• 제목/요약/키워드: Transfer stability

검색결과 952건 처리시간 0.037초

Reduced Order Identification and Stability Analysis of DC-DC Converters

  • Ali, Husan;Zheng, Xiancheng;Wu, Xiaohua;Zaman, Haider;Khan, Shahbaz
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.453-463
    • /
    • 2017
  • This paper discusses the measurement of frequency response functions for various dc-dc converters. The frequency domain identification procedure is applied to the measured frequency responses. The identified transfer functions are primarily used in developing behavioral models for dc-dc converters. Distributed power systems are based upon such converters in cascade, parallel and several other configurations. The system level analysis of a complete system becomes complex when the identified transfer functions are of high order. Therefore, a certain technique needs to be applied for order reduction of the identified transfer functions. During the process of order reduction, it has to be ensured that the system retains the dynamics of the full order system. The technique used here is based on the Hankel singular values of a system. A systematic procedure is given to retain the maximum energy states for the reduced order model. A dynamic analysis is performed for behavioral models based on full and reduced order frequency responses. The close agreement of results validates the effectiveness of the model order reduction. Stability is the key design objective for any system designer. Therefore, the measured frequency responses at the interface of the source and load are also used to predict stability of the system.

A Combustion Instability Analysis of a Model Gas Turbine Combustor by the Transfer Matrix Method

  • Cha, Dong-Jin;Kim, Jay-H.;Joo, Yong-Jin
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2946-2951
    • /
    • 2008
  • Combustion instability is a major issue in design of gas turbine combustors for efficient operation with low emissions. Combustion instability is induced by the interaction of the unsteady heat release of the combustion process and the change in the acoustic pressure in the combustion chamber. In an effort to develop a technique to predict self-excited combustion instability of gas turbine combustors, a new stability analysis method based on the transfer matrix method is developed. The method views the combustion system as a one-dimensional acoustic system with a side branch and describes the heat source as the input to the system. This approach makes it possible to use the advantages of not only the transfer matrix method but also well-established classic control theories. The approach is applied to a simple gas turbine combustion system to demonstrate the validity and effectiveness of the approach.

  • PDF

비함침 초전도마그네트의 과도안정성 (Transient Stability in Dry-winding Superconducting Magnets)

  • 김석범;석산돈사;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.89-91
    • /
    • 1996
  • In dry-winding(unfilled) superconducting magnets, the behavior of liquid helium occupying the extremely small void space within the winding is contributed as a primary factor for transient stability of magnets. Therefore, numerical experiments have been carried out concerning the influences of transient heat transfer of liquid helium ocupying the void space in the winding and thermal properties of insulation at the conductor surface on the transient stability of magnets, by using three-dimensional finite element method(FEM). In this paper, we are going to consider three different cases for heat transfer characteristics of liquid helium to observe the influences of the rest of liquid helium in void space within the winding on the transient stability.

  • PDF

Characteristics of Stability and Intensity of Vertical Transfer in the Western Channel of the Korea Strait

  • Chung, Jong Yul
    • 한국해양학회지
    • /
    • 제10권2호
    • /
    • pp.57-66
    • /
    • 1975
  • Structure of thermocline, characteristics of stability and intensity of vertical transfer have been studied with hourly oceanographic data in each layers on Line 207 from 1968 to 1969. It is found that a typical thermocline is formed at depths of 10 to 50 meters in summer and early autumn and its core is located near depths of 25 meters. The maximum diffusion coefficient of vertical turbulent is found to be 140$\textrm{cm}^2$/sec at the surface layer(i.e., 0-10 meters), while the minimum is 5$\textrm{cm}^2$/sec at depths of 25 meters, consistent with characteristics of stability and structure of thermocline layers. Our computed diffusion coefficient and stability indicate that the mixing hardly takes place below depths of 80 meters during summer and early autumn, but for the rest of the season mixing could move up to the depth of 50 meters. It appears that the Western Channel of the Korea Strait consist of three different water masses during summer and autumn, and for the rest of the season, two kinds are present.

