• Title/Summary/Keyword: Three-Rods Test

Search Result 20, Processing Time 0.034 seconds

The Comparasion of the Dynamic Stereoacuity with Two-Rods Test and Three-Rods Test (이간계와 삼간계를 이용한 동적 입체시의 비교)

  • Shim, Hyun-Suk;Kim, Sang-Moon;Kim, Sang-Hyun;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.377-384
    • /
    • 2015
  • Purpose: On this study, we measured and compared the dynamic stereoacuity by two-rods test (Howard-Dolman Test) and three-rods test. And we analyzed the correlation between PD and refractive error with dynamic stereoacuity. Methods: Dynamic stereoacuity of two-rods test and three-rods test at 2.5 m distance for 93 adults 93 (50 males, 43 females), mean age of $21.27{\pm}2.32$ (19~32) years old, were measured 5 times for two tests. Results: The mean of dynamic stereoacuity measured by two-rods test and three-rods test were $29.91{\pm}23.03sec$ of arc and $23.75{\pm}21.65sec$ of arc for total subjects, respectively. The mean of male and female were $36{\pm}22.38sec$ of arc and $22.28{\pm}23.79$, respectively. Three-rods test showed better dynamic stereoacuity than two-rods test, but there was no statistically significant difference (p>0.05). For the average standard deviation of PD between 60.63 mm~66.19 mm, dynamic stereoacuity fo two-rod test and three-rod test were $31.48{\pm}24.87sec$ of arc and $31.48{\pm}24.87sec$ of arc, respectively. The results showed statistically significant difference (p<0.05), but the relationship between dynamic stereoacuity and PD was not great. Comparison between two tests on the basis of refractive error, dynamic stereoacuity by three-rods test was better than by two-rods test with no significant difference between both tests (p>0.05) and there was little correlation between refractive error and two dynamic stereoacuity. Conclusions: Three-rods test showing lower stereoacuity than two-rods tests could measure the lower minimum threshold of dynamic stereoacuity. It was found that both tests can be applied to dynamic stereoacuity test as a standard test, and PD and refractive error was found that little effect upon the dynamic stereoacuity. PD and refractive error was found that little effect upon the dynamic stereoacuity.

Shear Strength of Externally Post-Tensioned Concrete Beams (외부 포스트텐션 콘크리트 보의 전단강도)

  • Lee, Swoo-Heon;Kang, Thomas H.K.;Shin, Kyung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.1
    • /
    • pp.57-64
    • /
    • 2015
  • This paper shows the test results of continuous reinforced concrete beams with external post-tensioning rods. Six three-span beams were prepared and tested to fail. Three beams were designed to have flexure-dominating behavior and the others to have shear-critical behavior. In each group, one beam without external post-tensioning rods was designated as a control beam and two beams had the external post-tensioning rods of 18 mm or 22 mm diameter. External post-tensioning rods were installed within an interior span of 6000 mm. They show V-shaped configuration because two anchorages were located at the top of interior supports and a saddle pin at mid-span was installed at the bottom of the beam. Test results show that the load and shear capacities of strengthened beams were increased when compared with the control beam. Additionally, the measured shear strength was compared with the strength predicted by ACI 318-11 code equations. The detailed ACI 318-11 equation predicted the measured shear strength and failure location of the continuous beam reasonably well.

Comparison and Correlation between Distance Static Stereoacuity and Dynamic Stereoacuity (원거리 정적 입체시와 동적 입체시의 평가 및 상관관계)

