Conceptual Design of Single Phase 10MVA HTS Transformer (단상 10MVA 고온초전도 변압기 개념설계)

  • 석복렬;최명준
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.42-46
    • /
    • 2002
  • This research is conducted with the object of Piling up the foundation of design technologies for high temperature superconducting (HTS) power transformer which is thought to be as a powerful power transformer of next generation. In this study, not only the theoretical design of high temperature superconducting (HTS) transformer but also the arrangements of superconducting tape and the cooling method have been conducted. Moreover, electromagnetic analyses using finite element method (FEM) were conducted to confirm the efficiency of the designed transformer.

A Transformer Design and Magnetic Analysis Model for the High-Speed EMU (동력분산형 고속철도용 변압기 설계 및 자계해석 모델)

  • Park, Byoung-Gun;Hyun, Dong-Seok
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.517-524
    • /
    • 2009
  • This paper proposes a magnetic analysis model and design method of transformer for the high-speed EMU. It has a many part of the consideration in design because the transformer in high-speed train has the multiple output. Also the output characteristic, weight, and size of transformer is an important factor. This research proposes a design method of transformer in high-speed EMU. And it is easy to design by using the analysis model in design the transformer through the establishment of the magnetic analysis model.

  • PDF

Scott Transformer Modeling using Simulink on the AC Substation (Simulink를 이용한 교류 급전변전소의 스코트변압기 모델링)

  • Kim, Tae-Geun;Park, Young;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2317-2322
    • /
    • 2011
  • In three-phase power, when the power is supplied to the single phase load, there is the unbalance of load in the three-phase power. So the scott transformer is used in the power system to supply a single phase load in three-phase power without the unbalance of loads. Especially, the scott transformer is used in the AC substation of electric railroad. Two single phase transformers are combined by T-wiring in the scott transformer. So, two single phase voltage is provided by differing $90^{\circ}$ phase in three-phase power. The selection of related equipment and correction of protective relay are not easy from characteristic of the scott transformer when shunt and ground faults occur. In this paper, electric model of the scott transformer is suggested and the current of the scott transformer in shunt and ground faults is analyzed. Also, the scott transformer model is demonstrated by using Sinulink.

  • PDF

Problem Analysis by Iron Core Structure of the Transformer on Asymmetric three Phase lines and Prevention Measures (비대칭 3상 선로에서 변압기의 철심구조별 문제점 분석 및 방지대책)

  • Shin, Dong-Yeol;Yun, Dong-Hyun;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1536-1541
    • /
    • 2012
  • The study analyzed problems by iron core structure of the three phased transformer on asymmetric three phase lines, which included line disconnections, ground faults, COS OFF, and unbalanced loads on the power distribution system. In particular, by analyzing PT combustion cases within the MOF, the study was able to analyze the combustion cause of the core-type transformer and its effect on the system, conduct simulations and practice demonstrations on the characteristics for each iron core structure of the three phase transformer using PSCAD/EMTDC, and suggest measures to prevent the combustion of the core-type transformer.

A Study on Characteristics of Step-down Piezoelectric Transformer Using Contour Extended Vibration Mode (경방향 확장 진동모드를 이용한 강압용 압전변압기의 특성에 관한 연구)

  • Lee, Won-Jae;Min, Bok-Ki;Song, Jae-Sung;Chong, Hyon-Ho;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.638-641
    • /
    • 2002
  • This paper presents design and construct of flat type step-down piezoelectric transformer for the application to AC-adapters. This piezoelectric transformer operated in resonance vibration mode. In this paper, Finite element method(FEM) was used for analysis piezoelectric transformers. Vibration mode and electric field of piezoelectric transformer at resonance frequency were simulated. Using this simulation, we manufactured flat type piezoelecric transformer and measured its output characteristics. As results, output power was linearly increased by increasing input power at resonance frequency. And it was found that the transformer exhibited an output power of 11.4[W] at 60[V] input voltage. From these results, we expect that this piezoelecric transformer can be applied to AC adapters.

