• Title/Summary/Keyword: Treatment apparatus

Search Result 294, Processing Time 0.026 seconds

Optimum Depth and Volume Ratio of Aerobic to Anaerobic Bed for Development of Small-Scale Sewage Treatment Apparatus by Natural Purification Method (자연정화공법에 의한 소형 하수처리장치 개발을 위한 최적 깊이 및 호기.혐기 비율)

  • Seo, Dong-Cheol;Park, Mi-Ryoung;Kwak, Nae-Woon;Hwang, Ha-Na;Lee, Hong-Jae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.1
    • /
    • pp.14-24
    • /
    • 2006
  • To develop small-scale sewage treatment apparatus for detached house of agricultural village, a small-scale sewage treatment apparatus by natural purification method that consisted of aerobic and anaerobic bed was constructed. To reduce the area of a sewage treatment apparatus, four different fitter media were used and each filter medium was coarse sand, broken stone, steel slag, and mixed fitter media (coarse sand : broken stone : steel slag = 1:1:1). The efficiency of sewage treatment according to the depth of aerobic and anaerobic bed and the volume ratio of aerobic to anaerobic bed were investigated in small-scale sewage treatment apparatus. The removal rate of pollutants according to the depth of aerobic and anaerobic bed in small-scale sewage treatment apparatus was high in the order of 50 cm < 70 cm < 90 cm. The removal rate of pollutants according to the ratio of aerobic to anaerobic bed in small-scale sewage treatment apparatus was high in the order of 1:1 < 1:2 $\fallingdotseq$ 1:3. Under the optimum conditions, removal rate of BOD, COD, SS, T-N and T-P were $98{\sim}99,\;95{\sim}97,\;99,\;65{\sim}66\;and\;96{\sim}99%$ respectively, in small-scale sewage treatment apparatus.

Technical Considerations of Recycling Water Treatment/Supply Apparatus using Living Waste Water (생활 오배수를 이용한 중수처리 공급장치의 기술성 고찰)

  • Cho, Chung-Sik;Lee, Hee-Wan;Kim, Hong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.493-498
    • /
    • 2008
  • The several water resources are showed recently the various pollution types due to the industrialization and the disarranged district development. The living waste water, plant waste water and so are contaminated continuously and the recycling water is concerned highly to save the cost and to improve the environment as the general people. The dust and the heavy metal in the air and the acid rain are contaminating the river water and the underground water. The clean environment is on the rise to the general people and is to be the social problems. There is going to complement and repair the water supplying and fire extinguishing pipeline to save the construction cost and improve the environment in the construction facilities parts. Therefore, in this paper the recycling water treatment/supply apparatus using the living waste water is considerated technically and is raised on the practical uses.

  • PDF

Development of Sewage Treatment Apparatus for Detached House in Agricultural Village by Natural Purification Method (자연정화공법에 의한 농촌 전원 독립가구 하수처리장치 개발)

  • Seo, Dong-Cheol;Park, Mi-Ryoung;Kim, Hyung-Jun;Cho, In-Jae;Lee, Hong-Jae;Sung, Sun-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.202-210
    • /
    • 2006
  • To develop small-scale sewage treatment apparatus for detached house of agricultural village, a small-scale sewage treatment apparatus by natural purification method that consisted of packaged form of aerobic, anoxic and anaerobic bed was constructed. The efficiency of sewage treatment according to the sewage treatment method, sewage loading, and the injection method of sewage were investigated for small-scale sewage treatment apparatus of packaged form of aerobic, anoxic and anaerobic bed. The removal rate of pollutants according to the sewage treatment method for small-scale sewage treatment apparatus was high in the order of aerobic-anoxic-anoxic bed < aerobic-anoxic-anaerobic bed. The optimum filter media in small-scale sewage treatment apparatus was a broken stone. The removal rate of pollutants according to sewage loading in small-scale sewage treatment apparatus was high in the order of $1,200L/m^2{\cdot}day\fallingdotseq900L/m^2{\cdot}day\fallingdotseq600L/m^2{\cdot}day$. The removal rate of pollutants according to injection method of sewage in small-scale sewage treatment apparatus was high in the order of continuous injection $\fallingdotseq$ intermittent injection. When loaded under the optimum conditions, removal rate of BOD, COD, SS, T-N and T-P were 99, 95, 99, 83 and 96%, respectively, through this 3-stepped small-scale treatment apparatus arrayed with the order of aerobic, anoxic and anaerobic bed.

Analysis of Qigong Infrasound Treatment Apparatus (기공(氣功) 치료기(治療器)의 분석(分析) 연구(硏究))

  • Kim, Kyung-Cheol;Lee, Yong-Tae
    • Journal of The Association for Neo Medicine
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 1997
  • In order to basic study of the oriental medical engineering, the Qigong infrasound treatment apparatus is analyzed. The results is followed : 1. SY-201 type Qigong Infrasound Treatment Apparatus is composed of oscillator, amp, transducer. 2. The Qi production process is analyzed that EM wave changed sound wave of superlow frequency number and penetrated the human body deeply.

