• 제목/요약/키워드: Transmission power setting

검색결과 75건 처리시간 0.027초

오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰 (Examination with Transmission Line Distance Relay Setting Rule Considering Error)

  • 조성진;최면송;현승호;김종욱;이주왕;조범섭;유영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

송전계통 보호계전기 보호협조 평가 시스템 (A Software System for Evaluation Setting and Coordination of Protective Relays in Power Transmission System)

  • 최면송;이승재;민병운;조필성
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권10호
    • /
    • pp.518-524
    • /
    • 2002
  • A software system that has functions of setting and coordination checking of protective relays in power transmission system has been developed. The developed system utilizes database system to store the setting values of protective relays, power system parameters, checks the relay operation and evaluates coordination of relays in real Power system or test system. The fault data to simulates a fault to evaluate the coordination of relays is generated by PSS/E and EMTP. A universal logic generator module is added to adopt the variation of each relay's trip logic. The proposed system has been verified through many tests in the case study, and proved to be very powerful in inspecting the setting values and coordination of relays.

송전계통 보호계전기 정정값 검증을 위한 고장 시뮬레이터 개발 (A Fault Simulator for Power Transmission System Protective Relay Setting Evalutation)

  • 김기화;최면송;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.712-718
    • /
    • 1999
  • When a fault occurs in power transmission systems, protective relays play a roles of protecting the power system according to there setting values. Therefor, it is important that protective relays have high selectivity and sensitivity by correct setting the involves a large volume of data and is a complicated and very tedious, therefore vulnerable to the human errors. Also, it is very difficult to verify that the relays have correct operating parameters before the fault occurs. This paper porposed a method to testify the reliability of realys by showing the operation response to faults in the simulation of the real power system operation environment.

  • PDF

송전선로 지락사고 보호협조 프로그램 개발 (Program of Development on Protection Coordination for Impedance Fault in Power Transmission System)

  • 김홍석;이승재;최면성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1133-1135
    • /
    • 1999
  • In this paper we propose to develop program witch can improve the detecting capability of impedance fault in power transmission system. It is difficult to setting relay because the different type relays have many setting values to coordinate with each other. The proposed program assist a user in setting relay with convenience grapic environment and database.

  • PDF

Setting Considerations of Distance Relay for Transmission Line with STATCOM

  • Zhang, Wen-Hao;Lee, Seung-Jae;Choi, Myeon-Song
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.522-529
    • /
    • 2010
  • Distance relay plays an important role in the protection of transmission lines. The application of flexible AC transmission systems (FACTS) devices, such as the static synchronous compensator (STATCOM), could affect the performance of the distance relay because of compensation effect. This paper analyzes the application of distance relay on the protection of a transmission line containing STATCOM. New setting principles for different protection zones are proposed based on this analysis. A typical 500 kV transmission system employing STATCOM is modeled using Matlab/Simulink. The impact of STATCOM on distance protection scheme is studied for different fault types, fault locations, and system configurations. Based on simulation results, the performance of distance relay is evaluated. The setting principle can be verified for the transmission line with STATCOM.

Application of Adaptive Neuro-Fuzzy Inference System for Interference Management in Heterogeneous Network

  • Palanisamy, Padmaloshani;Sivaraj, Nirmala
    • ETRI Journal
    • /
    • 제40권3호
    • /
    • pp.318-329
    • /
    • 2018
  • Femtocell (FC) technology envisaged as a cost-effective approach to attain better indoor coverage of mobile voice and data service. Deployment of FCs over macrocell forms a heterogeneous network. In urban areas, the key factor limits the successful deployment of FCs is inter-cell interference (ICI), which severely affects the performance of victim users. Autonomous FC transmission power setting is one straightforward way for coordinating ICI in the downlink. Application of intelligent control using soft computing techniques has not yet explored well for wireless networks. In this work, autonomous FC transmission power setting strategy using Adaptive Neuro Fuzzy Inference System is proposed. The main advantage of the proposed method is zero signaling overhead, reduced computational complexity and bare minimum delay in performing power setting of FC base station because only the periodic channel measurement reports fed back by the user equipment are needed. System level simulation results validate the effectiveness of the proposed method by providing much better throughput, even under high interference activation scenario and cell edge users can be prevented from going outage.

765kV 송전계통 보호계전기의 오차분석을 통한 정정지침에 관한 연구 (A Study on the Protective Relay Setting Rules for 765kV Power System by Analysis of Errors)

  • 최면송;이승재;강상희;조성진;배영준;조범섭;유영식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권1호
    • /
    • pp.50-57
    • /
    • 2003
  • In this paper, the protective relay setting rules of Korean electric power system are studied by analysis of errors to be considered. An accurate operation of protective relays with accurate settings are important in power system reliability. The setting rules are used from the first establishment in 1982 and revision in 1990 Therefore, it needs revise and analysis of the setting rules because of environmental changes such as voltage raise or applied new technology of power system. Two major setting rules are studied. One is the rule for Zones of distance relay for transmission lines. The other is the one of differential current in a differential relay for power transformers. The range of errors in the setting rules accepted in the field experience is studied in simulation of case study. Also some guide lines for the range of errors in the setting rules are presented from the case study using Matlab simulation.

FACTS기기의 유효전력 제어특성을 고려한 모선간 송전용량 평가 알고리즘 (An Algorithm for BITC Evaluation considering the Power Control Characteristics of FACTS Devices)

  • 윤용범;추진부
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권2호
    • /
    • pp.113-118
    • /
    • 1999
  • In this, sensitivity based approach to estimate BITC(bilateral interchange transfer capacity) considering the real power flow control function of FACTS devices is presented. The real power flow setting of the FACTS devices is adjusted so that it transfers the power flow from the first violation point of transmission capacity to other transmission lines in the power system, thus allowing more power to be transferred from the specified generator bus to the specified load bus. The transfer between the two bus locations is increased from this new operating condition until a violation of transmission capacity limits occurs or until the setting of the FACTS devices can no longer be adjusted. The proposed algorithm is illustrated using examples of small and real life power system.

  • PDF

FACTS적용계통에서의 송전용량 평가 알고리즘 (An Algorithm for Transfer Capability Evaluation in Power Systems with FACTS Device)

  • 윤용범;윤종수;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.880-883
    • /
    • 1998
  • In this paper, sensitivity based approach to estimate BITC(bilateral interchange transfer capacity) considering the real power flow control function of FACTS device is presented. The real power flow setting of the FACTS device is adjusted so that it transfer the power flow from the first violation point of transmission capacity to other transmission lines in the power system, thus allowing more power to be transferred from the specified generator bus to the specified load bus. The transfer between the two bus locations is increased from this new operating condition until a violation of transmission capacity limits occurs or until the setting of the FACTS device can no longer be adjusted. The proposed algorithm is illustrated using examples of small and real life power system.

  • PDF

UML(Unified Modeling Language)기법을 이용한 PCM전류차동계전기 정정모듈 개발 (Development of PCM Current Differential Relay Setting Module Using UML)

  • 오태욱;오성민;민병운;이승재;최면송
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.329-331
    • /
    • 2003
  • PROSET2000 that is integrated protective management system had developed and used in order to automate the setting process of protective relays in transmission system protection. PROSET2000 have database for relay setting and automated for relay setting program within. This paper proposed PCM current differential relay setting program point of Object Oriented Programming paradigm using Unified Modeling Language about additional relay in PROSET2000. Nevertheless each relay uses same current differential but setting method is different. This paper discribed different thing about setting method of each relay and evaluated more effective and corrective relay setting program using UML.

  • PDF