• Title/Summary/Keyword: Transformer

Search Result 4,281, Processing Time 0.03 seconds

Conceptual Design of a Single Phase 33 MVA HTS Transformer with a Tertiary Winding (3차 권선을 고려한 단상 33MVA 고온초전도 변압기의 개념설계)

  • Lee, S.W.;Kim, W.S.;Hahn, S.Y.;Hwang, Y.I.;Choi, K.D.
    • Progress in Superconductivity
    • /
    • v.7 no.2
    • /
    • pp.162-166
    • /
    • 2006
  • We have proposed a 3 phase, 100 MVA, 154 kV class HTS transformer substituting for a 60 MVA conventional transformer. The power transformer of 154 kV class has a tertiary winding besides primary and secondary windings. So the HTS transformer should have the 3rd superconducting winding. In this paper, we designed conceptually the structure of the superconducting windings of a single phase 33 MVA transformer. The electrical characteristics of the HTS transformer such as % impedance and AC loss vary with the arrangement of the windings and gaps between windings. We analyzed the effects of the winding parameters, evaluated the cost of each design, and proposed a suitable HTS transformer model for future power distribution system.

  • PDF

A Study on Mechanical Characteristic Analysis for Main Transformer of High Speed Railway (고속철도차량 주변압기 기계적 특성 분석)

  • Han, Young-Jae;Kim, Seog-Won;Lee, Tae-Hyoung;Koo, Hun-Mo;Cho, Kwong-Woo;Park, Sang-Ock
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.713-718
    • /
    • 2006
  • In this study, temperature sensors were adhered to transformer that is used in KHST(Korean High-Speed Train) to verify variation of temperature characteristics about transformer synthetically and efficiently. In the case that temperature of transformer exceeds reference temperature for running of KHST, overheating of transformer may cause a fatal accident of vehicle. Characteristics and main specifications of transformer in KHST were described in this paper. Also, measuring system for temperature measurement of transformer was explained in brief. Temperature data of transformer was acquired using measuring system, KRRI(Korea Railroad Research Institute) analyzed characteristic in contrast with comparing with temperature of transformer about month, running speed and running time.

  • PDF

Evaluation Technique for Linearity of Ratio Error of Instrument Transformer Comparator Using Voltage Transformer with Wide Range of Error Ratios (넓은 범위의 비오차를 갖는 전압변성기를 이용한 계기용 변성기 비교 측정 장치의 비오차 직선성 평가기술)

  • Jung Jae Kap;Kwon Sung Won;Kim Han Jun;Park Young Tae;Kim Myung Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.2
    • /
    • pp.66-70
    • /
    • 2005
  • Linearity of ratio error of instrument transformer comparator has been tested using wide ratio error voltage transformer(VT) with the ratio errors in the range of -3 % to 3 %. The technique is the method for evaluation of the linearity for instrument transformer comparator by comparing both the theoretical and experimental values in wide ratio error VT. The developed method has been successfully applied for calibration and correction in instrument transformer comparator belonging to industry.

Integrated Magnetic Transformer for ZVS Phase Shift Full Bridge Converter

  • Li, Xin-Lan;Shin, Yong-Hwan;Won, Jae-Sun;Kim, Jong-Sun;Shin, Hwi-Beom
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.119-126
    • /
    • 2010
  • An integrated magnetic (IM) transformer is proposed for a phase shifted full bridge (PSFB) converter with zero voltage switching (ZVS). In a proposed IM transformer, the transformer is located on the center leg of E-core and the output inductor is wound on two outer legs with air gap. The proposed IM transformer is analyzed by using the magnetic capacitor model. For reducing the core size, EE core is redesigned. The proposed IM transformer is experimentally verified on a 1.2 kW prototype converter. The converter efficiency with the proposed IM transformer is about 93 % at full load and its volume size can be reduced. It can be expected that the power density can be largely increased with the proposed IM transformer.

Single Phase NPC Module - Development of 75KVA Single Phase Smart Transformer with 3 Serial Cascade Configuration (단상 NPC Module- 3직렬 Cascade 구성 방식의 75KVA급 단상 지능형 변압기 개발)

  • Park, Ju-Young;Niyitegeka, Gedeon;Cho, Kyeong-Sig;Kim, Myung-Yong;Park, Ga-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.118-125
    • /
    • 2017
  • In this paper, we propose a smart transformer for a smart transformer miniature model, which can replace a 60 [Hz] single-phase transformer installed in an electric vehicle. The proposed smart transformer is lighter than a conventional transformer, can control instantaneous voltage, and can be expected to improve power quality through harmonic compensation. The proposed intelligent transformer consists of an incoming part, an AC/DC converter, and a dual active bridge. Only the incoming part and the AC/DC converter are described in this paper. The proposed intelligent transformer has 75 kVA 3.3 kV input and 750 V DC output, which are verified by simulation and experiment.

