
  • In a large 3D printer when the cooler, which cools the filament, acts in one direction, the area directly exposed to the cooling is cooled to the proper temperature. However, the cooling effect on the opposite area is relatively less. It was found in experiments that filaments with a thickness of over 2 mm exhibit the cooling problem in one directional cooling. Consequently, cooling was performed to prevent the flow-down and to produce firm support leading to an improvement in product quality in extrusion. Further, the lay-up of a 3D printer with five guides combined with a duct was achieved. Analysis showed that the improvement in the cooling effect enables stable extrusion and lay-up and thus, reduces fabrication time.

Recent advances in the reconstruction of cranio-maxillofacial defects using computer-aided design/computer-aided manufacturing

  • Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.2.1-2.7
    • /
    • 2018
  • With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.

RPD framework fabrication using computer-aided design (CAD) and rapid prototyping (Computer-aided design (CAD) 및 쾌속조형술을 이용한 가철성 국소의치 수복 증례)

  • Park, Seon-Ah;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.94-99
    • /
    • 2017
  • Nowadays, digital dentistry is generally applied to prosthodontics with fabrication of inlays or any other fixed prostheses by utilizing CAD/CAM (computer-aided design/computer-aided manufacturing) technology and intraoral scanner. However, in fabricating removable prosthesis, there are some limitations for digital technology to substitute conventional casting method. Therefore, approaching removable prostheses fabrication with CAD/CAM technology would be a meaningful trial. In this case report, Kennedy class III mandibular edentulous patient who was in need of increasing the vertical dimension of occlusion was treated with removable partial denture using CAD and rapid prototyping technique. Surveying and designing the metal framework of the partial denture was performed with CAD, and sacrificial plastic pattern was fabricated with rapid prototyping technique. During the follow up period of nine months, the removable partial denture has provided satisfactory results in esthetics and function.

The Application of CAD/CAM in Dentistry (임상가를 위한 특집 1 - CAD/CAM 치과적 응용)

  • Choi, Ho-Sik;Moon, Ji-Eun;Kim, Sung-Hun
    • The Journal of the Korean dental association
    • /
    • v.50 no.3
    • /
    • pp.110-117
    • /
    • 2012
  • Dental computer-aided design (CAD) and computer-aided manufacturing (CAM) technology have rapidly progressed over the past 30 years. The technology, which can be used in the dental laboratory, the dental office and the form of production centers, has become more common in recent years. This technology is now applied to inlays, onlays, crowns, fixed partial dentures, removable partial denture frameworks, complete dentures, templates for implant installation, implant abutments, and even maxillofacial prostheses. Dentists and dental technicians, who want to use these techniques, should have certain basic knowledge about that. This article gives an overview of CAD/CAM technologies, histories and how it applies in prosthetic dentistry.

Electrical analysis of Metal-Ferroelectric - Semiconductor Field - Effect Transistor with SPICE combined with Technology Computer-Aided Design (Technology Computer-Aided Design과 결합된 SPICE를 통한 금속-강유전체-반도체 전계효과 트랜지스터의 전기적 특성 해석)

  • Kim, Yong-Tae;Shim, Sun-Il
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.1 s.34
    • /
    • pp.59-63
    • /
    • 2005
  • A simulation method combined with the simulation program with integrated circuit emphasis (SPICE) and the technology computer-aided design (TCAD) has been proposed to estimate the electrical characteristics of the metal-ferroelectric-semiconductor field effect transistor (MFS/MFISFET). The complex behavior of the ferroelectric property was analyzed and surface potential of the channel region in the MFS gate structure was calculated with the numerical TCAD method. Since the calculated surface potential is equivalent with the surface potential obtained with the SPICE model of the conventional MOSFET, we can obtain the current-voltage characteristics of MFS/MFISFET corresponding to the applied gate bias. Therefore, the proposed method will be very useful for the design of the integrated circuits with MFS/MFISFET memory cell devices.

  • PDF

IMPLEMENTATION OF PRODUCT DATA MANAGEMENT SYSTEM FOR DESIGN OF BRIDGE STRUCTURES

  • Jin-Suk Kang;Seung-Ho Jung;Yoon-Bum Lee;Kwang-Myong Lee
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1318-1323
    • /
    • 2009
  • In recent years, dramatic advances in information technology have motivated the construction industry to improve its productivity. Computer-based information technology includes Computer-Aided Design (CAD), Computer-Aided Engineering (CAE), Computer-Aided Manufacturing (CAM), Enterprise Resource Planning (ERP), Digital Mock-Up (DMU) and Product Data Management (PDM). Most construction industries are trying to apply these technologies for quality improvement, reduction of construction time and cost. PDM is very useful for managing data and process related to product design and manufacturing. PDM system has various functions such as drawing and engineering document management, product structure and structure modification management, part classification management, workflow management, and project management. In this paper, PDM system was applied to the design of steel-concrete composite girder bridge. To make a practical guidance for PDM implementation to bridge design, the procedure for its implementation was presented. Consequently, this paper could be useful to enhance the efficiency of bridge design.

