• Title/Summary/Keyword: Temperature environmental tester

Search Result 30, Processing Time 0.03 seconds

Numerical Analysis of Thermal Flow for Materials of Combined Weapon System in Large Environmental Tester (대형 환경시험조 내의 복합무기체계 재료에 대한 열유동 수치해석)

  • Kim, Sung-Dae;Ryoo, Seong-Ryoul;Baek, Sang-Hwa;Lee, Jeong-Yong;Park, So-Jin;Kim, Chul-Ju;Ko, Han-Seo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3144-3149
    • /
    • 2007
  • A numerical analysis for temperature distribution of four different materials such as iron, silicon, aluminum and PVC has been performed in this study to predict thermal behaviors of combined weapon systems in a large environmental tester. Thus, experimental conditions have been proposed using a calculating software (SolidWorks 2007 COSMOS FloWorks) to prepare for field tests and analyze heat flow inside the environmental tester and temperature distributions of materials. The boundary conditions of the analysis are composed of inlet and outlet conditions of the environmental tester with different pressures and the limit of low temperature of -30$^{\circ}C$. The soaking time of the system in the environmental tester has been calculated by this commercial program in this study to carry out the experiment.

  • PDF

Development of Numerical Analysis Technique of Thermal Flows for Experiment of Combined Weapon Systems (복합무기체계 실험을 위한 열유동 수치해석 기법 개발)

  • Kim, Sung-Dae;Tyoo, Seong-Tyoul;Baek, Sang-Hwa;Lee, Jeong-Yong;Park, So-Jin;Kim, Chul-Ju;Ko, Han-Seo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.397-400
    • /
    • 2008
  • A numerical analysis has been performed in this study to predict thermal behaviors of combined weapon systems in a large environmental tester. Also, temperature distributions of the materials of the system have been measured for the experimental conditions. The calculated thermal flow characteristics and the measured temperature distributions of the materials for the weapon systems have been analyzed to prepare for field tests in the environmental tester. The boundary conditions of the analysis are composed of inlet and outlet conditions of the environmental tester with various pressures and the limit of low temperature of -25$^{\circ}$C. The soaking time of the system in the environmental tester has been obtained by developed programs in this study to carry out the experiment in the predicted conditions.

  • PDF

Development of Fuzzy Controller for Temperature Environment Tester Using Thermoeletric Module (열전소자를 이용한 온도 환경시험기의 퍼지제어기 개발)

  • Hwang, Gi-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.5
    • /
    • pp.1228-1234
    • /
    • 2015
  • In this paper, a fuzzy controller using thermoelectric for temperature environmental tester is developed. The new structure of fuzzy controller based temperature environmental tester is proposed and implemented to maintain a stable temperature and improve temperature change speed. In order to evaluate the efficiency, an experiment is setup to compare PID controller with our proposed controller. The experimental results, we proved that our proposed fuzzy controller has better performance than PID controller.

A Study of Aging Effect for Train Carbody Using Accelerated Aging Tester

  • Nam, Jeong-Pyo;LI, Qingfen;LI, Hong
    • International Journal of Railway
    • /
    • v.1 no.3
    • /
    • pp.113-116
    • /
    • 2008
  • The long-tenn exposure of polymeric composite materials to extreme-use environments, such as pressure, temperature, moisture, and load cycles, results in changes in the original properties of the material. In this study, the effect of combined environmental factors such as ultraviolet ray, high temperature and high moisture on mechanical and thermal analysis properties of glass fabric and phenolic composites are evaluated through a 2.5 KW accelerated environmental aging tester. The environmental factors such as temperature, moisture and ultraviolet ray applied of specimens. A xenon-arc lamp is utilized for ultraviolet light and exposure time of up to 3000 hours are applied. Several types of specimens - tensile, bending, and shear specimens that are warp direction and fill direction are used to investigate the effects of environmental factors on mechanical properties of the composites. Mechanical degradations for tensile, bending and shear properties are evaluated through a Universal Testing Machine (UTM). Also, storage shear modulus, loss shear modulus and tan a are measured as a function of exposure time through a Dynamic Mechanical Analyzer (DMA). From the experimental results, changes in material properties of glass fabric and phenolic composites are shown to be slightly degraded due to combined environmental effects.

  • PDF

Design and Construction of a High Temperature Creep Tester for Thin Film Specimens (박막시험편용 고온 크리프 시험기의 설계 및 제작)

  • Ko, Gyoung-Dek;Lee, Sang-Shin;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.253-259
    • /
    • 2007
  • A new material tester has been developed to measure mechanical properties of thin film specimens at high temperature. It is useful for observing oxide film growth or local deformation on the surface, and for measuring creep strength. Main characteristics of the tester is as follows; First, high temperature is achieved by Joule heating generated by electricity passing through the specimen, which does not need to enclose the specimen by a furnace or a heating chamber. The exposed specimen enables one to observe the surface during the test. Because the overall size of the test rig is compact, the whole test rig can be placed in a chamber for environmental controlled tests. The loading device is from a level scales. Not only static load with fixed counter weight, but also variable load by moving counter weight controlled remotely can be applied for an ordinary creep test and creep-fatigue test, respectively. The detail of the construction, operation principle, and the specification are described. And also, an example of test result obtained using the creep tester is presented.

