• Title/Summary/Keyword: Transient analysis

Search Result 3,032, Processing Time 0.04 seconds

Transient Response Characteristics of Vehicle Seatbelt (자동차 시트벨트의 과도응답 특성에 관한 연구)

  • Kim, Chang-Hee;Lee, Seok-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.9
    • /
    • pp.71-77
    • /
    • 2020
  • In recent years, as a consequence of the technological advancements in the automobile industry and changes in consumer demands, the reduction of noise inside vehicles rather than vehicle performance has increasingly become an important factor of interest. To date, most studies have focused on noise and vibration reduction techniques for the engine and drive system of vehicles. In this research, a comparative analysis for reducing the effect of vehicle seatbelts on the transient response is performed using the test of vehicle conditions and transient response analysis in accordance with seatbelt conditions. After the sensitivity analysis, the specifications for improvement were designed based on the transient response analysis. It was confirmed that the transient response characteristics were improved by the transient response analysis and vehicle conditions test. Through computer-aided engineering, the transient response characteristics of seatbelts were checked with less cost and time.

Transient Stability Analysis of Power System by Transient Energy Method (과도에너지법에 의한 전력계통의 과도안정도 해석에 관한 연구)

  • 김준현;설용태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.2
    • /
    • pp.59-64
    • /
    • 1983
  • This paper deals with the transient energy method of transient stability analysis of multi-machine power system by improving the transfer conductance, the kinetic energy and the critical transient energy. The tranfer conductance is considered more correctly, the generators of system are seperated to two states (critical and the rest state)and the correction term of critical transient energy (to reference point) is added. This analysis is performed by digital computer simulation and the application of this method to two model systems has shown its superiority to other available methods.

  • PDF

3-Dimensional Numerical Analysis for Thermal Stratification in Surgeline in Nuclear Power Plant (원전 밀림관 열성층의 3 차원 수치해석)

  • Kim, Young-Jong;Kim, Maan-Won;Ko, Eun-Mi
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.729-734
    • /
    • 2008
  • A thermal stratification may occur in the horizontal parts of the surge line during operating transients of the pressurizer, which produces relatively high fatigue usage factor. Heat-up transient is the most severe case among the transient conditions. In this study, to study the relationship between the magnitude of thermal stratification and the length of vertical part of the surge line, some parametric fluid-structure interaction (FSI) analyses with different length variables of the vertical part of the surge line were performed for plant heat-up transient condition by using 3-dimensional numerical analysis. The conservativeness of the traditional finite element model for thermal stratification analysis based on the conservative assumption in the surge line was also discussed by comparison of the results of 3-dimensional transient FSI analysis of this study. Stresses calculated with 3-dimensional transient model were considerably reduced comparing with the traditional analysis.

  • PDF

The Development of Transient Analysis Model and Performace Analysis of 345[kV] 100[MVA] STATCOM (345[kV] 100[MVA] STATCOM 과도해석 모델 개발 및 동특성 분석)

  • Yoon, Jong-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.28-34
    • /
    • 2011
  • This paper describes the development of the transient analysis model of 345[kV] 100[MVA] STATCOM and the result of the performance analysis. The Korea power utility company, KEPCO began a commercial operation of a 100[MVA] STATCOM(Static synchronous COMpensator) at 345[kV] Migeum substation in Seoul. In order to operate a new control device like STATCOM to the power system, suitable transient model is needed. Therfore, Korea Electric Power Coporation(KEPCO) developed a transient analysis models using EMTDC/PSCAD. The development of this transient analysis model is based on the actual STATCOM S/W algorithm and H/W specification that was provided by its manufacture. Through this model, the transient/dynamic performance of STATCOM at Migeum substation can be analyzed.

Transient Characteristics of Separately Excited d-c Motor Driven by Thyristor d-c Chopper (Thyristor 직류 Chopper방식으로 구동되는 직류타여자식 전동기의 과도특성해석법)

  • Hee Young Chun
    • 전기의세계
    • /
    • v.21 no.2
    • /
    • pp.9-19
    • /
    • 1972
  • The transient characteristics of separately excited d-c motor driven by thyristor d-c chopper is studied in this paper. The armature controlled system is applied. As a result of theoretrical analysis the following conculsions were drawn: (1) For the transient analysis, it is recognized that the state transition analysis is a more general method and powerful tool than the state equation method or signal flow graph method, although it includes iterative matrix calculations. And the system is dealt with a finite width sampled-data system in the state transition analysis. (2) The transient characteristics of the motor angular velocity and its torque to the sampling duration variation are compared with those due to the amplitude variation of d-c chopper voltage as follows. The attenuation rate of the transient characteristics is equal in both cases, but the initial value of the transient characteristics in former case is greater than in latter case. (3) The roots of characteristics equation of the system lie inside the unit circle of the Z-plane. Therefor the system is stable. Further it is found that as the sampling duration is decreased the relative stability is lessened.

