• Title/Summary/Keyword: Temperature

Search Result 88,208, Processing Time 0.081 seconds

Prediction of the Apparent Temperature of an Object under the Infrared Waveband (적외선 파장대에서의 물체의 겉보기온도 예측)

  • Jung, Jinsoo;Kauh, S. Ken;Yoo, Hoseon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.352-363
    • /
    • 1999
  • Target detection by the infrared imager depends on the apparent temperature difference between the target and the background, so it is essential to predict apparent temperature variations for this purpose. In this study, thermal analysis program Including conduction, convection and radiation is developed and applied to a representative geometry adequate for examining the apparent temperature characteristics. The results show that the longwave emissivity in association with the background temperature affects the apparent temperature strongly but does not affect the physical temperature. It is revealed that the background temperature plays a role of tuning the apparent temperature. As the longwave emissivity decreases, the apparent temperature decreases when the target is hotter than the background, whereas it increases in the reversed situation. These findings imply that an effective surface treatment, such as painting of a less emissive material, may provide a less detection probability and contribute to preventing the target from being detected at night.

Surface Temperature Measurement in Microscale with Temperature Sensitive Fluorescence (온도 민감 형광을 이용한 마이크로 스케일 표면온도 측정)

  • Jung Woonseop;Kim Sungwook;Kim Ho-Young;Yoo Jung Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.153-160
    • /
    • 2006
  • A technique for measuring surface temperature field in micro scale is newly proposed, which uses temperature-sensitive fluorescent (TSF) dye coated on the surface and is easily implemented with a fluorescence microscope and a CCD camera. The TSF dye is chosen among mixtures of various chemical compositions including rhodamine B as the fluorescent dye to be most sensitive to temperature change. In order to examine the effectiveness of this temperature measurement technique, numerical analysis and experiment on transient conduction heat transfer for two different substrate materials, i. e., silicon and glass, are performed. In the experiment, to accurately measure the temperature with high resolution temperature calibration curves were obtained with very fine spatial units. The experimental results agree qualitatively well with the numerical data in the silicon and glass substrate cases so that the present temperature measurement method proves to be quite reliable. In addition, it is noteworthy that the glass substrate is more appropriate to be used as thermally-insulating locally-heating heater in micro thermal devices. This fact is identified in the temperature measuring experiment on the locally-heating heaters made on the wafer of silicon and glass substrates. Accordingly, this technique is capable of accurate and non-intrusive high-resolution measurement of temperature field in microscale.

Reliability Assessment of Temperature Indicator for Simplified Measurement on Conservation Environment of Cultural Heritage (문화재 보존환경 간이 측정을 위한 온도지시카드 신뢰성 평가)

  • Lim, Bo-A;Shin, Eun-Jeong;Lee, Sun-Myung
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.59-68
    • /
    • 2010
  • Cultural heritages are damaged by surrounding several environmental factors. Main factors are temperature, humidity, light, atmosphere and indoor pollutant, organism, etc. Therefore, to prevent damage of cultural heritage from such environmental factor, conservation environment monitoring becomes more important. Indicator is one of the simple method for environment monitoring. It can be used without expensive and complex equipments. However, it should be performed scientific examination for application to cultural heritage. In this study, some Temperature Indicators were chosen and reliability assessment was carried out for application to cultural heritage. Brightness($L^*$) is selected for reliability assessment factor. As a result of lab test, Temperature Indicators were not influenced greatly in humidity change. When they were exposed to setting temperature, the color was changed in setting temperature area and ${\pm}2^{\circ}C$ part of setting temperature. Especially brightness value was high in setting temperature area. Also, Temperature Indicators were stabilized after about 16 minutes when were exposed to temperature difference of $10^{\circ}C$ and when temperature difference with exposure environment is smaller, stabilization time shortened. Therefore, it is a possible to confirm that selected Temperature Indicator is reliable product through measurement of color difference value and naked eye observation.

