• Title/Summary/Keyword: Telemetry RF Sensor

Search Result 20, Processing Time 0.035 seconds

Capacitive Parameter Estimation of Passive Telemetry RF Sensor System Using RLS Algorithm (RLS 알고리즘을 이용한 원격 RF 센서 시스템의 정전용량 파라메타 추정)

  • Kim, Kyung-Yup;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.858-865
    • /
    • 2008
  • In this paper, Capacitive Telemetry RF Sensor System using Recursive Least Square (RLS) algorithm was proposed. General Telemetry RF Sensor System means that it should be "wireless", "implantable" and "batterless". Conventional Telemetry RF Sensor System adopts Integrated Circuit type, but there are many defects like complexity of structure and the limitation of large power consumption in some cases. In order to overcome these disadvantages, Telemetry RF Sensor System based on inductive coupling principle was proposed in this paper. Proposed Telemetry RF Sensor System is very simple because it consists of R, L and C and measures the changes of environment like pressure and humidity in the type of capacitive value. This system adopted RLS algorithm for estimation of this capacitive parameter. For the purpose of applying RLS algorithm, proposed system was mathematically modelled with phasor method and was quasi-linearized. As two parameters such as phase and amplitude of output voltage for estimation were needed, Phase Difference Detector and Amplitude Detector were proposed respectively which were implemented using TMS320C2812 made by Texas Instrument. Finally, It is verified that the capacitance of proposed telemetry RF Sensor System using RLS algorithm can be estimated efficiently under noisy environment.

Implementation of Passive Telemetry RF Sensor System Using Unscented Kalman Filter Algorithm (Unscented Kalman Filter를 이용한 원격 RF 센서 시스템 구현)

  • Kim, Kyung-Yup;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1861-1868
    • /
    • 2008
  • In this paper, Passive Telemerty RF Sensor System using Unscented Kalman Filter algorithm(UKF) is proposed. General Passive Telemerty RF Sensor System means that it should be "wireless", "implantable" and "batterless". Conventional Passive Telemerty RF Sensor System adopts Integrated Circuit type, but there are defects like complexity of structure and limit of large power consumption in some cases. In order to overcome these kinds of faults, Passive Telemetry RF Sensor System based on inductive coupling principle is proposed in this paper. Because passive components R, L, C have stray parameters in the range of high frequency such as about 200[KHz] used in this paper, Passive Telemetry RF Sensor System considering stray parameters has to be derived for accurate model identification. Proposed Passive Telemetry RF Sensor System is simple because it consists of R, L and C and measures the change of environment like pressure and humidity in the type of capacitive value. This system adopted UKF algorithm for estimation of this capacitive parameter included in nonlinear system like Passive Telemetry RF Sensor System. For the purpose of obtaining learning data pairs for UKF Algorithm, Phase Difference Detector and Amplitude Detector are proposed respectively which make it possible to get amplitude and phase between input and output voltage. Finally, it is verified that capacitive parameter of proposed Passive Telemetry RF Sensor System using UKF algorithm can be estimated in noisy environment efficiently.

Time-Varying Parameter Estimation of Passive Telemetry RF Sensor System Using RLS Algorithm (RLS 알고리즘을 이용한 원격 RF 센서 시스템의 시변 파라메타 추정)

  • Kim, Kyung-Yup;Yu, Dong-Gook;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.29-33
    • /
    • 2007
  • In this paper, time-varying parameter of passive telemetry RF sensor system is estimated using RLS(Rescursive $\leq$* Square) algorithm. In order to overcome the problems such as power limits and complication that general RF sensor system including IC chip has, the principle of inductive coupling is applied to model sensor system The model parameter is rearranged for applying RLS algorithm based on mathematical model to the derived model using inductive coupling principle. Time variant parameter of rearranged model is estimated using forgetting factor, and in case measured data is contaminated by noise and modelling error, the performance of RLS algorithm characterized by the convergence of squared error sum is verified by simulation.

  • PDF

Passive Telemetry Capacitive Humidity Sensor System using RLSE Algorithm (RLSE알고리즘을 이용한 원격 정전용량형 습도 센서 시스템)

  • Kyung-Yup Kim;Joon-Tark Lee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.569-576
    • /
    • 2004
  • In this paper, passive telemetry capacitive humidity sensor system using a RLSE(Recursive Least Square Estimation) technique is proposed. To overcome the problem like power limits and complications that general passive telemetry sensor system including IC chip has, the principle of inductive coupling is applied to model the sensor system. Specially. by applying the forgetting factor we show that the accuracy of its estimation can be improved even in the case of time varying parameter and also the convergence time can be reduced.

