• Title/Summary/Keyword: Torsional Stiffness

Search Result 357, Processing Time 0.027 seconds

Development of a Finite Element Model for Evaluating Torsional Stiffness of the Frame of a Large Truck (대형트럭 프레임의 비틀림 강성 평가를 위한 유한요소 모델 개발)

  • Oh Chae-Youn;Moon Il-Dong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.4 s.235
    • /
    • pp.563-569
    • /
    • 2005
  • This paper develops a finite element model of a cabover type large truck. The finite element model is for evaluating torsional stiffness of the frame of the large truck. The torsional test of the frame is conducted in order to validate the developed finite element model. A load cell is used to measure the load applied to the frame. An angle sensor is used to measure the torsional angle. An actuator is used to apply a load to the frame. A vertical upward load and a vertical downward load are applied to the frame in the torsional test. The frame's torsional stiffness is computed with the measured load and torsional angle in the torsional test. The finite element model of the large truck includes cab, deck and payload, suspension, and tire. Cab, deck, and suspension are modeled not to affect the frame's torsional stiffness. The simulation is performed with the developed finite element model for evaluating the frame's torsional stiffness. The simulation results show a very good correlation with the torsional test results in the tendency of changing of the frame's torsional stiffness not only with the direction of the applying load but also with the amount of the applying load. In addition, the simulation results predict the measured torsional stiffness of the frame with about $5{\%}$ error.

Torsional Stiffness Analysis of a Cycloid Reducer using Hertz Contact Theory (Hertz 접촉이론을 이용한 사이클로이드 감속기의 비틀림 강성해석)

  • Lee S.Y.;Park J.S;Ahn H.J.;Han D.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.816-821
    • /
    • 2005
  • The cycloid reducer has very high efficiency, high ratios, high stiffness and small size, in comparison with a conventional gear mechanism, which makes it an attractive candidate for limited space and precision application such as industrial robot. There are several publications on analysis and design of the cycloid reducer, however, it was assumed that the contact stiffness of pin rollers and cycloid disk is constant regardless of their contact geometry. Moreover, the torsional stiffness of the cycloid reducer couldn't be calculated due to the assumption. In this paper, we present a new procedure of calculating torsional stiffness of the cycloid reducer using Hertz contact theory. First, conventional force analysis of the cycloid reducer is briefly reviewed. Then, iterative numerical calculation procedure of the contact stiffness is proposed based on the Hertz contact theory where the contact stiffness depends on the contact force. In addition, total torsional stiffness of the cycloid reducer is estimated considering its rolling element bearing stiffness. The torsional stiffness of the cycloid reducer is dominated by the rolling element bearing stiffness since the contact stiffness of the cycloid disk is too large.

  • PDF

Digital Optimal Contorl of Servomotor System Considering Torsional Vibration Characteristics (비틀림 진동특성을 고려한 서어보모터계의 디지털 최적제어)

  • Jo, Seung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.6 no.4
    • /
    • pp.52-60
    • /
    • 1989
  • In order to control the transient torsional vibration of rotational shaft system, the torsional stiffness of it has been taken into account in modelling the plant. In this paper the observer and controller has been designed in two ways. One is to consider the torsional stiffness and the other is to idealize the rotational shaft as rigid body. The third order observer considering torsional stiffness shows stable response on computer simulation. When the observer is designed on assumption of the rotational shaft being rigid body, the reduced order observer shows stable response whereas the full order observer shows unstable response.

  • PDF

Sensitivity Analysis for Natural Frequency of Torsional Shafting with Constant Cross Section Using Transfer of Stiffness Coefficient (강성계수의 전달을 이용한 일정 단면을 갖는 비틀림 축계의 고유진동수 민감도 해석)

  • Choi, Myung-Soo;Byun, Jung-Hwan
    • Journal of Power System Engineering
    • /
    • v.16 no.2
    • /
    • pp.11-16
    • /
    • 2012
  • In this paper, the authors formulate the sensitivity analysis algorithm for the natural frequency of a torsional shafting by expanding the transfer stiffness coefficient method. The basic concept of the present algorithm is based on the transfer of sensitivity stiffness coefficient, which is the derivative of stiffness coefficient with respect to design parameter, at every node from the first node to the last node in analytical model. The effectiveness of the present algorithm is confirmed by comparing the results of the sensitivity analysis and those of the reanalysis for the natural frequencies of a torsional shafting with a constant cross section. In numerical calculation, the design parameter is the diameter of the shaft element of the torsional shafting.

Postcracking Torsional Stiffness of Reinforced Concrete Beams under Pure Torsion (순수비틀림을 받는 철근콘크리트 보의 균열후 비틀림 강성)

  • 음성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.10a
    • /
    • pp.51-58
    • /
    • 1991
  • In staically indeterminate structures torsional stiffness is an important factor for prediction of mechanical behavior at all loading stages in reinfored concrete beams, which also for calculation of torsional moment. This paper proposes equation for postcracking torsional stiffness of reinforced concrete beams under pure torsion, which is derived considering the equilibrium and compatibility condition for shear panel based on the variable angle space truss model. The equation describes well the effect according to the variation of aspect ratio and steel volume ratio per unit concrete volume. It agress with experimental results in this paper as well as available literature.