  • PDF

Scott Transformer Modeling using PSIM on the AC Substation in the Elect ric Railroad (전기철도의 교류 급전변전소에서 PSIM을 이용한 스코트변압기 모델링)

  • Kim, Sung-Dae;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1892-1897
    • /
    • 2010
  • In three-phase power, when the power is supplied to the single phase load, there is the unbalance of load in the three-phase power. So the scott transformer is used in the power system to supply a single phase load in three-phase power without the unbalance of loads. Especially, the scott transformer is used in the AC substation of electric railroad. Two single phase transformers are combined by T-wiring in the scott transformer. So, two single phase voltage is provided by differing $90^{\circ}$ phase in three-phase power. The selection of related equipment and correction of protective relay are not easy from characteristic of the scott transformer when shunt and ground faults occur. PSIM(Power Electronics Simulator) is optimal simulation software in field of the power electronics and provide the simple and convenient user interface. In this paper, electric model of the scott transformer is suggested and the current of the scott transformer in shunt and ground faults is analyzed. Also, the scott transformer model is demonstrated by using PSIM.

  • PDF

Ageing Diagnostics in Oil Transformer for Large Capacity due to Test methods (시험방법에 의한 대용량 유입변압기의 열화진단)

  • Sim, Yoon-Tae;Kim, Wang-Gon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.96-99
    • /
    • 2003
  • In this paper, ageing diagnostics in the large capacity oil transformer are investigated. Following items are investigated for the ageing diagnostic in transformer oils (leakage current of sensor, power consumption and temperature of transformer oil). All temperature data are gathered from daily report in the substation. The power consumption of transformer are gathered output report of APIS(Airport Power Information System). Especially, data of sensor leakage current are accumulated from the online diagnostic system for transformer oil. The temperature of transformer oils major change factor was ambient temperature and capacity of power load. The leakage current are change by oil temperature. The leakage current ware not more than 2 [nA] in summer,

  • PDF

Detection of the Ultrasonic Signals due to Partial Discharges in a 154kV Transformer

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.297-303
    • /
    • 2002
  • We have developed an on-line ultrasonic detector to monitor partial discharge in an operating transformer. The ultrasonic sensor has 150[KHz] resonance frequency and contains a pre-amplifier with 60[㏈] gain. The on-line ultrasonic detector has 50~300[KHz] frequency band-pass filter to remove electrical and mechanical noises from the transformer. This detector has an ultrasonic signal discrimination algorithm which discriminates ultrasonic signals due to partial discharge in a transformer. A moving average method of ultrasonic signal number was employed to effectively monitor the increasing trend of the partial discharge. This paper describes an experience of partial discharge detection in a 154[㎸] operating transformer using an ultrasonic detector. With regards to gas analysis in oil, C2H2 gas was produced with a warning level in this transformer We detected ultrasonic signals on the transformer steel wall, and estimated the position of partial discharge. With further inspection, we found carbonized marks due to partial discharge on the supporting bolt which fastens the windings.

Analysis of Vibration-Frequency Spectrum of Distribution Transformer for Noise Reduction (배전용변압기의 소응저감을 위한 진동주파수의 스펙트럼분석)

  • Lee, Do-Hoon;Kim, Jae-Chul;Song, Seung-Youp;Lee, Hyun-Gu;Kim, Kwang-Whoa
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.346-348
    • /
    • 2002
  • This paper analyze spectrum of vibration-frequencies to reduce noise level of distribution transformer. Using loading back method on same condition of a real load to grasp the effect of core and winding which are caused by the transformer vibration. we were measured the vibration-frequency by varing applied voltage and load current of a transformer. The major cause of a transformer vibration is occured by the harmonic effects, and was identified that the vibration is less influenced by the coil. As the result of this paper, comparing the transformer with some isolated material with the general transformer the transformer with some isolated material could reduce spectral amplitude of vibration-frequencies.

  • PDF

A Study on the Safty Diagnosis and Evaluation of Oil-immersed Transformer using fuzzy Algorithm (퍼지 알고리즘을 이용한 유중 변압기의 안전진단 및 평가에 관한 연구)

  • Kim, Young-Il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.190-195
    • /
    • 2006
  • In this paper, safety algorithm of transformer is introduced for the sake of MV/LV distribution customers by using fuzzy theory. The current-carrying capacity of transformer is usually determined by the maximum temperature at which the transformer is permitted to operate. Overload of transformer has an effect on transformer utilization rate and maximum temperature rises as well as maximum ambient temperature of insulating materials. Therefore, we proposed the safety algorithm considering the overload of transformer and ambient temperature in this paper. We introduced the correlational equations between each parameters using experimental data of IEEE std C57.91-1995, and deduced the result using fuzzy reasoning. We guessed the safety algorithm making a diagnosis for the safety status of oil-immersed transformer.