  • PDF

ENHANCED FUZZY SLIDING MODE CONTROLLER FOR LAUNCH CONTROL OF AMT VEHICLE USING A BRUSHLESS DC MOTOR DRIVE

  • Zhao, Y.S.;Chen, L.P.;Zhang, Y.Q.;Yang, J.
    • International Journal of Automotive Technology
    • /
    • v.8 no.3
    • /
    • pp.383-394
    • /
    • 2007
  • Due to the clutch's non-linear dynamics, time-delays, external disturbance and parameter uncertainty, the automated clutch is difficult to control precisely during the launch process or automatic mechanical transmission (AMT) vehicles. In this paper, an enhanced fuzzy sliding mode controller (EFSMC) is proposed to control the automated clutch. The sliding and global stability conditions are formulated and analyzed in terms of the Lyapunov full quadratic form. The chattering phenomenon is handled by using a saturation function to replace the pure sign function and fuzzy logic adaptation system in the control law. To meet the real-time requirement of the automated clutch, the region-wise linear technology s adopted to reduce the fuzzy rules of the EFSMC. The simulation results have shown hat the proposed controller can achieve a higher performance with minimum reaching time and smooth control actions. In addition, our data also show that the controller is effective and robust to the parametric variation and external disturbance.

Fabrication of a custom polyetherketoneketone post-and-core with digital technology

  • Ju-Hyoung Lee;Gyu-Heon Lee
    • Journal of Technologic Dentistry
    • /
    • v.46 no.1
    • /
    • pp.15-19
    • /
    • 2024
  • An ideal post material should have physical properties similar to those of dentin. Post materials with high elastic moduli may cause root fractures. This clinical report describes the treatment of a severely damaged tooth using a recently introduced material. Polyetherketoneketone (PEKK) is a semicrystalline high-performance thermoplastic polymer. PEKK is a promising material for custom post-and-core fabrication because of its elasticity close to that of dentin, good shock absorbance, machinability, and low cost. A laboratory scanner was used to digitize the conventional impression of a severely damaged maxillary right first molar. A custom PEKK post-and-core was designed and milled using computer-aided design and computer-aided manufacturing technology. Using the proposed technique, a custom PEKK post-and-core was fabricated accurately and human error was reduced. Restoration was luted with resin cement. Custom PEKK post-and-core restorations are a viable alternative for treating severely damaged teeth.

Fabrication of computer-aided design/computer-aided manufacturing complete denture and conventional complete denture: case report (CAD/CAM system과 전통적인 방법을 이용한 총의치 동시 제작 증례)

  • Kim, Mi-Jin;Kim, Kang-Ho;Yeo, Dong-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.2
    • /
    • pp.141-148
    • /
    • 2016
  • Recently computer-aided technology has been widely used in dentistry. DENTCA$^{TM}$ CAD/CAM denture system (DENTCA Inc.), one of CAD/CAM systems for fabricating complete denture, tries to collect and store all of a patient's information at the first visit. This system aims to deliver denture at the second visit through utilizing the CAD/CAM software to access the stored data for designing the 3D denture model. The 3 dimensional (3D) denture will then be fabricated with 3D printer. Many case reports have evaluated clinical application of CAD/CAM system for fabricating complete dentures. This case report is about fabricating of complete dentures using DENTCA system and conventional method in same patient. With two cases, usefulness and limitation of DENTCA system could be evaluated.

Implant-assisted full denture using digital guide: a case report (무치악 환자에서 디지털 가이드를 이용한 임플란트 수복증례)

  • Kim, Wook Tae
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.202-209
    • /
    • 2021
  • By classifying temporary denture production for surgical guides, digital guide-based surgery, and final prosthesis production, the problems of each process were assessed in advance and the factors that could be improved were confirmed in this study. The manufacturing process of fusion dental prosthesis uses virtual programs and computed tomography images to manufacture devices using the latest technologies of computer-aided design/computer-aided manufacturing and three-dimensional printing, which enables implants to be placed in the desired location in advance. Moreover, implant placement is not dependent on the skill and condition of the dentist, and because it uses a computer system, it can always be performed at a constant and optimal position. This can reduce the remanufacturing rate compared with the general method, shorten the treatment period, and eliminate patient discomfort. Unlike the traditional method of using impression materials and plaster models, digital fusion dental prostheses would be evaluated as a technology for producing prosthesis through professional design technology and communication.