• 제목/요약/키워드: Transfer stability

검색결과 952건 처리시간 0.025초

Assessment of Total Transfer Capability Using IPLAN: An Application of UPFC for Total Transfer Capability Enhancement

  • Lee Byung Ha;Kim Jung-Hoon;Kwak No-Hong;Lee Woon-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.244-251
    • /
    • 2005
  • Power transfer capability has been recently highlighted as a key issue in many utilities. It is determined by the thermal stability, dynamic stability and voltage stability limits of generation and transmission systems. In particular, voltage stability affects power transfer capability to a great extent in many power systems. This paper presents a tool for determining total transfer capability from a static voltage stability viewpoint using IPLAN, which is a high level language used with the PSS/E program. The tool was developed so as to analyze static voltage stability and to determine the total transfer capability between different areas from a static voltage stability viewpoint by tracing stationary behaviors of power systems. A unified power flow controller (UPFC) is applied for enhancing total transfer capability between different areas from the viewpoint of static voltage stability. Evaluation of the total transfer capability of a practical KEPCO power system is performed from the point of view of static voltage stability, and the effect of enhancing the total transfer capability by UPFC is analyzed.

전체송전용량 향상을 위한 STATCOM 설비의 적용 위치 선정 및 과도안정도를 고려한 전체송전용량 분석 (A Study on Location of STATCOM for Improvement of Total Transfer Capability and Analysis of Total Transfer Capability Considering Transient Stability)

  • 이병하;백정명
    • 조명전기설비학회논문지
    • /
    • 제24권4호
    • /
    • pp.17-24
    • /
    • 2010
  • 송변전설비들이 점점 중부하로 운용되어짐에 따라 송전용량이 전력회사에서 중요한 문제로 부각되어 왔다. 한전 시스템의 경우 전체송전용량은 주로 전압 안정도에 의해 제한을 받고 있으며, 이의 향상을 위한 연구들이 계속하여 수행되어 오고 있다. 본 논문에서는 전압안정도 관점에서의 전체송전용량을 향상시키기 위하여 STATCOM 설비를 설치하는 위치를 효과적으로 선택하기 위한 송전용량지수가 제시된다. 이 지수를 소규모 전력시스템인 IEEE 39모선 시스템에 적용하여 제시된 지수의 효과를 보여준다. 그리고, 이 소규모 시스템을 활용하여 부하가 증가할 때 전체송전용량에 전압안정도뿐 만이 아니라 과도안정도가 미치는 영향을 분석한다.

MAG용접의 Arc안정성에 미치는 Si의 영향 (Effect of Si on Arc Stability of MAG Welding)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • 제16권6호
    • /
    • pp.52-58
    • /
    • 1998
  • The effect of Si content in welding wires on th arc stability was investigate, in the region of short circuit transfer and spray transfer. In the region of short circuit transfer, with increasing Si content, average arcing time and average short circuit time were increased. Therefore, droplet transfer frequency was decreased, due to the increase of arcing time and peak current at the moment of arc-reiginition was increased, due to the increase of short circuit time. In the region of spray transfer, the fluctuations of arc current and arc voltage was the most stable in wire with Si content of about 00.60 wt.%.

  • PDF

MAG용접의 Arc안정성에 미치는 S의 영향 (Effect of S on Arc Stability of MAG Welding)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • 제17권1호
    • /
    • pp.55-61
    • /
    • 1999
  • The effect of S content in welding wires on the arc stability was investigated, in the region of short circuit transfer and spray transfer. In the region of short circuit transfer, with increasing S content, average arcing time and average short circuit time were decreased. Therefore, droplet transfer frequency was increased, due to the reduction of arcing time and peak current at the moment of arc-reiginition was decreased, due to the decrease of short circuit time. In the region of spray transfer, the fluctuation degree of arc current and arc voltage became more stable, with increasing S content.

  • PDF

GMAW에서 와이어 송급속도의 변동이 아크안정성에 미치는 영향에 관한 연구 (Effects of Wire speed Fluctuation on Arc Stability in GMA Welding)

  • 신현욱;최용범;성원호;장희석
    • Journal of Welding and Joining
    • /
    • 제13권4호
    • /
    • pp.85-102
    • /
    • 1995
  • Weld quality of GMA welding processes is closely related to arc stability. Although many researches on arc stability have been performed, real-time estimation of arc stability has not been attempted. For instance, Mita proposed a off-line statistical method in which short circuiting and arcing time, and voltage and current wave forms were sampled to assess arc stability. But this method is not suitable to assess arc stability for GMA welder which employ inverter power source due to its controlled current and voltage wave forms. In this paper, the relationship between are stability and wire feed rate fluctuation is analyzed to propose new criterion for inverter power source. When arc voltage and arc current and arcing time are analyzed, we can assess arc stability only for short circuit transfer mode. When wire feed rate is analyzed, we can estimate arc stability udner the condition of spray transfer mode as well. Hence, the wire feed rate is chosen for monitoring process variable to cover possible metal transfer modes in GMAW. Through this research, it has been identified that arc stability in GMA welding processes is closely related to wire fed rate. When inverter power source is used, conventional statistical method of estimating arc stability, such as Mita index, is no longer valid due to its controlled voltage and current wave forms. Arc stability has been also examined in phase plane diagram.

