• Title/Summary/Keyword: Thermosonic

Search Result 19, Processing Time 0.036 seconds

A Study on Thermosonic Bonding Process and Its Reliability Evaluation of Joints (열초음파 접합 공정과 접합부의 신뢰성 평가에 관한 연구)

  • Shin, Young-Eui;Pak, Jin-Suk;Son, Sun-Eik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.625-631
    • /
    • 2009
  • In this thesis, lateral thermosonic bonding with ACFs was investigated as a process to make high reliability joints for FPD fabrication. Conditions for thermosonic and thermocompression bonding with ACFs were determined and used to make specimens in a driving test jig for testing of bond reliability by thermal shock. The results showed that thermosonic bonding temperature of $199\;^{\circ}C$ and bonding time of 1s produced bonds with good reliability. Additionally, thermosonic bonding temperature and time were reduced and thermal shock test results compared to this proposed curing condition. It is concluded that theromosonic bonding with ACFs can be effectively applied to reduce bonding temperature and time compared with that of thermocompression bonding.

A Study on the Characteristics of the Excited Vibration Signals in a Thermosonic Test (초음파가진 열화장시험 시 가전된 진동 신호 특성 연구)

  • Kang, Bu-Byoung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.118-126
    • /
    • 2011
  • The characteristics of the responses obtained in thermosonic tests are investigated in this study to improve the performance of a thermosonic test system. Thermosonic tests are conducted with an acoustic horn with high power capability to investigate the characteristics of the vibration produced in turbine blades with complex geometry. The influences of the excitation signal that is input to the horn and the coupling methods between a clamp and the acoustic horn on the characteristics of the vibration excited in a component are presented. As a result, an excitation method with a fast narrow band chirp test (sweep test) and a stud coupling is proposed as an excitation method for thermosonic testing. This method can be applied to different types of turbine blades and also to other components.

Chip on Glass Interconnection using Lateral Thermosonic Bonding Technology (횡방향 열초음파 본딩 기법을 이용한 COG 접합)

  • Ha, Chang-Wan;Yun, Won-Soo;Park, Keum-Saeng;Kim, Kyung-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.7
    • /
    • pp.7-12
    • /
    • 2010
  • In this paper, chip-on-glass(COG) interconnection with anisotropic conductive film(ACF) using lateral thermosonic bonding technology is considered. In general, thermo-compression bonding which is used in practice for flip-chip bonding suffers from the low productivity due to the long bonding time. It will be shown that the bonding time can be improved by using lateral thermosonic bonding in which lateral ultrasonic vibration together with thermo-compression is utilized. By measuring the internal temperature of ACF, the fast curing of ACF thanks to lateral ultrasonic vibration will be verified. Moreover, to prove the reliability of the lateral thermosonic bonding, observation of pressured mark by conductive particles, shear test, and water absorption test will be conducted.

Performance of Different Sensors for Monitoring of the Vibration Generated during Thermosonic Non-destructive Testing

  • Kang, Bu-Byoung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.111-117
    • /
    • 2011
  • Vibration monitoring is required for reliable thermosonic testing to decide whether sufficient vibration is achieved in each test for the detection of cracks. From a practical point of view, a cheaper and convenient monitoring method is better for the application to real tests. Therefore, the performance of different sensors for vibration monitoring was investigated and compared in this study to find a convenient and acceptable measurement method for thermosonics. Velocity measured by a laser vibrometer and strain provide an equivalent HI when measured at the same position. The microphone can provide a cheaper vibration monitoring device than the laser and the heating index calculated by a microphone signal shows similar characteristics to that calculated from velocity measured by the laser vibrometer. The microphone frequency response shows that it underestimates high frequency components but it is applicable to practical tests because it gives a conservative value of HI.

Modeling of Soldering Proess using Longitudinal Thermosonic Method (종방향 열초음파 방법을 이용한 솔더링 공정의 모델링)

  • 김정호;이지혜;유중돈;최두선
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.224-227
    • /
    • 2003
  • The longitudinal thermosonic bonding method is investigated in this work for its application to the soldering process for electronic packaging. The effect of the ultrasonic is analyzed through lumped modeling, and the material properties of a viscoelastic model are measured experimentally. The thermosonic bonding method is verified by inserting the Cu pin and Au bump into solder block. As the solder thickness decreases, temperature of the solder is calculated to increase rapidly because of larger strain. Localized heating due to ultrasonic vibration is observed to melt the solder near the pin, which is adequate to the high density electronic package and Pb-free solder having high melting temperature.

  • PDF