  • PDF

Treatment Performance and Microbial Community Structure in BAC-process Treating Contaminated Groundwater by Water-soluble Cutting Oil (생물활성탄을 이용한 절삭유로 오염된 지하수의 처리특성과 미생물군집구조 해석)

  • Lim Byung-Ran;Bae Ci Ae;Lim Ho-Ju;Cho Chang-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.71-76
    • /
    • 2006
  • Treatment performance and microbial community structure were investigated in water-soluble cutting oil treatment process using biological activated carbon. DOC removal in BACI column at $15^{\circ}C$ was higher than at $25^{\circ}C$, but those of BAC3 column after 60days was high at$25^{\circ}C$. Also, quinone content of first-step reactors at $25^{\circ}C$ and $15^{\circ}C$ was much the same, but those of the third-step reactor at $25^{\circ}C$ was higher than at $15^{\circ}C$. The dominant type of two apparatus was ubquinone (UQ)-l 0 followed by UQ-8. Menaquinones were detected from $25^{\circ}C$ apparatus and effluent. This suggested that DOC removal at $25^{\circ}C$ was advanced degradation by attached microorganisms on the activated carbon surface. The DOC removal in long-term activated carbon apparatus increased with going in BAC3 column. This indicated the influent of POC was a result of DOC removal efficiency decrease. Integrated DOC removal from start point in experiment to break point and quinone content were showed a tendency of increasing with going last-step activated carbon apparatus. Therefore, the biological activated carbon apparatus used by this study was effective treatment process in contaminated groundwater by water-soluble cutting oil.

Nutrient Removal in an Advanced Treatment Process using BIO-CLOD (BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거)

  • Park, Wan-Cheol;Lee, Mi-Ae;Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.4
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

The Characteristics on the Hair Growth Using Diathermic Adjustable High-Frequency Generator (심부투열용 가변형 고주파 발생기를 적용한 발모 촉진 특성)

  • Shim, Ji-Young;Hong, Ji-Tae;Kim, Ho-Sung;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1896-1897
    • /
    • 2007
  • Medical equipment of high frequency has been presently applied to various parts of human body and novel treatment effects have been shown by it. Recently there are many cases that high frequency apparatus has been used in dermatology as the interest in beauty has been growing. Especially used in skin, blood volume is increased by keeping surface temperature of skin at around $43^{\circ}C$ and domodex folliculorum are treated by applying high electric field. It is the aspect we consider that increasing blood volume and domodex folliculorum treatment take effect on hair loss. In this study, high frequency electrotherapy apparatus was proposed to be applied to hair loss treatment. For that, human body was experimented with varying output voltage and frequency. The adjustable switching signal for treatment was obtained from 100[kHz] to 1000[kHz] by using DSP. Stable output specific was also obtained by feedback control to protect human body. The best hair growth conditions were the output voltage of 1.2[kV], the frequency of near 300[kHz] and the maximum current of 2[mA]. We apply this high frequency electrotherapy apparatus to two bald men, 46-year-old and 45-year-old. After treatment for a month they had thick and strong hair.

  • PDF

Temperature Gradient Estimation of Floating Zone Furnace by Mean Lamellar Spacing Measurement in DS-processed TiAl Alloys

  • Jung, I.S.;Park, Jong-Moon;Wee, D.M.;Oh, Myung-Hoon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.28 no.2
    • /
    • pp.82-86
    • /
    • 2015
  • In this study, the temperature gradient of a floating zone (FZ) apparatus, which is very difficult to directly measure, could be estimated by using the relationships between the lamellar spacing of directionally solidified TiAl alloys and the solidification rate, It was found that the calculated temperature gradient of the FZ apparatus was much higher, and almost ten times higher than that of a Bridgman type directional solidification apparatus.

A Study on Recycle of Concreted Organic Waste water by Electroflotation Apparatus for Resource Recycle of Non-Metal (비금속 자원 재활용을 위한 전해부상 장치를 이용한 고농도 유기질 폐수의 재활용에 관한 연구)

  • Kim, Ki-Jun;Nam, Sang-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.653-658
    • /
    • 2012
  • There is an increasing interest in the use of electrochemical methods for the food waste treatment. The technologies using the electrochemical method provide ideal tools for approaching industrial and food wastes problems. Unlike other chemical treatments, the electrochemical systems do not make the volume of the secondary waste increase. The electrochemical methods can be operated with electrochemical apparatus and inorganic agent allow selective separation and recovery and even quieter than others. This study concerns design factors, electrode construction and wastewater treatment process of the electrochemical apparatus. The experiment of color, COD and BOD removal is much effective in using electrochemical method with ultrasonication and ozonation.

A Study on the Optimization of Ballast Water Treatment System for Scale-up (선박평형수 처리장치의 Scale-up을 위한 조건 최적화 연구)

  • Kang, Ahyoung;Song, Ju Yeong
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.630-635
    • /
    • 2016
  • In the prior work, we studied a ballast water treatment apparatus, which is secondary pollution free by using physical treatment of shear stress. The principle of this apparatus is smashing various microorganisms by shear stress generated between stationary outer cylinder and revolving inner cylinder. Because of various magnitude of shear stress according to the inner cylinder surface type and revolution speed, an appropriate surface type and optimum revolution speed should be studied by consecutive experiment to determine the reference data for commercial apparatus. Through a comparative study of disk type and cylinder type of ballast water treatment apparatus, cylinder type is turned out to be superb to disk type. In this study, we studied to determine the superior collaboration of cylinder type, groove type and knurling type of inner cylinder to non patterned outer cylinder, and to optimize the revolution speed and flow rate according to the gap between inner cylinder and outer cylinder. As a result, we could get perfect sterilization effect at groove type under the conditions of 250 mL/min of flow rate at 8,000 rpm and 500 mL/min of flow rate at 10,000 rpm respectively.