Passive Telemetry Sensor System using RLSE Based Real Time Estimation Technique with Optimal Forgetting Factor

  • Lee, Joon-Tark;Kim, Kyung-Yup
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.515-520
    • /
    • 2004
  • In this paper, a passive telemetry RF capacitive humidity sensor system using a RLSE(Recursive Least Square Estimation) technique is proposed. To overcome these trouble problems such as a power limitation and a estimation complexity that the general passive telemetry sensor system including It chip has, the principle of inductive coupling was applied to the modeling of a passive telemetry RF capacitive humidity sensor system and its capacitance was estimatedd by the RLSE algorithm. Specially, by introducing the optimal forgetting factor, we showed that the accuracy of its estimation was improved even in the time varying system and also the convergence time was reduced.

  • PDF

Implementation of Capacitive Passive Telemetry RF Sensor System Using RLS Estimation Algorithm (RLS 추정 알고리즘을 이용한 정전용량형 원격 RF 센서 시스템 구현)

  • Kim, Gyeong-Yeop;Yu, Dong-Guk;Lee, Jun-Tak
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.11a
    • /
    • pp.131-137
    • /
    • 2007
  • 본 연구에서는 RLS(Rescursive Least Square) 추정 알고리즘을 이용하여 정전용량형 센서를 사용한 원격 RF 센서 시스템을 구현하고자 한다. IC 칩 형태의 원격 RF 센서 시스템이 가지는 구성의 복잡성 그리고 전력소모 문제를 해결하기 위해 보다 간단한 유도결합모델이 제안된다. 원격 RF 시스템은 페이저법을 이용하여 수학적으로 모델링되며, 모델기반의 RLS 알고리즘을 적용하기위해 시스템의 파라메타를 재배열한다. 오차 제곱합의 수렴특성을 가진 RLS 알고리즘을 이용하여 정전용량 파라메타를 추정한다. 실제 위상차를 측정하기 위해 Exclusive OR를 이용한 위상차 감지 장치를 제안한다. 센서로는 각종 환경 측정-습도, 압력 등-에 실제 활용되고 있는 정전용량형 센서를 채택한다. 잡음을 내포한 측정 데이터에 대한 추정 성능을 확인함으로써 그 유효성을 검증하고자 한다.

  • PDF

Time Variant Parameter Estimation using RLS Algorithm with Adaptive Forgetting Factor Based on Newton-Raphson Method (Newton-Raphson법 기반의 적응 망각율을 갖는 RLS 알고리즘에 의한 원격센서시스템의 시변파라메타 추정)

  • Kim, Kyung-Yup;Lee, Joon-Tark
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.04a
    • /
    • pp.435-439
    • /
    • 2007
  • This paper deals with RLS algorithm using Newton-Raphson method based adaptive forgetting factor for a passive telemetry RF sensor system in order to estimate the time variant parameter to be included in RF sensor model. For this estimation with RLS algorithm, phasor typed RF sensor system modelled with inductive coupling principle is used. Instead of applying constant forgetting factor to estimate time variant parameter, the adaptive forgetting factor based on Newton-Raphson method is applied to RLS algorithm without constant forgetting factor to be determined intuitively. Finally, we provide numerical examples to evaluate the feasibility and generality of the proposed method in this paper.

  • PDF

Passive Telemetry Capacitive Humidity Sensor System using RLSE Algorithm

  • Lee, Joon-Tark;Park, Young-sik;Kim, Kyung-Yup
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.04a
    • /
    • pp.495-498
    • /
    • 2004
  • In this paper, passive telemetry capacitive humidity sensor system using a RLSE(Recursive Least Square Estimation) technique Is proposed. To overcome the problem like power limits and complications that general passive telemetry sensor system including IC chip has, the principle of inductive coupling is applied to model the sensor system. Specially, by applying the forgetting factor, we show that the accuracy of its estimation can be improved even in the case of time varying parameter and also the convergence time can be reduced.

  • PDF

Development of a wireless telemetry system based on MICS standard (MICS 표준에 기반한 무선 텔레메트리 시스템 개발)

  • Lee, Seung-Ha;Park, Il-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.