High-Speed Transformer for Panoptic Segmentation

  • Baek, Jong-Hyeon;Kim, Dae-Hyun;Lee, Hee-Kyung;Choo, Hyon-Gon;Koh, Yeong Jun
    • Journal of Broadcast Engineering
    • /
    • v.27 no.7
    • /
    • pp.1011-1020
    • /
    • 2022
  • Recent high-performance panoptic segmentation models are based on transformer architectures. However, transformer-based panoptic segmentation methods are basically slower than convolution-based methods, since the attention mechanism in the transformer requires quadratic complexity w.r.t. image resolution. Also, sine and cosine computation for positional embedding in the transformer also yields a bottleneck for computation time. To address these problems, we adopt three modules to speed up the inference runtime of the transformer-based panoptic segmentation. First, we perform channel-level reduction using depth-wise separable convolution for inputs of the transformer decoder. Second, we replace sine and cosine-based positional encoding with convolution operations, called conv-embedding. We also apply a separable self-attention to the transformer encoder to lower quadratic complexity to linear one for numbers of image pixels. As result, the proposed model achieves 44% faster frame per second than baseline on ADE20K panoptic validation dataset, when we use all three modules.

Analysis of the Contactless Power Transfer System Using Modeling and Analysis of the Contactless Transformer

  • Ryu Myung-Hyo;Kim Jong-Hyun;Baek Ju-Won;Cha Hon-Nyong
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.351-358
    • /
    • 2006
  • In this paper, the electrical characteristics of the contactless transformer is presented using the conventional coupled inductor theory. Compared with the conventional transformer, the contactless transformer has a large airgap, long primary wire and multi-secondary wire. As such, the contactless transformer has a large leakage inductance, small magnetizing inductance and poor coupling coefficient. Therefore, large magnetizing currents flow through the entire primary system due to small magnetizing inductance, resulting in low overall system efficiency. In high power applications, the contactless transformer is so bulky and heavy that it needs to be split by some light and small transformers. So, the contactless transformer needs several small transformer modules that are connected in series or parallel to transfer the primary power to the secondary one. This paper shows the analysis and measurement results of each contactless transformer module and comparison results between the series- and parallel-connection of the contactless transformer. The results are verified on the simulation based on the theoretical analysis and the 30kW experimental prototype.

Development and Characteristics of Detector for Open of Current Transformer Secondary Terminal (변류기 2차측 개방 보호장치 개발 및 특성)

  • Choi, Sang-Won;Song, Ki-Chan
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.20-25
    • /
    • 2007
  • Instrument transformers are a safe measurement device designed to measure high voltage and large current. A current transformer(CT) is a type of instrument transformer designed to provide a current in its secondary winding proportional to the current flowing in its primary. It is commonly used in metering and protective relaying in the electrical power industry where it facilitates the safe measurement of large current. But, care must be taken that the secondary of a current transformer is not disconnected from its load while current is flowing in the primary, as this will produce a dangerously high voltage across the open secondary, and may permanently affect the accuracy of the transformer. Especially, industrial disaster such as an electric shock and/or a burn accident occurs occasionally by disregard of warning or attention. In this paper, we developed the detector for open of current transformer secondary terminal, and which was tested by the Korea Electrotechnology Research Institute. Test results show that Current Transformer secondary Open Detector(CTOD) interrupted within one second electronically when the 2nd terminal of current transformer opened.

Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer (몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

The Safety Survey Analysis and Consideration of Small Transformer (소형 변압기 안전성 실태 분석 및 고찰)

  • Kim, Sung-Sam
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, safety certification products and safety condition of small transformer is analyzed in industries field and educational facilities. In transformer of 50places, absolute majority is step down transformer to measure of instrument. Most transformers were below 5kVA and 1~3kVA capacity was the mainstream. In industries field, 5 transformers were found without safety certification according to the Electrical Appliances Safety Control Act as cheap product prefer and lack of safety consciousness. Mark & number, voltage, date of manufacture of safety certification must show item of certification. However date of manufacture showed in product of 18%, 9places. As result of thermal imaging camera, running temperature of transformer was showed in below of target temperature. However as a narrow space of transformer and wall, power cable was touched on a ventilating flue in transformer. It was simple carelessness case that surface fouling and temperature ageing of transformer accelerate. Power poor connection, neglect of transformer in production equipment, fall damage by setup incongruity and ground omission were found in case of illogicality item of transformer.