  • Kim, Young-Cheong;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.385-390
    • /
    • 2015
  • Purpose: This study evaluated the static stereoacuity by Distance Randot Stereotest (STEREO OPTICAL. Co., Inc. USA) and the dynamic stereoacuity by three-rods test (iNT, Korea). Criterion and correlation of stereoacuity between both tests and usefulness of two stereotest methods were also evaluated. Methods: For normal adults of 109 (male 61, female 48), mean age of 20.88 (19-32 years) years old, static stereoacuity by using Distance Randot Stereotest at 3 m distance, dynamic stereoacuity by using three-rods test at 2.5 m distance were measured. Results: The mean of distance static stereoacuity was $155.77{\pm}133.11sec$ of arc and the mean of error distance dynamic stereoacuity $11.13{\pm}9.69mm$. With equivalent-conversion stereoacuity of $23.44{\pm}20.96sec$ of arc, there was statistically significant differences (p=0.00) between two dynamic stereoacuity, but correlation was relatively low (${\rho}=0.226$). In the case of dynamic stereoacuity, separated to normal range by criterion of the error distance 20 mm, it showed the error distance of less than 20 mm in 97 subjects(89%) whose average of error distance and conversion mean dynamic stereoacuity were $8.43{\pm}5.10mm$ and $17.68{\pm}10.67sec$ of arc. repectively. The error distance of was equivalent-conversion dynamic stereoacuity 40.99 sec of arc (PD 62 mm basis) was 20 mm. Conclusions: The results of lower correlation between static and dynamic stereoacuity suggest that seterotest should be applied separately to different functions. The results of this study also suggest that Distance Randot Stereotest can be applied to static stereoacuity excluding monocular cues. Three-rods test can be applied to dynamic stereoacuity containing the response of the eye-hand coordination in the daily life of natural vision condition, including the monocular cues. These different approaches canprovide a criterion of the two stereoacuity and parallel use of the two tests would be useful. For dynamic stereoacuity by three-rods test, error distance 20 mm in a normal range of adults can be used as a criteria to get statistical meaning of the results.

Changes of Dynamic Stereoacuity Depending on Distance between Rods and Rod Thickness in Three Rods Test (세막대 검사에서 막대 간 거리와 막대두께 차이에 의한 동적입체시력의 변화)

  • Han, Kyung-Do;Lee, Min-Jae;Kim, Sang-Yeob;Moon, Byeong-Yeon;Yu, Dong-Sik;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.253-257
    • /
    • 2016
  • Purpose: To determine whether the distance between objects and the size of object are factors to be able to affect dynamic stereoacuity. Methods: Subjects were 37 adults (26 males and 11 females) with an average age of $23.89{\pm}1.76$. Refractive error was fully corrected for all subjects and each visual acuity of them was over 0.9. Three rods test was performed for measurement of stereoacuity. The viewing angles from left rod to right rod were set $5^{\circ}$, $10^{\circ}$, and $15^{\circ}$ and the rod thickness used 7 mm, 14 mm, and 21 mm, respectively. Stereoacuity was repeatedly measured three times in each test condition at 2.5 m distance, and reported the average value of them. Results: When rod thickness was 7 mm or 14 mm, dynamic stereoacuity decreased as the viewing angle increased, and they were significantly decreased (p<0.01) at viewing angles of $10^{\circ}$ and $15^{\circ}$ as compared with that of at $5^{\circ}$, respectively. When rod thickness was 21 mm, dynamic stereoacuity decreased as the viewing angle increased, especially, that of at $15^{\circ}$ decreased significantly (p<0.01) as compared with that of at $5^{\circ}$. The dynamic stereoacuity depending on the rod thickness have an increasing tendency as the rod thickness increased. Conclusions: The viewing angle between objects and the size of viewing object were factors that affect to dynamic stereoacuity.

A Study on the Failure Behavior of the Reinforced Earth Wall Structures according to the Deformed Types of the Face (전면부 변형형태에 따른 보강토 벽체 구조물의 파괴거동에 관한 연구)

  • 김준석;이상덕
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.4
    • /
    • pp.167-173
    • /
    • 1999
  • In this paper the failure behavior of the reinforced earth retaining wall structures according to the deformed types of the face was studied by model test using carbon rods. In model test the behavior of the face for the model of the reinforced earth wall was divided into three cases : the displacement of the top part(case 1), the lateral displacement(case 2) and the displacement of the lower part (case 3). The photographic method was applied to examine the failure line of the deformed wall with the naked eye. The failure line shows a parabolic shape for case 1, a large circular arc for case 2 and a logarithmic spiral for case 3 in the experimental results. The design failure line for the coherent gravity structure hypothesis was most similar to the failure line for the case of the lower part displacement.

