• 제목/요약/키워드: Temporary stabilizing measures

검색결과 3건 처리시간 0.015초

강합성 2주형 사장교의 시공중 내풍 안정성 확보 방안 연구 (Temporary Stabilizing Measures during Construction of a Steel Composite 2-Edge Girder Cable Stayed Bridge)

  • 김영민;김대영
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.63-66
    • /
    • 2008
  • The bridge deck section composed of a concrete slab resting on two I-beam girders are known to be susceptible to flutter instability and vortex shedding. Moreover, the cable stayed bridge in construction is more vulnerable to wind rather than in service when the free cantilever construction method is applied. This paper describes the effect of the dynamic wind loads on the bridge during construction and the effect of alternative temporary stabilizing measures. Therefore, a series of wind tunnel tests and numerical analysis were carried out to determine if any countermeasures were required.

  • PDF

내풍케이블 배치에 따른 가설 중 사장교의 공기역학적 거동 비교 (Comparison of Aerodynamic Responses for Cable-Stayed Bridges during Construction with Temporary Stabilizing Measures)

  • 조재영;김영민;이학은
    • 한국강구조학회 논문집
    • /
    • 제19권2호
    • /
    • pp.147-160
    • /
    • 2007
  • 사장교 가설 시 태풍에도 내풍안정성을 확보할 수 있도록 내풍케이블 가설공법에 대한 심도 있는 실험을 수행하였다. 주경간이 각각 475m, 230m인 강합성 사장교에 대하여 가설단계별로 내풍케이블의 배치를 다양하게 적용하여 동적 풍하중이 가설 중 사장교에 미치는 영향을 전교모형실험을 통해 검토하였으며 이를 위해 풍속 별로 캔틸레버 단부의 정적 및 동적 변위, 주탑상부의 가속도 그리고 주탑 하단부의 교축방향 휨모멘트를 산정하였다. 연구 결과 캔틸레버 당 두 세트의 수직 내풍케이블이 가장 효과적인 제진대책임을 알 수 있었다. 캔틸레버 한 쪽 길이가 약 105m인 경우 한 세트의 수직 내풍케이블도 상당한 제진효과를 발휘하였으며 캔틸레버 길이가 200m 이상의 경우 수직케이블과 우물통 경사케이블이 조합된 경우와 캔틸레버 당 두 세트의 경사 내풍케이블도 좋은 제진방안으로 판단된다. 우물통 상단에 연결되는 경사케이블은 캔틸레버 단부 부근에 설치된 경우에만 어느 정도 제진효과가 나타났다.