• Title/Summary/Keyword: Transmission waveform

Search Result 114, Processing Time 0.025 seconds

Transmission waveform design for compressive sensing active sonar using the matrix projection from Gram matrix to identity matrix and a constraint for bandwidth (대역폭 제한 조건과 Gram 행렬의 단위행렬로의 사영을 이용한 압축센싱 능동소나 송신파형 설계)

  • Lee, Sehyun;Lee, Keunhwa;Lim, Jun-Seok;Cheong, Myoung-Jun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.5
    • /
    • pp.522-533
    • /
    • 2019
  • The compressive sensing model for range-Doppler estimation can be expressed as an under-determined linear system y = Ax. To find the solution of the linear system with the compressive sensing method, matrix A should be sufficiently incoherent and x to be sparse. In this paper, we propose a transmission waveform design method that maintains the bandwidth required by the sonar system while lowering the mutual coherence of the matrix A so that the matrix A is incoherent. The proposed method combines two methods of optimizing the sensing matrix with the alternating projection and suppressing unwanted frequency bands using the DFT (Discrete Fourier Transform) matrix. We compare range-Doppler estimation performance of existing waveform LFM(Linear Frequency Modulated) and designed waveform using the matched filter and the compressive sensing method. Simulation shows that the designed transmission waveform has better detection performance than the existing waveform LFM.

Development of Monitoring System for Biotelemetry Diagnosis of Multichannel ECG Data (다중채널 심전도 데이터의 원격진단을 위한 모니터링 시스템의 개발)

  • Jang, Won-Yeong;Jang, Won-Seok;Hong, Seung-Hong
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.113-120
    • /
    • 1991
  • This paper describes the implementation of a 3 channel ECG monitoring system. This system consists of an IBM-PC and simple accessory only. A PDTS (parallel data transmission system ) was designed to do monitor the data being operated with no effect and no exchange of software and hardware on the main transmission system in LOCAL mode. And it receives patient's ECG data from EPTS ( ECG processing and transmission system) of distant region. It provides on-line ECG waveform display, waveform storage, recall and editing the waveform. We have implemented the monitoring system by tw methods, and with system, we could directly monitor the EPTS and also receive the data from the remote ㅁe잉ion. This system was tested by experiments and examined its practical use.

  • PDF

Effect of Shifting the Pole-shoe and Damper-bar Centerlines on the No-load Voltage Waveform of a Tubular Hydro-generator

  • Fan, Zhen-nan;Han, Li;Liao, Yong;Xie, Li-dan;Wen, Kun;Wang, Jun;Dong, Xiu-cheng;Yao, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1294-1303
    • /
    • 2018
  • This study optimises the no-load voltage waveform of tubular hydro-generators by a simple design scheme. For different centerlines of the pole shoe and damper bar, the optimisation effects on the no-load voltage waveform are investigated in two tubular hydro-generators with different weighted powers (34 MW and 18 MW). The results are compared with those of the traditional stator-slots skewed design. The quality of the no-load voltage waveform was related to the shifting degree, and the different optimisation effects between the integer slot generator (q = 2) and the fractional slot generator (q = 11/2) were analysed. This research can improve the quality of the power output and no-load voltage waveform, and provide an effective reference for improving the industrial design and manufacture level of tubular hydro-generators.

Modeling of GMR Isolator for Data Transmission Utilizing Spin Valves (스핀밸브를 이용한 데이터 전송용 GMR 아이솔레이터의 모델링)

  • Park, S.;Kim, J.;Jo, S.
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.3
    • /
    • pp.109-113
    • /
    • 2004
  • GMR isolator was modeled using a Wheatstone bridge which is profitable for transmitting rectangular wave digital data, and the output voltage characteristics in relation to the input current were investigated in time domain. GMR isolator modeling was divided into two parts, namely magnetic and electric parts. The flow chart of the modeling was drawn in which measured MR curve of the spin valves were incorporated to obtain the electrical voltage output. For magnetic modeling, 3-dimensional model of planar coil was analyzed by FEM method to obtain the magnetic field strength corresponding to the input current. For electric modeling, resistance, inductance and capacitance of the planar coil were calculated and magnetic field waveform was obtained corresponding to the coil current waveform in time domain. Finally, MR-H curves of spin valves and the magnetic field waveform at the spin valves were composited to obtain the output voltage waveform of the isolator. Even though the amplitude of the coil current waveform was increased by 100%, decreased by 90%, or delayed by 10% of the period compared with the input current, similar transmitted output voltage waveform to the input current waveform was obtained due to hysteretic characteristics of the spin valves at the transmission speed of over 400 Mbit/s.