  • PDF

1D AND 3D ANALYSES OF THE ZY2 SCIP BWR RAMP TESTS WITH THE FUEL CODES METEOR AND ALCYONE

  • Sercombe, J.;Agard, M.;Struzik, C.;Michel, B.;Thouvenin, G.;Poussard, C.;Kallstrom, K.R.
    • Nuclear Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.187-198
    • /
    • 2009
  • In this paper, three power ramp tests performed on high burn-up Re-crystallized Zircaloy2 - UO2 BWR fuel rods (56 to 63 MWd/kgU) within the SCIP project are simulated with METEOR and ALCYONE 3D. Two of the ramp tests are of staircase type up to Linear Heat Rates of 420 and 520 W/cm and with long holding periods. Failure of the 420 W/cm fuel rod was observed after 40 minutes. The third ramp test consisted of a more standard ramp test with a constant power rate of 80 W/cm/min up to 410 W/cm with a short holding time. The tests were first simulated with the METEOR 1D fuel rod code, which gave accurate results in terms of profilometry and fission gas releases. The behaviour of a fuel pellet fragment and of the cladding piece on top of it was then investigated with ALCYONE 3D. The size and the main characteristics of the ridges after base irradiation and power ramp testing were recovered. Finally, the failure criteria validated for PWR conditions and fuel rods with low-to-medium burn-ups were used to analyze the failure probability of the KKL rodlets during ramp testing.

EFFECT OF POLYPHOSPHATE IN ROOT CANAL SEALERS ON THE GROWTH OF ORAL BACTERIA (Polyphosphate가 함유된 근관충전재가 구강세균의 성장에 미치는 영향)

  • 박석범;최기운;최호영
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.141-152
    • /
    • 2001
  • Eliminating the infecting bacteria of the root canal system and preventing reinfection must be the main objectives of all endodontic works. None of commercially available root canal sealers have the properties of desirable tissue compatibility and strong antibacterial activity. The purpose of this study is to develope an ideal root canal sealer using commercially available polyphosphate (polyP), Calgon, which is known to be antibacterial and safe. For the study. resin type AH26, zinc oxide eugenol type Tubli Seal. Ca(OH)$_2$ type Apexit as base sealers for polyP (0~3%) and para formaldehyde containing N2 as a control base were selected. Specimens (3$\times$4mm) of the sealers were prepared in a 37$^{\circ}C$ incubator for 3 and 10 days and their antibacterial activity against streptococci and black pigmented anaerobic rods was observed using an agar diffusion method. The result were as follows: 1. Among 3 day old root canal sealers. N2 as a positive control showed the strongest antibacterial effect. followed by AH26. Tubli Seal and. Apexit which barely showed antibacterial activity against the test bacteria. In contrast. 10 day old AH26 showed a greater antibacterial activity than 10 day old N2. 2. All sealer specimens showed a greater antibacterial activity against black pigmented anaerobic rods than streptococci. Three day old ones appeared to be more antibacterial than 10 day old ones except for Apexit. 3. As compared to N2, 3 day old AH26 demonstrated a similar antibacterial activity against black pig mented anaerobic rods but to a lesser extent to streptococci. Ten day old AH26 showed a greater antibacterial activity against black pigmented anaerobic rods than 10 day old N2. 4. As compared to AH26. Tubli Seal generally revealed a lower antibacterial activity but it showed a greater antibacterial activity aginst S. gordonii Challis. 5. Enhancement of antibacterial activity by polyP was more clearly observed when it was added to Ca(OH)$^{\circ}C$ based root canal sealers. Tubli Seal and N2. 6. The addition of polyP enhanced the antibacterial activity of 3 day old AH26 against S. gordonii G9B (16%) and Challis (29%), and P. gingivalis 2561 (24%) only. Moreover, polyP failed to increase antibacterial activity of 10 day old AH26 against the test strains but P. gingivalis A7A1 28(13%). 7. The addition of polyP increased the antibacterial effect of 3 day old Tubli Seal on several test bacteria including s. mutans GS 5 (50%). s. gordonii G9B (47%) and Challis (122%). and all the test strains of P. gingivalis (13~35%) except for 9 14K 1. The addition of polyP to 10 day old Tubli Seal increased antibacterial activity of the root canal sealer against most test strains. 8. 3 day old Apexit failed to show antibacterial activity. if any very little against S. mutans GS 5 and Pr. intermedia ATCC 49046. However. polyP increased its antibacterial activity by 50 and 69%, respectively. Increase of antibacterial activity of 10 day old Apexit by polyP was more clearly observed than that of 3 day old one.