  • PDF

An optimized torsional design of asymmetric wall structures (비대칭 벽식구조의 최적 비틀림 설계)

  • 조봉호;홍성걸
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.327-334
    • /
    • 2002
  • This paper develops an optimized torsional design method of asymmetric wall structures considering deformation capacities of walls. Contrary to the current torsional provisions, a deformation based torsional design is based on the assumption that stiffness and strength are dependent. Current torsional provisions specify two design eccentricity of stiffness to calculate the design forces of members. But such a methodology leads to an excessive over-strength of some members and an optimal torsional behavior is not ensured. Deformation-based torsional design uses displacement and rotation angle as design parameters and calculates base shear for inelastic torsional response directly. Because optimal torsional behavior can be defined based on the deformation of members, deformation based torsional design procedure can be applied to the optimal and performance-based torsional design. To consider the effect of accidental eccentricity, an over-strength factor is defined. The over-strength factor is determined from performance level, torsional resistance and arrangement of walls.

  • PDF

Effects of coupled translational-torsional motion and eccentricity between centre of mass and centre of stiffness on wind-excited tall buildings

  • Thepmongkorn, S.;Kwok, K.C.S.
    • Wind and Structures
    • /
    • v.5 no.1
    • /
    • pp.61-80
    • /
    • 2002
  • Wind tunnel aeroelastic model tests of the Commonwealth Advisory Aeronautical Research Council (CAARC) standard tall building were conducted using a three-degree-of-freedom base hinged aeroelastic(BHA) model. Experimental investigation into the effects of coupled translational-torsional motion, cross-wind/torsional frequency ratio and eccentricity between centre of mass and centre of stiffness on the wind-induced response characteristics and wind excitation mechanisms was carried out. The wind tunnel test results highlight the significant effects of coupled translational-torsional motion, and eccentricity between centre of mass and centre of stiffness, on both the normalised along-wind and cross-wind acceleration responses for reduced wind velocities ranging from 4 to 20. Coupled translational-torsional motion and eccentricity between centre of mass and centre of stiffness also have significant impacts on the amplitude-dependent effect caused by the vortex resonant process, and the transfer of vibrational energy between the along-wind and cross-wind directions. These resulted in either an increase or decrease of each response component, in particular at reduced wind velocities close to a critical value of 10. In addition, the contribution of vibrational energy from the torsional motion to the cross-wind response of the building model can be greatly amplified by the effect of resonance between the vortex shedding frequency and the torsional natural frequency of the building model.

A Study on Torsional Stiffness Improvement of a Vehicle (자동차의 비틀림 강성 향상에 관한 연구)

  • 임기창;임석현
    • Fire Science and Engineering
    • /
    • v.11 no.1
    • /
    • pp.47-54
    • /
    • 1997
  • Using high tensile steel plate makes the vehicle body stiffness lower even though it can lessen the fuel consume rate in application of weight reduction. The crack which happens arround vehicle window glass is brought about due to fatigue with low torsional stiffness. The paper presents a most suitable way to increase torsional stiffness using elasticity theory. Also the result of this study shows good agreement with FEM and experiments. We used a passenger car for calculation in this paper. Because we can apply the result of this study to fire engine as well as passenger car.

  • PDF

I-girder with Discrete Torsional Bracing: Lateral-torsional Buckling and Torsional Free Vibration (I-거더 불연속 비틀림 브레이싱: 횡-비틂 좌굴 및 비틀림 자유진동)

  • Nguyen, Cahn Tuan;Moon, Ji-Ho;Kim, Hyun-Soo;Lee, Hak-Eun
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.85-85
    • /
    • 2010
  • Discrete torsional bracing systems are widely used in practice to increase the strength of I-girders bridges. This paper proposes equations for lateral-torsional buckling strength, torsional natural frequency and stiffness requirements of I-girders with discrete torsional bracings. Firstly, the equations to calculate the critical moment of the I-girder with discrete torsional bracings are introduced. The proposed equations are then compared with the results of finite element analyses and those from previous studies. The equations to calculate the torsional natural frequency are also presented in the same manner. From the results, it is found that proposed equations agree well with results of finite element analyses regardless of the number of bracing points. Finally, the reduced formula for the total torsional stiffness requirement is proposed for the design purpose.

  • PDF

Effective torsional stiffness of reinforced concrete structural walls

  • Luo, Da;Ning, Chaolie;Li, Bing
    • Earthquakes and Structures
    • /
    • v.16 no.1
    • /
    • pp.119-127
    • /
    • 2019
  • When a structural wall is subjected to multi-directional ground motion, torsion-induced cracks degrade the stiffness of the wall. The effect of torsion should not be neglected. As a main lateral load resisting member, reinforced concrete (RC) structural wall has been widely studied under the combined action of bending and shear. Unfortunately, its seismic behavior under a combined action of torsion, bending and shear is rarely studied. In this study, torsional performances of the RC structural walls under the combined action is assessed from a comprehensive parametrical study. Finite element (FE) models are built and calibrated by comparing with the available experimental data. The study is then carried out to find out the critical design parameter affecting the torsional stiffness of RC structural walls, including the axial load ratio, aspect ratio, leg-thickness ratio, eccentricity of lateral force, longitudinal reinforcement ratio and transverse reinforcement ratio. Besides, to facilitate the application in practice, an empirical equation is developed to estimate the torsional stiffness of RC rectangular structural walls conveniently, which is found to agree well with the numerical results of the developed FE models.