  • PDF

Analysis on transient stability for drilling rigs power system (석유 시추선 전력 계통의 과도 안정도 해석)

  • Kim, Yoon-Sik;Kim, Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1119-1124
    • /
    • 2014
  • This paper describes the emergency situation which occurs in Drilling Rig power system. Especially, we focused on power system transient characteristics on propulsion motor load and generator elimination situation in Drilling Rig operation. We performed numerical simulation and analyzed the result for power system transient stability characteristics on each condition for excitation system and governor control system using ETAP (Electrical Transient Analysis Program).

Transient Vibration Analysis of an Agricultural Tractor (농업용 트랙터의 과도 진동 분석)

  • 김용준;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.26 no.6
    • /
    • pp.509-516
    • /
    • 2001
  • This paper introduced some advantages of the time-frequency analysis of vibration and investigated, using the time-frequency transform, the characteristics of the transient motion of a tractor seat, which occurred during the tractor traversed over a rectangular obstacle on the flat surface. The characteristics of the short-time courier and wavelet transforms as time-frequency analysis methods were introduced and discussed to figure out which is more suitable to the analysis of the transient motions of agricultural tractors. Using each transform, transient vibration of a tractor seat was analyzed. Results of the analysis showed that the transient vibration of the seat was influenced by the natural frequencies of vertical mode of chassis, pitching mode of engine and pitching mode of cab of the tractor. The time sequence of the natural mode of tractor vibration was also revealed by the time-frequency analysis. The vibration path analysis by the time-frequency transform showed that the vibration energies transmitted from the front mounts to the seat were less than those from the rear mounts. The energy reduction ratios between the cab mounts and seat were also estimated to be about 72∼78%. The front mounts showed larger reduction than the rear mounts. However, the reduction difference between the right and left sides mounts was negligibly small. The short time Fourier transform was found to be a proper method for investigating the transient motions of farm machines and their effects on the ride vibration.

  • PDF

TRANSIENT PERFORMANCE OF AN SI ENGINE BY TRANSIENT RESPONSE SPECIFICATIONS

  • Kwark, J.H.;Jeon, C.H.;Chang, Y.J.
    • International Journal of Automotive Technology
    • /
    • v.4 no.3
    • /
    • pp.109-117
    • /
    • 2003
  • The analysis and evaluation of the transient performance by the transient response specifications under various acceleration speeds and types based on driver's typical acceleration habit are implemented by the experimental study to provide the appropriate direction for the transient control in a gasoline engine. The concept of the transient response specifications which consist of delay time, rising time, maximum overshoot and settling time, and the analysis method using them are introduced to evaluate the characteristics of the transient performance quantitatively. Furthermore four acceleration speeds and four acceleration types are set respectively to realize the various transient states which are similar to the real drive. Several performance parameters in terms of engine speed, manifold absolute pressure, fuel injection duration and air excess ratio are measured simultaneously during the various acceleration using a throttle actuator controlled by a PC. The transient response specifications characterized well the transient performance for the various acceleration speed and types quantitatively. Delay and rising time with increment of the acceleration speed became shorter, but settling time did longer. Intensified acceleration type appeared to be the most economical in view of fuel consumption, and linear acceleration type was found to have the least harmful emission concentration.

Transient Analysis of Pipeline System Considering Unsteady Friction Models (다양한 부정류 마찰항을 고려한 관망 천이류 모의와 실험연구)

  • Jang, Il;Kim, Sang Hyun;Kim, Ji Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.657-664
    • /
    • 2008
  • This research compared several unsteady friction models for transient analysis of pipeline system. Unsteady friction is an important factor for accurate simulation of hydraulic transient. Steady friction, quasi-steady friction, Zielke's model and two versions of Brunone model were compared with measurement data of identical pipeline conditions. This study showed that the existing simple steady friction model can be useful for the safer design of pipeline system due to its overestimation of waterhammer, but introduction of more elaborate models are required for advanced analysis such as inverse transient analysis of friction or leakage and the preliminary analysis of water quality prediction of water distribution system.

Simulated Analysis for the Transient Impedance Behaviors of Counterpoises Subjected to the Impulsive Currents (임펄스전류에 의한 매설지선의 과도임피던스특성에 대한 모의해석)

  • Joe, Jeong-Hyeon;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1861-1868
    • /
    • 2009
  • A ground electrode subjected to lightning surge current shows the transient impedance behaviors. The ground electrode for protection against lightning should be evaluated in view of the transient grounding impedance and conventional grounding impedance, not ground resistance. The transient impedance characteristics of ground electrodes are influenced by the shape of ground electrode and the soil characteristics, as well as the waveform of lightning surge current. In order to propose a simulation method of analyzing the transient impedance characteristics of the grounding system in practical use, this paper suggests a theoretical analysis method of distributed parameter circuit model to simulate the transient impedance characteristics of counterpoise subjected to lightning surge current. EMTP and Matlab programs were employed to compute the transient grounding impedances of three counterpoises with different lengths. As a consequence, the simulated results using the proposed distributed parameter circuit model are in good agreement with the measured results.