• Title/Summary/Keyword: Twisted insert

Search Result 6, Processing Time 0.015 seconds

An Experimental Study on Enhancement of Laminar Flow Heat Transfer in a Circular Pipe with Inserts (삽입물에 의한 관내 층류열전달 증진에 관한 실험적 연구)

  • 권영철;장근선;정지환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.667-673
    • /
    • 2000
  • In order to understand the laminar flow heat transfer enhancement by the swirl flow, the effects of heat transfer in a circular pipe with a twisted tape insert were investigated experimentally. In the present study, the uniform heat flux condition was considered. The laminar heat transfer correlations were developed using the least-square-fit from the surface temperature distribution of an electrically-heated pipe and flow property data. Average Nusselt number correlations with the twisted tape insert were expressed as a function of swirl parameter, Reynolds number and Prandtl number. In the case of the twisted ratio y = 6.05, the mean Nusselt number increased approximately 500% and the friction factor increased approximately 300%, compared to the case of the empty pipe, respectively.

  • PDF

A Study on the Performance of a Shell Tube Heat- Exchanger with Twisted Tape (비틀림 테이프에 의한 이중관형 열교환기의 성능에 관한 연구)

  • Kim, Doo-Chun;Kim, Chul-Han
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.2
    • /
    • pp.1-9
    • /
    • 1982
  • Friction losses and heat transfer characteristics were studied experimentally for fully developed tubulent flow in tubes with twisted tape swirl generators. Data were obtained for pitch- to-diameter ratios from 8.10 to 25.71 with water under forced convection cool ins conditions. The experimental results of this and that of previous swirl flow investigation by Smithberg and Landis were compared. Nusselt number and friction data are combined in a constant pumping power comparision for swirl and straight flow, which indicates that improvement of 2.0 times in the best performance can be obtained with twisted tape-insert tube. A twisted tape-insert tube is recommended in the case of low temperature difference in heat-exchanger.

  • PDF

Study on Laminar Heat Transfer Enhancement by Twisted-Inserts

  • Kwon, Young-Chel;Chang, Keun-Sun;Jeong, Ji-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.36-43
    • /
    • 2001
  • In order to understand the laminar heat transfer enhancement by swirl flow, the effects of heat transfer in a circular pipe with twisted inserts are investigated experimentally. In the present study, a uniform heat flux condition is considered. Laminar heat transfer correlations are developed using least square fit method from surface temperature distributions of an electrically-heated pipe and flow properties. Average Nusselt number correlations with twisted inserts are expressed as a function of swirl parameter, Reynolds number and prand시 number. When the twisted ratio is 6.50, mean Nusselt number and friction factor increase by approximately 500% and 300%, respectively, compared with the values for a pipe without inserts.

  • PDF

Effects of Number of Heating Walls on Heat Transfer in the Rough Square Channel with Twisted Tape (테이프가 있는 거친 사각채널에서 가열벽면의 수가 열전달에 미치는 효과)

  • Ahn, S.W.;Kim, M.H.;Bae, S.T.;Kang, H.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.17-22
    • /
    • 2006
  • Surface modifications like rib-roughening and displaced insert devices like the twisted tape are commonly used in applications such as compact heat exchangers and cooling systems. In this paper, regionally averaged heat transfer distributions in square channels with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. Each wall of the square channel is composed of isolated aluminum sections. Regionally averaged Nusselt number and channel averaged Nusselt number in turbulent air flows are presented for Reynold numbers from 8,900 to 29,000. We have obtained the following conclusions from the experimental study: 1) The local Nusselt number in the two-sided heated case is higher than that in the four-sided heated condition. 2) In the 4 heating wall channel with twisted tape inserts, Nusselt number based on bottom wall temperature is enhanced by 1.2 - 1.6 times if adding the axial interrupted ribs on the bottom wall only. 3) The twisted tape with interrupted ribs under the two-sided heating condition produces the highest heat transfer coefficient.

  • PDF

Effect of Twisted - Tape Tubulators on Heat Transfer and Flow Friction inside a Double Pipe Heat Exchanger

  • Phitakwinai, Sutida;Nilnont, Wanich;Thawichsri, Kosart
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.2
    • /
    • pp.124-131
    • /
    • 2015
  • Computational fluid dynamics (CFD) has been employed for the Heat exchanger efficiency of a counter flow heat exchanger. The Heat exchanger efficiency has been assessed by considering the computed Nusselt number and flow friction characteristics in the double pipes heat exchanger equipped with two types twisted-tapes: (1) single clockwise direction and (2) alternate clockwise and counterclockwise direction. Cold and hot water are used as working fluids in shell and tube side, respectively. Hot and cold water inlet mass flow rates ranging are between 0.04 and 0.25 kg/s, and 0.166 kg/s, respectively. The inlet hot and cold water temperatures are 54 and $30^{\circ}C$, respectively. The results obtained from the tube with twisted-tapes insert are compared with plain tube. Nusselt number and friction factor obtained by CFD simulations were compared with correlations available in the literature. The numerical results were found in good agreement with the results reported in literature.

A Study of the Material Properties of Steel Used to Repair the Stupa of State Preceptor Jigwang from Beopcheonsa Temple, Wonju in 1957 (1957년 원주 법천사지 지광국사탑 수리에 사용된 철물(鐵物)의 재료학적 특성 연구)

  • You, Harim;Lee, Jaesung;Lee, Taejong;Park, Heejeoung
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.4
    • /
    • pp.100-117
    • /
    • 2020
  • National Treasure no. 101, the stupa of State Preceptor Jigwang from the Beopcheonsa Temple Site in Wonju has been transferred from place to place and reassembled several times since it was built. In particular, overall dismantling and repair was carried out in 1957 to restore parts damaged by bombing during the Korean War. Documented information on the repair process and materials used at that time does not exist. However, various types of metal materials used for this stupa have been identified during conservation work. Besides clamps anchor bolts, 9mm-thick circular rebars were mainly used for joining the parts of this stupa, while circular rebars and wires of various thicknesses were used for joining the parts with mortar restoration materials. Although deformed bars are typically used for stone pagodas classified as architectural structures, smooth circular rebars were used in this case. In terms of restoration using mortar, material shapes were transformed, bound alternately, and twisted irregularly to improve bonding strength and coherence in order to insert restoration materials and to bolster structural weaknesses. In addition, metallographic analysis showed the material to be hypo-eutectoid steel with low carbon content. Many non-metallic inclusions in the shape of drops of different sizes were included, which do not affect the whole elemental composition due to the very small quantities involved. Qualitative and EPMA analysis of Mn and S, which were not identified by SEM-EDS area analysis, established an even distribution of MnS in crystal grains of the microstructure, regardless of the shape of the samples. It is presumed that secondary homogenization and softening might have been conducted after manufacturing to facilitate the working process. Furthermore, in consideration of properties indicating that the thinner the steel is, the less carbon content contained and the greater the elasticity and elongation, it is judged that restoration work was ordered.