  • PDF

Structural behavior of the stiffened double-skin profiled composite walls under compression

  • Qin, Ying;Li, Yong-Wei;Lan, Xu-Zhao;Su, Yu-Sen;Wang, Xiang-Yu;Wu, Yuan-De
    • Steel and Composite Structures
    • /
    • v.31 no.1
    • /
    • pp.1-12
    • /
    • 2019
  • Steel-concrete composite walls have been proposed and developed for applications in various types of structures. The double-skin profiled composite walls, as a natural development of composite flooring, provide structural and architectural merits. However, adequate intermediate fasteners between profiled steel plates and concrete core are required to fully mobilize the composite action and to improve the structural behavior of the wall. In this research, two new types of fasteners (i.e., threaded rods and vertical plates) were proposed and three specimens with different fastener types or fastener arrangements were tested under axial compression. The experimental results were evaluated in terms of failure modes, axial load versus axial displacement response, strength index, ductility index, and load-strain relationship. It was found that specimen with symmetrically arranged thread rods sustained more stable axial strain than that with staggered arranged threaded rods. Meanwhile, vertical plates are more suitable for practical use since they provide stronger confinement to profiled steel plate and effectively prevent the steel plate from early local buckling, which eventually enhance the composite action and increase the axial compressive capacity of the wall. The calculation methods were then proposed and good agreement was observed between the test results and the predicted results.

Critical Heat Flux in Uniformly Heated Rod Bundle Under Wide Range of System Pressures (광범위한 압력조건하에서 균일 가열 수직 봉다발에서의 임계열유속)

  • Moon, Sang-Ki;Chun, Se-Young;Choi, Ki-Yong
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.195-200
    • /
    • 2001
  • An experimental study on critical heat flux (CHF) has been performed for water flow in a uniformly heated vertical 3 by 3 rod bundle under low flow and a wide range of pressure conditions. The objective of this study is to investigate the parametric trends of CHF with 3 by 3 rod bundle test section where three unheated rods exist. The general trends of the CHF are coincident with previous understandings. At low flow and system pressure above 3 MPa, some critical qualities are larger than 1.0 due to counter-current flow in test sections. Since there is a supply of water to the heated section from unheated section, the maximum CHFs at system pressure between 2 and 4 MPa are not shown.

  • PDF

Relative Power Density Distribution Calculations of the Kori Unit 1 Pressurized Water Reactor with Full-Scope Explicit Modeling of Monte Carlo Simulation

  • Kim, Jong-Oh;Kim, Jong-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.375-384
    • /
    • 1997
  • Relative power density distributions of the Kori Unit 1 pressurized water reactor are calculated by Monte Carlo modeling with the MCNP code. The Kori Unit 1 core is modeled on a three-dimensional representation of the one-eighth of the reactor in-vessel component with reflective boundaries at 0 and 45 degrees. The axial core model is based on half core symmetry and is divided into four axial segments. Fission reaction density in each rod is calculated by following 100 cycles with 5,000 test neutrons in each cycle after starling with a localized neutron source and ten noncontributing settle cycles. Relative assembly power distributions are calculated from fission reaction densities of rods in assembly. After 100 cycle calculations, the system converges to a k value of 1.00039 $\geq$ 0.00084. Relative assembly power distribution is nearly the same with that of the Kori Unit 1 FSAR. Applicability of the full-scope Monte Carlo simulation in the power distribution calculation is examined by the relative root moan square error of 2.159%.

  • PDF