  • PDF

Measurement of Junction Temperature in High Power LED Module with Property Analysis of Single Package (단일 패키지의 특성 분석을 통한 고출력 발광 다이오드 모듈의 접합 온도 측정)

  • Lee, Se-IL;Kim, Woo-Young;Jeong, Young-Gi;Yang, Jong-Kyung;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.12
    • /
    • pp.973-977
    • /
    • 2010
  • The temperature of junction in LED affects the life time and performance. however, the measurement of junction temperature in module is very difficult. In this paper, to measure the junction temperature in LED module, optical and electrical properties is measured in single package in temperature from 25 [$^{\circ}C$] to 85 [$^{\circ}C$], and then junction temperature can is estimated in module with measuring the average voltage of single package. As results, the junction temperature of single package is measured the temperature of 61.2 [$^{\circ}C$] in ambient temperature, also, the junction temperature of LED module is measured the temperature of 72.5 [$^{\circ}C$] in ambient temperature.

Skin Temperature Responses of Hanbok When It Worn (한복 착용에 따른 피보온의 변화)

  • 송명견;신정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.6
    • /
    • pp.763-770
    • /
    • 2002
  • The objective of the study was to investigate skin temperature responses of Hanbok when it was worn. Two healthy females(average 21 years, 155cm and 60kg were exposed to a climatic chamber(Room Temp. $21{\pm}1^{\circ}C,\;52{\pm}2%R.H.$, 0.15m/s). During the experiment, rectal temperature, skin temperature of 9 areas, clothing microclimate, subjective sensation were measured. Chima and Jogory to be made of silk nobang(SN) or Ramie were worn for summer. Polyester(P) Chima and Jogori(R) could be wort for spring and autumn. For winter, silk Chima, Jogori(S) and Durumagi(D) were commonly worn. Rectal temperature was high in order of naked(N), R, SN, P, S, D. However Mean skin temperature was reversely high in order of D, S, SN, R, P, naked. In naked, skin temperature was high in order of head, trunk upper extremity and lower extremity. But on wearing of Hanbok, it was the highest at the chest except head regardless of kinds of clothing ensembles. Skin temperature of upper arm was secondly highest on wearing the silk ensemble and the Durumagi ensemble, but skin temperature of buttock was secondly highest on wearing the silk nobang ensemble and the ramie ensemble. Skin temperature on wearing the silk ensemble was generally higher than those on other clothing ensembles. Local and mean skin temperatures on wearing the silk ensemble and the Durumagj ensemble were generally higher than on other clothing ensembles. Heat resistance of the fabric might have affected on the local skin temperature.

Study on the Vinyl House Heating by Warm Air (농업용 비닐하우스의 온풍난방에 관한 기초적 연구)

  • 조진구;이근후
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.3
    • /
    • pp.4483-4491
    • /
    • 1977
  • The results obtained are as follows; 1. The variation of the temperature in a vinyl house without heating system is similar to that of air temperature in a day. The difference of maximum temperature and minimum one in a day is 27$^{\circ}C$ which is two times greater than the daily difference of air temperature. 2. When the length of the duct is increased, the high temperature zone is built up in the direction of warm air discharge from the duct, and the low temperature zone is built up in the opposite direction of warm air discharge. But, in case of the duct length is short (0.05 L), the temperature distrubution in a vinyl house become uniform. It is concluded that the shorter length of the duct, the better the distribution of the temperature in a vinyl house is. 3. When the duct is installed at high position, the high temperature zone is built up in the upper zone of the vinyl house and the low temperature zone is built up in the lower zone. And when the position of the duct is low, the rate of temperature variation along the vertical direction become high, and the direct contact of warm air with the plant in the house is occured. It is concluded that the duct should be installed at the position of slightly higher than the plant height. 4. When the fuel consumption rate is fixed at the 101/hr, the lowest temperature warming rate in the vinyl house is 5$^{\circ}C$ without regard to the air temperature.