Analysis of Transmitter Leakage Effects in a FM-CW Radar (FM-CW 레이다에서의 송신 누설 전력 영향 분석)

  • Lee, Jong-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.50-51
    • /
    • 2011
  • In a radar system using a continuous waveform, the separated antennas are needed for transmission and reception to increase the sensitivity of the receiver channel. Even for these separated antennas, the serious intereference in the weak echo signal can occur due to the relatively strong power of the transmitted waveform. Therefore, in this paper, the effects of this leakage interference on the receiving signal are analyzed according to the degree of antenna isolation.

  • PDF

Design of FMCW radar waveform for flow measurement (유량 측정을 위한 FMCW 레이다 파형 설계)

  • Lee, Changki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.1
    • /
    • pp.83-90
    • /
    • 2020
  • A commercial flow measurement radar sensor estimates a quantity of flowed water using surface flow rate. In this way, the amount of water flowing per unit time cannot be measured accurately because of using an estimation result and it can't response environmental changes. For more accurate flow measurements we need width of waterway, water level and distance that water moved per unit time. Commonly two sensors are used to measure water level and flow rate. In this paper, we propose a method to simultaneously measure the water level and surface flow velocity using a single FMCW radar sensor and design the transmission waveform. In order to verify the waveform design, received signal is modelled based on transmission waveform. In addition, we consider phenomenons and problems that may occur in signal processing.

Real-Time Monitoring of ECG Signal under Ubiquitous Environment (유비쿼터스 환경 하의 실시간 심전도 신호 모니터링)

  • Kim, Jungjoon;Kim, Jin-Sub;Ryu, Chunha;Kim, Jeong-Hong;Park, Kil-Houm
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.9
    • /
    • pp.728-735
    • /
    • 2013
  • In this paper, we present a method of transmitting ECG signals in real-time mobile environment to be possible to implement the ubiquitous healthcare system. Because of the excessive amount of data transmission of ECG signals, it is necessary to propose a limitation to the real-time transmission. We propose a real-time electrocardiographic monitoring system based on the proposal of unusual waveform detection algorithm which detects the R-wave distortions from the arrhythmia ECG signals having unusual waveform of about 10% on average. It is very effective in terms of time and cost for medical staffs to monitor and analyze ECG signals for a long period of time. Monitoring unusual waveform by gradually adjusting the threshold values of potential and kurtosis makes the amount of data transmitted decrease and significance level of waveform to be enhanced. The unusual waveform detection algorithm is implemented with ubiquitous environment inter-working device client. It is applicable to ubiquitous healthcare system capable of real-time monitoring the ECG signal. While ensuring the mobility, it allows for real-time continuous monitoring of ECG signals.

On a study on PSOLA coding technique based on the measurement of formant similarity (포만트 유사도 측정에 의한 PSOLA 음성 부호화에 관한 연구)

  • 나덕수;이희원;김규홍;배명진
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.607-610
    • /
    • 1998
  • The major objectives of speech coding include high compression ratio for transmission in the band limited channel, high synthesized speech quality in terms of the intelligibility and the naturalness and fast processing speed. In general, speech coding methods are classified into the following three categories: the wavelform coding, the source coding and the hybird coding. In this paper, we proposed a new waveform coding method using PSOLA(pitch-synchronous overlap add) technique. First, we fixed one basic waveform per pitch and measured the formant similarity between basic and neighbor waveform. Second, if the similairy satisfied threshold values, we compress the neighbor waveform per pitch and then store or transmit. When the comparession is about 45%, we obtained about 4 in MOS.

  • PDF

Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement (반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템)

  • Jeon, Jeong Chay;Yoo, Jae-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

Implementation of an LFM-FSK Transceiver for Automotive Radar

  • Yoo, HyunGi;Park, MyoungYeol;Kim, YoungSu;Ahn, SangChul;Bien, Franklin
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.4
    • /
    • pp.258-264
    • /
    • 2015
  • The first 77 GHz transceiver that applies a heterodyne structure-based linear frequency modulation-frequency shift keying (LFM-FSK) front-end module (FEM) is presented. An LFM-FSK waveform generator is proposed for the transceiver design to avoid ghost target detection in a multi-target environment. This FEM consists of three parts: a frequency synthesizer, a 77 GHz up/down converter, and a baseband block. The purpose of the FEM is to make an appropriate beat frequency, which will be the key to solving problems in the digital signal processor (DSP). This paper mainly focuses on the most challenging tasks, including generating and conveying the correct transmission waveform in the 77 GHz frequency band to the DSP. A synthesizer test confirmed that the developed module for the signal generator of the LFM-FSK can produce an adequate transmission signal. Additionally, a loop back test confirmed that the output frequency of this module works well. This development will contribute to future progress in integrating a radar module for multi-target detection. By using the LFM-FSK waveform method, this radar transceiver is expected to provide multi-target detection, in contrast to the existing method.