  • PDF

CIC 초전도 도체의 안정성 (Stability of the Cable-in-Conduit Conductors)

  • 류경우
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권9호
    • /
    • pp.895-900
    • /
    • 1997
  • A Quench in cable-in-conduit (CIC) conductors is often initiated by a disturbance such as strand motion that generates a highly localized normal zone in a strand or a few strands of the CIC conductors. The localized normal zone causes current and heat transfer between a disturbed strand and neighboring strands. Electrical and thermal contact characteristics between strands thus have an effect on the transient stability of the CIC conductors. In this paper the effect of contact characteristics between strands on the CIC conductor stability is presented based on the measured heat transfer characteristics of supercritical helium (SHe) for the local heating. The quench and recovery processes of the strands for the abrupt and highly localized disturbance are analyzed at the boundary between quench and recovery.

  • PDF

수평격판을 갖는 정사각형 밀폐공간내에서 자연대류 유동 및 열전달 (Natural Convective Flow and Heat Transfer in a Square Enclosure with a Horizontal Partition)

  • 정인기;김점수;송동주
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2304-2314
    • /
    • 1993
  • Natural convective flow and heat transfer in a two-dimensional square enclosure fitted with a horizontal partition are investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was situated perpendicularly at the one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were carried out with the variations of length, position and thermal conductivity of the partition, and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). As the results, an oscillatory motion of natural convection is resulted in a sudden rise of overall heat transfer, but the increase of length of partition is significantly restrained the increase of Nusselt number. The maximum heat transfer was shown just before the transition of the direction of oscillating flow. An oscillatory motion of flow was perfectly shown the stability with the decrease of the length of partition and Rayleigh number. Also, the heat transfer was raised with the increase of the thermal conductivity in proportion to the increase of the length of partition. The stability and oscillation of flow are affected by the position of partition.

하중전이를 고려한 앵커보강사면의 안정해석 (Stability Analysis of Anchored Slope Considering Load Transfer)

  • 김낙경;윤승권;김성규;주용선;박종식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.1113-1124
    • /
    • 2009
  • The limit equilibrium method and finite element method have been commonly used to assess the stability of anchored slope. However, the existing limit equilibrium methods do not consider the load transfer of anchor and, if the potential failure surface crosses the bonded zone of anchors, the anchor loads are not included in computing the factor of safety. In this paper, simplified bishop method, one among several methods based on the limit equilibrium is used to develope the Excel Sheet program and the working load of anchor along the failure surface is calculated by Flamant's formula, proposed by Morlier and Tenier(1982). Additionally, the finite element analysis of anchored slope considering the load transfer is performed in order to compare with the result from the limit equilibrium analysis and analyze the reinforced effect of anchor. From this study, new modelling method that limits the reinforcing range and considers the load transfer is proposed and Excel Sheet program is developed. The factor of safety for several cases between PC STABL and Excel Sheet program is also compared for verification of the program.

  • PDF

TRIGA Mark-II 원자로의 동특성 해석 (Dynamic analysis of TRIGA Mark-II reactor)

  • 이양수
    • 전기의세계
    • /
    • 제14권6호
    • /
    • pp.8-13
    • /
    • 1965
  • The TRIGA Mark-II Reactor is very simple to analyze the dynamic characteristics, so that the heat transfer function of the reactor fuel rod is able to be considered as a over-all feedback transfer function. The heat transfer dynamics of the fuel rod is derived under some assumptions. And the over-all reactor transfer function is analytically calcu- lated and it is compared with the measured value. The reactor dynamics and the stability are analyzed by means of the Root-Locus and the Nyquist.

  • PDF

열적용량과 전압안정도를 고려한 ATC 계산 방법에 관한 연구 (The ATC Calculation Method with Thermal Constraints and Voltage Stability Constraints)

  • 김재현
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.86-93
    • /
    • 2007
  • 본 논문은 가용송전용량(ATC)를 계산하기 위한 두 가지 빠른 계산 기법을 제안한다. 이 방법들은 선로의 열적용량한계(Thermal ATC)와 전압 안정도한계(Voltage ATC)를 제약조건으로 ATC를 계산한다. 먼저 선로의 열적용량을 고려한 방법에서는 모선의 전력 변화에 대한 선로의 조류 감도인 PTDF와 n-1 상정사고를 고려한 LODF를 이용하였으며, 전압안정도를 고려한 방법에서는 2모선 등가 시스템을 이용하여 최대 전력을 구하는 방법을 이용하였다. 제안된 방법은 IEEE 30모선 계통에 적용하였으며 그 결과를 다른 방법과 비교하여 제안된 방법의 타당성을 입증하였다.