• Title/Summary/Keyword: Train Voltage Condition

Search Result 27, Processing Time 0.033 seconds

A study on the Hazard analysis and Improving methods for an Electrical shock on the Platform (전철 고상홈 전기통전 위험요인 분석 및 대책 연구)

  • Wang Jong-Bae;Cho Yuen-Oak
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.258-262
    • /
    • 2004
  • In this paper, the hazard factors on voltage rising effect between the rail and the earth were reviewed in subway system of AC traction line according to moving condition and location of the train. Site measuring of voltage rising between conductor part of train and station floor was performed to ascertain the risk level on the passenger. Plans for preventing hazard of rail-voltage rising and electrical shock on the passengers at platform were proposed.

  • PDF

Modeling and Simulation Reactive Power Compensator using Multi-port Network Algorithm in Electrified Railway (다단자망 알고리즘을 이용한 급전시스템의 무효전력 보상 모델링 및 시뮬레이션)

  • Kim, Joorak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.883-887
    • /
    • 2016
  • The power supply system in Korean electrified railway has adopted AT feeding. If a fault occurs in some substation for any reason, the vicinity substation must feed electric power on the outage substation through catenary. So, the feeding distance grows twice of the normal state at extended feeding condition. If substation's feeding distance is longer than normal condition, the catenary impedance and train to supply electric power from the substation. Therefore, the severe voltage drop can occur and power supply shall be not allowed. This paper presents the model of compensator against voltage drop using multi-port network algorithm. Whole traction power supply system can be analyzed with this model. Computer simulation including this model is performed based on real train schedule and increased schedule in case studies.

Acceleration Life Prediction of the Capacitor on a Traction Inverter for a High-Speed Train (고속철도차량용 견인 인버터 커패시터의 가속수명 예측)

  • Maeng, Heeyoung;Jung, Si-Kyo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.6
    • /
    • pp.653-659
    • /
    • 2015
  • The aim of this study is to develop a technique for the accelerated life test of the capacitor in a propulsion control device of a traction inverter used for a high-speed train. Using this technique, the accelerated life test can possibly estimate the life cycle of a capacitor under various temperature conditions and irregularly applied voltage. The accelerated life test is conducted for the capacitor of the traction inverter. The common proceedings of this test are selection of failure mechanism, determination of accelerated stress, range determination of the accelerated stress, determination of the test condition, and distribution and determination of the sample. From this result, the continuous applied voltage was not considered for the acceleration factors anymore. Therefore, the final result having an acceleration factor of 9.4 (= 13,626/1,445) was observed. Furthermore, the life-shortening acceleration effect for the irregular applied voltage condition can be applied to various situations.

A Study on Verification of PowerRail based on Voltage Drop under Extended Feeding Condition (연장급전 전압강하 계산을 위한 전기철도 급전 시뮬레이터의 검증에 관한 연구)

  • Kim, Joorak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.331-337
    • /
    • 2015
  • The power flow analysis of electrified railway is required complicated calculation, because of variable load. Train runs trough rail supplied by electric power therefore, the load value in electrified railway system fluctuates along time. The power flow algorithm in electrified railway system is different from general power system, and the power flow simulation is peformed by the particular simulation software. Powerail is simulation software for analysis of traction power supply system developed by KRRI, in 2008. This consists of load forecasting module, including TPS and time scheduling, and power flow module. This software was verified by measured current under normal feeding condition, however, has not been verified by voltage on the condition of extended feeding. This paper presents the verification of PowerRail based on voltage drop under extended feeding condition. This is performed by comparing simulation result with field test. Field test and simulation is done in commercial railway line.

A study on technical application of recycle energy storage system for electric rail car (전동차 회생에너지 활용을 위한 저장시스템 적용기술 연구)

  • Kim, Gil-Dong;Lee, Han-Min;Oh, Se-Chan;Lee, Chang-Mu
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.307-309
    • /
    • 2006
  • There are operated the six thousand train in the interior of a country. 95% of them are possible usage of resuscitation. Especially, Among them VVVF-Inverter vehicle has a merit of the highest recycle rate. but we don't use a apt recycled energy. Although the existing recycle energy used inverter method supply with electric power, it is decided in accordance with the state of sources. So efficiency of recycled electric power is of poor quality and catenary-voltage-fluctuation be generate because of recycled electric power. and it is able to affect system of safety train service. We'll research the method of supply according to wire condition after storing recycle energy made during train's stopping relation to Advanced EMU Research. Those methods are divided SMES, Fly-Wheel and Supercapacitor, and Considering the both economical efficiency and system application, we'll develop recycle energy storage system suitable our country condition.

