• 제목/요약/키워드: Thermocouples

검색결과 264건 처리시간 0.034초

복사 간섭 보정을 통한 초고온 가스 온도 측정 방법 (Temperature Measurement Method with Radiation Correction for Very High Temperature Gas)

  • 김찬수;홍성덕;서동운;김용완;이원재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2059-2063
    • /
    • 2008
  • When a thermocouple is placed in a high temperature gas-flow stream, the measured temperature could be biased from the true gas temperature due to a large radiation heat loss from a thermocouple surface to its surroundings. In this study, two thermocouples of unequal diameters with 1/8 inch and 1/16 inch are used to correct the radiation effect. The method is called the reduced radiation error (RRE). The preliminary test results show that the radiation and the sheath conduction cannot be negligible for the gas temperature measurement. To minimize the sheath conduction effect, all the thermocouples will have a grounded junction and 1/8 inch thermocouple will be replaced with 1 mm thermocouples. In addition, the computational fluid dynamics code analysis shows that there is a negligible temperature difference between the positions where the thermocouples were installed.

  • PDF

Laser와 열전대를 이용한 연기선단의 위치 추적 비교에 관한 연구 (The tracking of a smoke front under a ceiling by a laser sheet and thermocouples)

  • 김명배;한용식;윤명오;김진곤
    • 한국화재소방학회논문지
    • /
    • 제12권3호
    • /
    • pp.11-20
    • /
    • 1998
  • 천장아래에 형성된 연기흐름을 대상으로 Laser 평면광과 열전대를 이용하여 연기선단의 위치를 추적하였다. 새로운 실험방법을 이용하여 연기선단의 도착순간을 열전대의 온도신호로부터 판단하는 종래의 직관적 기준을 평가하였다. 이러한 실험방법에서 사용된 Laser 평면광은 연기를 가시화 하기 위한 종래의 여러방법에 비교하여 뚜렷한 장점들이 있음을 입증하였다.

  • PDF

Experimental Study on Transient Heating of the Glass Panel in the Infrared Heating Chamber

  • Lee, Kong-Hoon;Kim, Ook-Joong;Ha, Su-Seok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.499-502
    • /
    • 2004
  • The temperature distribution of a glass plate heated in the infrared heating chamber has been investigated. Temperature of the glass panel is measured using a set of thermocouples and the optical pyrometer. Temperatures measured by thermocouples have good agreement with those by the pyrometer. The temperature uniformity of the panel is improved with wall reflectivity, which is one of the important factors to uniformly heat the panel

  • PDF

이원계 Co-C 공정계 온도 고정점의 특성 (Phase transition features of binary Co-C eutectic temperature fixed-point)

  • 김용규;양인석;감기술
    • 센서학회지
    • /
    • 제14권6호
    • /
    • pp.381-386
    • /
    • 2005
  • A Co-C eutectic cell for thermocouple calibration was manufactured and tested to investigate its phase transition characteristics using Type B thermocouples. It was observed that the freezing plateaus were flatter than those of melting, but the melting points were closer to the true transition temperature than the freezing points. The expanded uncertainty of melting temperature was calculated not to exceed $0.2^{\circ}C$ (k = 2). Based on the observed results, the melting process is recommended for the calibration of thermocouples.

온도구배 측정용 다중접점 열전대 (Multi-junction thermocouple for temperature gradient measurements)

  • 김용규;감기술
    • 센서학회지
    • /
    • 제4권2호
    • /
    • pp.3-6
    • /
    • 1995
  • 항온 유지 장치의 온도구배를 측정하기 위한 다중 접점을 갖는 K형 열전대를 제작하였다. 이 온도계를 사용하여 $800^{\circ}C$로 유지되고 있는 전기로의 온도구배를 측정하였으며, 교정용 기준기급의 S형 열전대와 비교한 결과 K형 열전대의 허용오차 범위 내에서 일치하였다. 더 정확한 온도구배 측정을 위해서는 귀금속 열전대를 사용하는 것이 바람직하다는 것을 제안하였다.

  • PDF

볼 엔드밀링에서 열전대를 이용한 절삭온도 측정법 (Measurement Technique of Cutting Temperatures Using Implanted Thermocouples in Ball End-Milling)

  • 이득우
    • 대한기계학회논문집A
    • /
    • 제24권7호
    • /
    • pp.1748-1752
    • /
    • 2000
  • In this paper, the measurement technique of cutting temperatures of shear zone using implanted thermocouples is proposed in ball end milling. K-type thermocouple implanted in the hole of workpieces is directly cut in order to measure temperatures of the shear zone in cutting process. Experiments are performed for a nickel based superalloy(Inconel 718) using a ball nose end mill. The results show that the cutting temperature in shear zone is about 3200C at the cutting speed of 90m/min with dry.

열전대 구조변화에 의한 열시정수 특성 변화 (Characteristics variation of thermal time constant of thermocouples by the structure changes)

  • 감기술
    • 센서학회지
    • /
    • 제18권2호
    • /
    • pp.103-109
    • /
    • 2009
  • Thermal time constant measurement system was designed and fabricated to measure the thermal time constant, which shows a dynamic property of the thermocouple. Type K thermocouple samples were fabricated with variable shape each other and the thermal time constants of thermocouples were measured using the home-made thermal time constant measurement system. Thermal time constants of 12 type K thermocouple samples were distributed from 0.03 s to 8.2 s. It showed experimentally that the thermal time constant of thermocouple was increased linearly for the increase of the sheath diameter of thermocouple.

쑥뜸과 1064 nm 파장의 근적외선 레이저로 가열된 아가젤 조직 팬텀 심부의 온도분포 가시화 (Visualization of Temperature Distribution Deep Inside the Agar Gel Tissue Phantom Heated Using Moxibustion and 1064 nm Infrared Laser)

  • 조지용;김중경
    • 한국가시화정보학회지
    • /
    • 제8권4호
    • /
    • pp.54-59
    • /
    • 2010
  • A laser moxibustion therapy device having effect similar to that of traditional moxibustion is being developed using 1064 nm infrared laser. The therapy device allows direct interaction of laser light with the tissue rendering temperature distribution both on the skin surface and deep under the skin. We made a device that could measure temperature of deep under the surface of agar gel tissue phantom using thermocouples. A thermal imaging camera was used to verify results from the temperature measurement device. We compared the characteristics of heat transfer inside the tissue phantom during moxibustion and laser irradiation. The temperature distribution measured by thermocouples was found to be similar to that of distribution given by thermal imaging camera.

CMOS 공정과 호환되는 마이크로머시닝 기술을 이용한 마이크로파 전력센서 (A CMOS Compatible Micromachined Microwave Power Sensor)

  • 이대성;이경일;황학인;이원호;전형우;김왕섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(1)
    • /
    • pp.439-442
    • /
    • 2002
  • We present in this Paper a microwave Power sensor fabricated by a standard CMOS process and a bulk micromachining process. The sensor consists of a CPW transmission line, a resistor as a healer, and thermocouple arrays. An input microwave heater, the resistor so that the temperature rises proportionally to the microwave power and tile thermocouple arrays convert it to an electrical signal. The sensor uses air bridged 8round of CPW realized by wire bonding to reduce tile device size and cost and to improve the thermal impedance. Al/poly-Si junctions are used for the thermocouples. Poly-Si is used for tile resister and Aluminium is for transmission line. The resistor and hot junctions of the thermocouples are placed on a low stress silicon nitride diaphragm to minimize a thermal loss. The fabricated device operates properly from 1㎼ to 100㎽\ulcorner of input power. The sensitivity was measured to be ,3.2~4.7 V/W.

  • PDF