A Study for Adopting the Temperature Control Unit on Memory Device Tester Based on Principle of Thermoelectric Semiconductor (열전소자 원리를 이용한 부품 Tester용 온도공급 장치 연구 (메모리 Device Tester용 온도제어장치 도입을 위한 연구))

  • Kim, Sun-Ju;Hong, Chul-Ho;Shin, Dong-Uk;Seo, Seong-Bum;Lee, Moo-Jea
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.414-416
    • /
    • 2003
  • As environmental conditions for memory products are increasingly high speed/high density, adopting diverse system configuration, it's more and more difficult for current component tester to adopt the actual condition of field application. If system test screening is realized in component level, test coverage failure can be made more secured in the initial stage, evaluation cost can be reduced and the effectiveness of investment for the facility can be maximized. Based on the above background, component automatic system tester was developed and showed off satisfactory results per each memory device family. In this paper, component quality stabilization strategy and cost saving for tester investment through future Quality monitoring and application to mass production will be presented.

  • PDF

Aging Characteristics of Glass Fabric/Phenolic Composites for Tilting Train Using Accelerated Aging Tester (가속노화시험장치를 적용한 틸팅열차용 유리섬유직물/페놀릭 복합재의 노화특성 평가)

  • Yoon Sung-Ho;Nam Jung-Pyo;Hwang Young-Eun;Lee Sang-Jin;Shin Kwang-Bok
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.2
    • /
    • pp.188-194
    • /
    • 2005
  • Aging characteristics of glass fabric/phenolic composites for tilting train subjected to combined environmental aging factors were investigated. A 2.5KW accelerated aging tester with a xenon-arc lamp was used to provide environmental aging factors such as temperature, moisture, and ultraviolet. A series of aging tests were conducted up to 3000 hours and several types of specimens were prepared along the warp direction and the fill direction. Mechanical degradations for tensile, flexural, and shear properties were evaluated as a function of exposure times through a material testing system. Thermal analysis properties such as storage shear modulus, loss shear modulus, and tan 3 were measured through a dynamic mechanical analyzer. Finally exposed surfaces of the composites were examined using a scanning electron microscope. According to the experimental results, mechanical properties and thermal analysis properties of glass fabric/phenolic composites were found to be slightly degraded as a function of exposure times due to combined environmental effects.

Corrosion Fatigue Characteristics of A106-GrB Steel Weldments in NaCl solution (A106 GrB강 용접부의 염수중 부식피로 특성)

  • 김철환
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.143-149
    • /
    • 1997
  • the horizontal corrosion fatigue tester has been developed for investigating environmental strength. Using this tester, we investigated about corrosion fatigue caracteristic for A106 GrB steel weldments in 3.5% synthetic seawater and room temperature. Considered parameter is only frequency of 1,3 and 5Hz. and Corrosion fatigue crack length was measured by DC potential difference method. From the results, we could find that the horizontal corrosion fatiued tester could be well applied to estimation of fatigue strength. and In case of 5Hz, corrosion fatigue crack growth path of A106 GrB steel weldment was transgranular, and of 1 and 3Hz showed that transgranular and intergranular was mixed. Also, Corrosion fatigue crack growth caracteristic values estimated in each frequency were C=9.33 x 10-9 and m=2.93 in 1Hz, C=9.77x10-10 and m=3.47 in 3Hz, C=1.02x10-10 and m=4.05 in 1Hz

  • PDF

Environmental aging characteristics of carbon/epoxy composite for train carbody (철도차량 차체용 탄소섬유/에폭시 복합재의 환경노화 특성 평가)

  • Oh, Jin-Oh;Yoon, Sung-Ho;Kim, Jung-Suk;Han, Seong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.824-829
    • /
    • 2007
  • Mechanical and thermal analysis properties of carbon fiber/epoxy composite for train carbody were evaluated by varying with environmental factors such as ultraviolet, temperature, and moisture. Accelerated environmental aging tester was utilized for this study. Testing temperature was set to $80^{\circ}C$ and ultraviolet was obtained through xenon-arc lamp. To consider moisture, water sprayed on specimen for 18 minutes every 2 hour. All the specimens were made of CF1263/Epoxy composite. Mechanical properties such as tensile, bending, and shear properties were evaluated through a material testing system. Also, thermal analysis properties such as storage shear modulus, loss shear modulus, and tan ${\delta}$ were measured through dynamic mechanical analyzer. Finally surfaces of the composite exposed to environmental factors were examined using a scanning electron microscope. From experimental results, those properties of CF1263/Epoxy composite were shown to be slightly decreased due to environmental factors.

  • PDF

Physical Properties and Sulfidation Kinetics of Mn-Based Sorbent for Hydrogen Sulfide Removal (황화수소 제거를 위한 망간계 탈황제의 물리적 특성과 황화반응 속도)

  • Oh, Kwang-Joong;Shon, Byung-Hyun;Choi, Eun-Hwa;Yi, Gang Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.2067-2076
    • /
    • 2000
  • The experiments have been made to develop manganese-based sorbent(MT, MFT) for the removal of hydrogen sulfide from simulated hot coal gases. Manganese-based sorbents were tested in an ambient-pressure fixed-bed reactor to calculate H2S removal efficiency. and a three hole jet attrition tester to characterize the sorbent physical properties. According to the experimental results of attrition test. the attrition resistance of 5% bentonite containing sorbent was higher than that of 2% bentonite. The attrition resistances of both sorbents increased with induration temperature. Effects of sulfidation temperature. space velocity. and $H_2S$ concentrations on the $H_2S$ removal efficiency were investigated. Experimental results showed that $H_2S$ could be removed from 5,100ppmv to 20ppmv at $450^{\circ}C$, and to 30~65ppmv at $550{\sim}650^{\circ}C$ for both MT/MFT sorbents. As for the change of space velocity, the breakthrough time was decreased with space velocity.

  • PDF