  • PDF

Calculation of Active Power Transfer Capability using Repeated Power Flow Program

  • Ham, Jung-Pil;Kim, Jung-Hoon;Lee, Byung-Ha;Won, Jong-Ryul
    • KIEE International Transactions on Power Engineering
    • /
    • 제12A권1호
    • /
    • pp.15-19
    • /
    • 2002
  • The power transfer capability is determined by the thermal, dynamic stability and voltage limits of the generation and transmission systems. The voltage stability depends on the reactive power limit and it affects the power transfer capability to a great extent. Then, in most load flow analysis, the reactive power limit is assumed as fixed, relatively different from the actual case. This paper proposes a method for determining the power transfer capability from a static voltage stability point of view using the IPLAN which is a high level language used with PSS/E program. The f-V curve for determining the power transfer capability is determined using Repeated Power Flow method. It Is assumed that the loads are constant and the generation powers change according to the merit order. The maximum reactive power limits are considered as varying similarly with the actual case and the effects of the varied maximum reactive power limits to the maximum power transfer capability are analyzed using a 5-bus power system and a 19-bus practical power system.

전체송전용량 결정을 위한 전압안정도 측면에서의 상정사고 순위 매김 (Contingency Ranking for Determining Total Transfer Capability from Voltage Stability Point of View)

  • 이병하;백정명
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.148-154
    • /
    • 2008
  • 송전용량산정은 최근에 많은 전력회사에서 중요한 문제로 부각되어 왔다. 한전 시스템의 경우 전체송전용량은 주로 전압 안정도에 의해 제한을 받고 있으며, 전체송전용량 산정을 위하여서는 수많은 상정사고들에 대해서 분석하여야 한다. 따라서 전체송전용량 결정을 위한 전압안정도 측면에서의 상정사고를 효과적으로 선정하는 기법이 절실히 요청되고 있으며, 본 논문에서는 전체송전용량 결정을 위한 전압안정도 측면에서의 상정사고를 효과적으로 선정하는 새로운 상정사고 선정지수를 제시한다. 그리고 이 전체송전용량 결정을 위한 전압안정도 측면에서의 상정사고 선정지수의 효율성을 검증하기 위해 이 지수를 한전의 실계통에 적용하고 PSS/E 패키지와 개발한 IPLAN 프로그램을 사용하여 이 지수의 상정사고 선정에 대한 효용성이 분석된다.

전압 안정도 제약계통에 대한 고온초전도 케이블 적용효과 (Effects of HTS Cable Applied to the Voltage Stability Limited Power System)

  • 이근준;황시돌
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.169-173
    • /
    • 2004
  • 본 논문은 전력계통의 전압 안정도 제약 문제를 해결하는데 고온 초전도 케이블을 적용하기 위한 기법을 제시하였다. 대전력계통의 유효 송전용량은 종종 전압 안정도 제약에 의해 결정된다. 기존의 초전도 케이블 응용 연구는 주로 도심지역의 고밀도 전력 수송 문제를 해결하는 대안으로 연구의 초점을 두어왔지만, 고온 초전도 케이블의 선로정수 개선효과를 이용하면 전압 안정도로 제약된 계통의 송전용량을 증가시킬 수 있어 그 응용 범위가 확대될 수 있다. 전압 안정도에 의한 최대 수송전력을 결정하는 데는 IPLAN에 의한 P-V곡선을 이용하였고, 대체 대상선로는 부하 증가시 무효전력 손실감도가 가장 큰 선로로 하였다. 결과의 타당성을 검증하기 위해 IEEE 14모선 계통을 사용하였으며, 적용결과 Case II는 70[%], Case III에서는 160[%]의 추가 수송 능력 증가를 가져올 수 있었다.

과도 안정도를 고려한 총 송전용량 평가 (Assessment of Total Transfer Capability Considering Transient Stability)

  • 박진욱;배인수;김진오;김규호
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.94-99
    • /
    • 2005
  • 본 논문은 기존의 총 송전용량 결정에 있어서 고려하기 어려웠던 과도 안정도 제약을 판별법을 적용하기 위해 2단계 계산 기법을 이용하여 보다 용이하게 적용하였다. 총 송전용량을 계산하기 위한 방법으로 첫 번째 단계에서는 RPF(Repeated Power Flow) 방법을 이용하여 전압과 열적한계를 판별하고, 두 번째 단계에서는 첫 번째 단계에서 결정된 총 송전용량이 시스템의 과도 안정도 조건의 위반여부를 판별하여 시스템의 총 송전용량을 결정하였다.

에너지함수법을 이용한 가용송전용량(ATC) 계산에 관한 연구 (A study on the ATC(Available Transfer Capabilily) calculation using an Energy Function Method)

  • 김재현;정성원;김양일
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.94-100
    • /
    • 2008
  • 가용송전용량(ATC)은 계통내의 한 지역에서 다른 지역까지 실제 전력을 증가시키는 것이다. 지금까지 ATC 계산은 대부분 정상상태에서 실행가능성을 주로 고려하여 계산되어 왔다. 하지만 ATC 평가시 과도안정도로 제약된 ATC 계산은 매우 중요한 부분이다. ATC 평가시에는 제약조건으로 열적용량, 전압 및 과도안정도로 제약된 상정사고(n-1)시 안전도 평가가 요구된다. 본 논문은 자코비안 행렬의 고유치를 이용하여 상정사고 우선순위를 선정하였고, 에너지 함수법을 이용하여 선로의 열적용량, 전압안정도 및 과도안정도를 고려한 ATC를 계산하였다.