  • PDF

Development of recycle energy storage system on electric rail car (전동차 회생 에너지 저장 시스템 개발에 관한 연구)

  • Kim Gil-dong;Kim Jong-Dae;Lee Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.660-664
    • /
    • 2005
  • There are operated the six thousand train in the interior of a country, $95\%$ of them are possible usage of resuscitation, Especially, Among them VVVF-Inverter vehicle has a merit of the highest recycle rate, but we don't use a apt recycled energy. Although the existing recycle energy used inverter method supply with electric power, it is decided in accordance with the state of sources. So efficiency of recycled electric power is of poor quality and catenary-voltage-fluctuation be generate because of recycled electric power. and it is able to affect system of safety train service. We'll research the method of supply according to wire condition after storing recycle energy made during train's stopping relation to Advanced EMU Research. Those methods are divided SMES, Fly-Wheel and Supercapacitor. and Considering the both economical efficiency and system application, we'll develop recycle energy storage system suitable our country condition.

  • PDF

A Study on the Static Var Compensator Application for Compensating the Train Garage's Unbalanced Voltages in Korean National Railroad (전동차 사무소의 전압불평형 보상을 위한 SVC 적용에 관한 연구)

  • Lee, Jun-Kyong;Lee, Seung-Hyuk;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.81-89
    • /
    • 2004
  • AC electric railroad system receives its power from 3-phase transmission system. Since trainloads are moving continuously, the voltages for the single load fluctuate in the train garage, and moreover, the fluctuating voltages generate high-order harmonics. This means the difficulty in maintaining power quality in the power system. Therefore, in this paper, the adequacy of SVC application is investigated for the train garage in KNR(Korean National Railroad). Voltage drop, voltage regulation, and unbalanced voltages are assessed in the train garage for the condition of power system both with svc and without SVC. In this paper, PSCAD/EMTDC is used for the above assessment items, and the results are compared with ones which was already designed in the field in practice for the train garage. As a result, the train garage using SVC improves power quality.

A Power Losses Analysis of AC Railway Power Feeding Network using Adaptive Voltage Control (능동형 전압제어를 통한 교류 전기철도 급전망에 대한 전력손실 분석)

  • Jung, Hosung;Kim, Hyungchul;Shin, Seongkuen;Kim, Jinho;Yoon, Kiyong;Cho, Yonghyeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1621-1627
    • /
    • 2013
  • This paper compares power losses between voltage controlled before and after using power conversion device in AC feeding system. For this purpose we present voltage control procedures and criteria and model high speed line and train using PSCAD/EMTDC to compare power losses in various feeding condition. Power losses of the simulation result in power control before and after in single point feeding system was reduced maximum 0.37 MW(23.8 %) and average 0.23 MW(20.5 %) when one vehicle load operates maximum load condition. When three vehicles operate maximum load condition in one feeder section, power losses after voltage control was reduced 1.03 MW(49.5%) compared to before voltage control. And, power loss of parallel feeding system is reduced the average 0.08 MW(7.2 %) compared to the single feeding system. In conclusion, adaptive voltage control method using power conversion device can reduce power losses compared with existing method.

The Service Voltage Measurement and Analysis while TTX Runs (틸팅열차 운행 중 가선전압 계측 및 분석연구)

  • Lee, Su-Gil;Kang, Chul;Her, Jae-Sern;Kim, Jae-Chul;Lim, Jae-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.58-65
    • /
    • 2009
  • Recently, the Korea Tilting Express(TTX), "HANVIT 200", KRRI(Korea Railroad Research Institute) developed runs for test on the conventional railroad, Honam line, Center line, Chunk-buk line and Tae-baek line. In this paper, we measured the service voltage while TTX ran on the conventional railroad and analyzed the condition of voltage. For measuring voltage directly, we installed PT under the pantograph and measured the voltage of the primary winding. In addition, we record situations that other trains pass by TTX and environments while TTX ran. And then we analyzed the condition of voltage using the records and CBEMA curve. In result, over 110[%] voltage of rated voltage(25[kV]) often occurred and the voltage of some place continued over 110[%] for about 200[s]. Especially, the voltage condition of Tae-baek line is the worst. The results in this paper can help to stabilize the power device and power converter of TTX.

Development of the Traction Motor for High Speed Train (한국형 고속전철용 견인전동기 개발)

  • 이상우;윤종학;최종묵;박계서
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.427-433
    • /
    • 2002
  • An inverter-driven induction motor is usually adapted to the traction motor for a high speed drive system requiring safety, reliability, performance, compact size owing to the space and weight alloted for attaching to train, etc. and AC Traction motor for G7 train will be operated in the worst condition such as mechanical vibration, limited mounting space, severe thermal stress, inverter with non-sinusoidal voltage waveform, dust and so on. therefore, design procedure must be carefully carried out wi th considering the motor size, vibration and thermal expansion of rotor bars, insulation system, reliability of frame, as well as output characteristics. In this paper, we will inform the characteristics and design of the traction motor for G7 train and also analyze the test result of it.

  • PDF