  • PDF

A Comparison Study on the Skin Temperature on the Adult Male. Female at Environmental Temperature (각 환경기온하에서의 성인 남 . 여자의 피부온 비교)

  • 심부자
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.227-246
    • /
    • 1997
  • With a view of to providing basic data for designing male's and female's clothes, heslthy males and females(five each) were exposed to three different environmental temperature( $20{\pm}1.0^{\circ}C$ $28{\pm}1.0^{\circ}C$,$32{\pm}1.0^{\circ}C$ in the nude. Their adaptation of skin temperature, physilogical responses, oral temperature, blood pressure, pulse rates) and psychological reactions (thermal, comfort and perceptive sweat sensations) were analyzed to be as follows; The subjects's skin temperature had a similar look of adaptation, but the stability of skin temperature differed at the $20{\pm}1.0^{\circ}C$and at the $28{\pm}1.0^{\circ}C$ Males had higher skin temperatures at three environmental temperatures, but females showed a higher temperature change at the $20{\pm}1.0^{\circ}C$ and$28{\pm}1.0^{\circ}C$ and males at the $32{\pm}1.0^{\circ}C$ Thus females were more resistant to the cold, while male were more resistant to the heat. As environmental temperature increased, oral temperature and pulse rates also grew up. Females turned higher in oral temperature and lower in blood pressure, but both sexes had a normal range of physiological reactions. Even though three environmental temperature were same changes in thermal sensation at and in perceptive sweat sensation at $28{\pm}1.0^{\circ}C$and in perceptive sweat sensation at$32{\pm}1.0^{\circ}C$ the two sexes had the same response in comfort sensation at the three environmental temperature.

  • PDF

The effect of temperature in high temperature SHPB test (고온 SHPB실험에서 온도의 영향)

  • Park, Kyoung-Joon;Yang, Hyun-Mo;Min, Oak-Key
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.349-354
    • /
    • 2001
  • The split Hopkinson pressure bar has been used for a high strain rate impact test. Also it has been developed and modified for compression, shear, tension, elevated temperature and subzero tests. In this paper, SHPB compression tests have been performed with pure titanium at elevated temperatures. The range of temperature is from room temperature to $1000^{\circ}C$ with interval of $200^{\circ}C$. To raise temperature of the specimen, a radiant heater which is composed of a pair of ellipsoidal cavities and halogen lamps is developed at high temperature SHPB test. There are some difficulties in a high temperature test such as temperature gradient, lubrication and prevention of oxidation of specimen. The temperature gradient of specimen is affected by the variation of temperature. Barreling occurred at not properly lubricated specimen. Stress-strain relations of pure titanium have been obtained in the range of strain rate at $1900/sec{\sim}2000/sec$ and temperature at $25^{\circ}C{\sim}1000^{\circ}C$.

  • PDF

Analyzing Impact of the Effect of Greenbelts on the Land Surface Temperature in Seoul Metropolitan Area (수도권 그린벨트가 지표면 온도에 미치는 영향 분석)

  • Kim, Hee-Jae
    • Journal of Urban Science
    • /
    • v.9 no.1
    • /
    • pp.17-31
    • /
    • 2020
  • This study aims to analyze the relations among greenbelt, urban land surface temperature empirically in order to assess the environmental effects of the greenbelt in the Seoul metropolitan area, objectively. For this purpose, this study conducts an empirical analysis of impacts of greenbelt on urban land surface temperature using a multiple-regression model. The main data employed in the analysis include real-time air pollution data, Landsat 8-OLI Landsat imagery data, KLIS data and Jip-gye-gu data. The major findings are summarized as follows. NDVI has a negative (-) correlation with the land surface temperature, and the urban temperature is high in areas with poor vegetation. The land surface temperature is low in residential or commercial areas, while the temperature is high in industrial areas. The temperature is low in green fields, open spaces, and river areas. it is found that the urban land surface temperature is low in the greenbelt zone. In the greenbelt zone, there is an effect that reduces the land surface temperature by 1% on average, as compared to that at the center of the Seoul metropolitan area. Especially, the center of the Seoul metropolitan area, in a range from 0.6% to 1.9% of the average temperature, the temperature gets lower up to approximately 3km from the greenbelt boundary.